Clinical Trials Logo

Clinical Trial Summary

To determine the safety and efficacy of Kahook dual blade over Trabectome in lowering intraocular pressure in glaucoma patients. Glaucoma surgery will be performed in conjunction with cataract surgery. The investigators hypothesize that the Kahook dual blade is as effective as Trabectome in lowering intra-ocular pressure (IOP), and as safe with a similar rate of post-operative complications such as hyphema.


Clinical Trial Description

Trabectome is a type of Minimally Invasive Glaucoma Surgery (MIGS) where the Trabectome handpiece tip uses electrical current to cauterized and remove a strip of trabecular meshwork and the roof of Schlemm's canal to ease the outflow of aqueous. Kahook Dual Blade (KDB) procedure is another type of MIGS where the dual blade is used to remove the trabecular meshwork and Schlemm's canal roof to increase the aqueous outflow but without any cauterization. Preclinical studies have evaluated the clinical outcome of Trabectome over KDB. Though Trabectome helps to lower IOP, it may remove only a portion of trabecular meshwork and possibly cause damage to surrounding tissue with leaflets of residual remaining tissue that may cause blockage of aqueous drainage. Unlike Trabectome, the KDB removes blocks of trabecular meshwork with no residual tissue leaflets, low rate of fibrosis, no damage to the surrounding tissue and lower cost. However, research studies have shown that although the Trabectome and KDB have different surgical techniques and both have surgical related risks as in any glaucoma surgery, the post-surgical clinical outcome and safety profile of Trabectome could be favorable to the KDB technique. Few studies have evaluated the clinical outcome of Trabectome over Trabeculectomy, while few other studies evaluated Trabectome over phaco-trabectome. Some studies evaluated the clinical outcome of Trabectome alone while other studies assessed the outcome of KDB alone. Some other studies compared KDB with iStent while another study compared Trabectome versus KDB in porcine eye perfusion model. Studies have also shown that Trabectome, when combined with phaco has a higher success rate than Trabectome alone. However, due to the infancy of KDB procedure, there are no robust prospective comparison studies comparing the clinical outcome of KDB over Trabectome when combined with phacoemulsification. The aim of the study is to systematically compare the clinical outcomes of KDB over Trabectome in treating glaucoma ;


Study Design


Related Conditions & MeSH terms


NCT number NCT03894631
Study type Interventional
Source State University of New York at Buffalo
Contact
Status Active, not recruiting
Phase N/A
Start date March 6, 2019
Completion date January 31, 2024

See also
  Status Clinical Trial Phase
Recruiting NCT06000865 - Glaucoma Rehabilitation With Action viDeo Games and Exercise - GRADE N/A
Recruiting NCT06278597 - Automatic Evaluation of the Anterior Chamber Angle Width by a New Non-contact Optical Device N/A
Active, not recruiting NCT04271709 - Manhattan Vision Screening and Follow-Up Study (NYC-SIGHT) N/A
Recruiting NCT03274024 - The Asia Primary Tube Versus Trab (TVT) Study N/A
Completed NCT04552964 - Assessment of the Impact of an add-on and Its Smartphone Application on the Daily Management of Glaucoma N/A
Recruiting NCT01957267 - Functional and Structural Imaging for Glaucoma
Active, not recruiting NCT04624698 - iStent Inject New Enrollment Post-Approval Study N/A
Completed NCT04020705 - The Efficacy of Citicoline in Eyedrops (OMK1) in Reducing the Progression of Glaucoma N/A
Completed NCT03150160 - Additive Effect of Twice-daily Brinzolamide 1%/Brimonidine 0.2%Combination as an Adjunctive Therapy to Travoprost in Patients With Normal Tension Glaucoma Phase 4
Not yet recruiting NCT05581498 - Glaucoma Exercise as Medicine Study (GEMS). N/A
Recruiting NCT02921568 - Side-by-Side Comparison of P200TE and Spectral OCT/SLO on Diseased Eyes N/A
Active, not recruiting NCT02901730 - Clinical Study of LPI With Different Laser Wavelengths N/A
Completed NCT02955849 - A Trial of China Laser and Surgery Study Glaucoma in Rural China Early Phase 1
Recruiting NCT02554214 - Pilot Clinical Trial on a New Adjustable Glaucoma Drainage Device N/A
Recruiting NCT02471105 - Investigation of IOP and Tolerability of Bimatoprost 0.01% and Tafluprost Unit Dose Preservative Free 15 Microgram/ml Phase 4
Active, not recruiting NCT02390284 - Stop Retinal Ganglion Cell Dysfunction Study Phase 3
Completed NCT02628223 - 180 Degree vs. 360 Degree Selective Laser Trabeculoplasty as Initial Therapy for Glaucoma N/A
Completed NCT02520674 - Glaucoma Screening With Smartphone Ophthalmology N/A
Completed NCT02390245 - Philadelphia Telemedicine Glaucoma Detection and Follow-Up Study N/A
Completed NCT02246764 - Study of Netarsudil (AR-13324) Ophthalmic Solution in Patients With Glaucoma or Ocular Hypertension Phase 3