Haglund's Deformity Clinical Trial
Official title:
Functional Follow-up After Endoscopic Calcaneoplasty for Haglund's Deformity
Isokinetic muscle strength test implemented by the Biodex system is a method used for evaluating muscle function that has been applied clinically in the field of sports and rehabilitation medicine. However, information on its application on Haglund's deformity remain insufficient. Therefore, the present study is designed to examine the effectiveness of the muscle strength test using the Biodex system in evaluating the recovery of athletic capacity in patients with Haglund's deformity following endoscopic surgery.
Patients. A retrospective (medical records), level 3 evidence study was designed to evaluate
the outcomes of patients who underwent endoscopic surgery for Haglund's deformity. The
present study was approved by the Peking University Third Hospital's ethics committee.
Written informed consent was obtained from all patients, parents or guardians of the patients
prior to the present study. The rights of the patients were protected.
Diagnosis. Patients were designed to be diagnosed based on subjective complaints, combined
with clinical and radiological examinations. Radiological measurements for this disease
include the Fowler-Phillip angle, calcaneal pith angle, parallel pitch lines, Chauveaux-Liet
angle and the X/Y ratio.
;