View clinical trials related to Haemodialysis.
Filter by:The aim of the study is to investigate pulmonary hemodynamics at rest and during exercise in patients before and after kidney transplantation.
The investigators purpose is to research the impact of the simultaneous use of a new dialysis membrane with higher permeability for medium and protein bound uraemic toxins (medium cut-off dialysis membrane Theranova®) combined with diet modification to reduce the level of inflammation in chronic dialysis patients. The investigators hypothesize that the use of a medium-cut off dialysis membrane and dietary modification work synergistically and cause a significant and clinically meaningful reduction in inflammation levels compared to on-line hemodiafiltration with a high-flux dialysis membrane.
The study will compare achieved levels of protein-bound uremic toxins with dialysis using a medium cut-off membrane compared to the treatment by online haemodiafiltration with a high-flux dialysis membrane. In the second phase of the study dietary fiber and short-chain fatty acid intake will be increased to verify a possible additional reduction in the levels of protein bound uremic toxins.
The purpose of this study is to evaluate the INR value of hemodialyzed patient coagulation state (prothrombin time) measured inside the therapeutical zone and thanks to a portable monitor. The values obtained at the point of care will be compared to the standard biological assessment.
The requirements for haemodialysis are increasing. There is now acceptance that the most durable AV fistulae are those created from the patients own veins. Use of the radiocephalic arteriovenous fistula as an autologous vascular access dates back to the 1960's. (Brescia MJ, Cimino JE. Appel K, Hurwich BJ. Chronic hemodialysis using venipuncture and a surgically created arteriovenous fistula. N Engl J Med 1966; 275: 1089 - 1092.) Once established, it has good long term survival and a low complication rate. However, the success rate at creation of a useable AV fistula are not good. In a meta-analysis published in 2005, the primary failure rate of a radiocephalic fistula was 15.3% and the primary and secondary patency rates were 62.5% and 66.0% at one year. (Rooijens PPGM, Tordoir JHM, Stijnen T, Burgmans JPJ, Smet AAEA and Yo TI. Radiocephalic wrist arteriovenous fistula for hemodialysis: meta-analysis indicates a high primary failure rate. Eur J Vasc Endovasc Surg 2004; 28, 583-589). Reasons for this are multiple but it appears as though the main determinants are the quality of the patients veins and the technical skill of the surgeon. Low patency rates are also seen in females and those with small veins and arteries. Creating an anastomosis between a small vein and artery is technically challenging. This is traditionally preformed with a continuous prolene suture. Recently, Medtronic have been marketing the U Clip Anastomotic Device. This is a self closing devise which could be called a vascular clip. Reported advantages of this clip include better patency rates and faster operations. However, to our knowledge there is no randomised evidence to support this with regards to AV fistulas. The vascular anastomosis originally developed by Alexis Carrel used interrupted sutures. Over time this was replaced by a continuous suture technique which was felt to be quicker and had similar patency rates. However, microvascular, paediatric and neurovascular surgeons have shown that there are advantages to an interrupted technique. (Hattori H, Killen DA, Green JW. Influence of suture material and technic on patency of anastomosed arteries of less than 1.5mm. Am Surg. 1970; 36: 352 - 354. Cobbett JR. Microvascular surgery. Surg Clin N Am. 1962; 47: 521.). The reasons for the improved patency with interrupted anastomoses are firstly increased anastomotic compliance and flow rate and secondly elimination of the pursestring effect and puckering seen with continuous sutures. In a prospective but non randomised study to compare interrupted U clips with historical published results, the patency rate of coronary anastomoses was 100% at 6 months using the U clips compare to a patency rate of 90 -100% in the published series. (Wolf RK, Alderman EL, Caskey MP et al. Clinical and six month angiographic evaluation of coronary arterial graft interrupted anastomoses by use of a self closing clip device: a multicentre prospective clinical trial. J Thorac cardiovasc Surg 2003; 126(1): 168 - 178.) Reports from single centres have concluded that the U Clips offer the opportunity to create superior interrupted anastomoses for AV fistula, even in patients who would otherwise be considered poor candidates for fistula creation. (Ross JR. Creation of native arteriovenous fistulas with interrupted anastomoses using a self closing clip device - one clinics experience. Journal of vascular Access 2002; 3: 140 - 146). In this report with small numbers, the radiocephalic fistulas had an 8 week maturation rate of 93%. Of the 28 patients having a radiocephalic fistula, 10 had veins of between 1.0 - 1,5mm diameter. The aim of this pilot study will be to assess if there is a clinical difference in the maturation rates of autologous AV fistulae when a clipped anastomosis is compared to a conventional prolene anastomosis.