Glaucoma Clinical Trial
Official title:
Automated Applanation Tonometry
Goldmann Applanation Tonometry (GAT) is considered the clinical gold standard for eye pressure measurements and yet it is known to be a subjective measurement with limited repeatability and limited portability. The purpose of this study is to develop an automated and objective method for performing applanation tonometry using standard ophthalmic equipment as well as using 2 portable prototypes.
This is a prospective study. Patients presenting for their scheduled eye appointments will be recruited by verbal communication. Following informed consent, intraocular pressure (IOP) measurements will be made by the following 3 upright methods and 1 supine measurements: 1. Standard Goldmann Applanation Tonometry (GAT): this is the standard method for IOP measurement in clinical practice. The eye is given topical fluorescein/anesthetic, the GAT prism contacts the eye while the observer looks through the slit lamp machine ocular using blue light illumination to visual the applanation mires. The GAT dial is adjusted until mire alignment is achieved and the IOP measurement is read off the GAT dial. 2. Fixed force GAT: From the patient perspective, this method will feel identical to the standard GAT. The eye is given topical fluorescein/anesthetic. The GAT dial is set at 1.8 or 2.0, a C-MOS camera is connected to one of the oculars of the slit lamp machine and under blue light illumination, the GAT prism contacts the eye while the CMOS camera makes a video of the mire appearance through the ocular. The diameters of the recorded mire images are measured and the IOP is calculated based on the mire diameter. A similar method using an iPod touch camera has been previously published by this PI (1). 3. Upright applanating prototype: With this prototype, an applanating prism (custom manufactured with medical grade acrylic in an ISO-13485 certified facility) is attached to a fixed-force spring that creates a force equivalent to 1.8 or 2.0 on the GAT dial. Blue LED lights on the prototype are used to create the blue illumination similar to the blue light used in clinical practice on the slit lamp or Perkins tonometer. A C-MOS camera is aligned with the GAT prism to image the applanation mires. The eye is given topical fluorescein/anesthetic. Like fixed-force GAT, the GAT prism contacts the eye while the CMOS camera makes a video of the mire appearance. The diameters of the recorded mire images are measured and the IOP is calculated based on the mire diameter. The order of the above 3 measurements will be randomized. The 4th measurement will be made with the patient in the supine position. Here, the subject will be reclined in our standard clinical exam chair until the iris plane is parallel to the ground. 4. Supine applanating prototype: With this method, a 5 gram clear acrylic cylinder (custom manufactured with medical grade acrylic in an ISO-13485 certified facility) is aligned with the lens of the CMOS camera and the distal tip of the cylinder is illuminated with blue light using an LED similar to the blue light used in clinical practice on the slit lamp or Perkins tonometer. The eye is given topical fluorescein/anesthetic. While the CMOS camera is recording, the 5 gram weight will rest upon the eye and circular applanation mires are recorded. The diameters of the recorded mire images are measured and the IOP is calculated based on the mire diameter. A similar method using an iPhone 6 camera has been previously published by this PI (2). The clear cylinder in this study is the same as that used in this prior study. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT06000865 -
Glaucoma Rehabilitation With Action viDeo Games and Exercise - GRADE
|
N/A | |
Recruiting |
NCT06278597 -
Automatic Evaluation of the Anterior Chamber Angle Width by a New Non-contact Optical Device
|
N/A | |
Active, not recruiting |
NCT04271709 -
Manhattan Vision Screening and Follow-Up Study (NYC-SIGHT)
|
N/A | |
Recruiting |
NCT03274024 -
The Asia Primary Tube Versus Trab (TVT) Study
|
N/A | |
Completed |
NCT04552964 -
Assessment of the Impact of an add-on and Its Smartphone Application on the Daily Management of Glaucoma
|
N/A | |
Recruiting |
NCT01957267 -
Functional and Structural Imaging for Glaucoma
|
||
Active, not recruiting |
NCT04624698 -
iStent Inject New Enrollment Post-Approval Study
|
N/A | |
Completed |
NCT04020705 -
The Efficacy of Citicoline in Eyedrops (OMK1) in Reducing the Progression of Glaucoma
|
N/A | |
Completed |
NCT03150160 -
Additive Effect of Twice-daily Brinzolamide 1%/Brimonidine 0.2%Combination as an Adjunctive Therapy to Travoprost in Patients With Normal Tension Glaucoma
|
Phase 4 | |
Not yet recruiting |
NCT05581498 -
Glaucoma Exercise as Medicine Study (GEMS).
|
N/A | |
Recruiting |
NCT02921568 -
Side-by-Side Comparison of P200TE and Spectral OCT/SLO on Diseased Eyes
|
N/A | |
Active, not recruiting |
NCT02901730 -
Clinical Study of LPI With Different Laser Wavelengths
|
N/A | |
Completed |
NCT02955849 -
A Trial of China Laser and Surgery Study Glaucoma in Rural China
|
Early Phase 1 | |
Recruiting |
NCT02554214 -
Pilot Clinical Trial on a New Adjustable Glaucoma Drainage Device
|
N/A | |
Recruiting |
NCT02471105 -
Investigation of IOP and Tolerability of Bimatoprost 0.01% and Tafluprost Unit Dose Preservative Free 15 Microgram/ml
|
Phase 4 | |
Active, not recruiting |
NCT02390284 -
Stop Retinal Ganglion Cell Dysfunction Study
|
Phase 3 | |
Completed |
NCT02246764 -
Study of Netarsudil (AR-13324) Ophthalmic Solution in Patients With Glaucoma or Ocular Hypertension
|
Phase 3 | |
Completed |
NCT02628223 -
180 Degree vs. 360 Degree Selective Laser Trabeculoplasty as Initial Therapy for Glaucoma
|
N/A | |
Completed |
NCT02390245 -
Philadelphia Telemedicine Glaucoma Detection and Follow-Up Study
|
N/A | |
Completed |
NCT02520674 -
Glaucoma Screening With Smartphone Ophthalmology
|
N/A |