Clinical Trials Logo

Clinical Trial Summary

Real-time continuous glucose monitoring (CGM) systems provide users with information about current glucose levels and alert the patient before the upper or lower glucose threshold is reached or when glucose levels change rapidly. Hence, glycaemic excursions can be early identified and accordingly adapted by behavioural change or pharmacologic intervention. Randomized controlled studies adequately powered to evaluate the impact of long-term application of real-time CGM systems on the risk reduction of adverse obstetric outcomes are missing.


Clinical Trial Description

Intervention: Device description The Dexcom G6 intended use is for the management of diabetes in persons aged 2 years and older. The Dexcom G6 System is intended to replace fingerstick blood glucose testing for diabetes treatment decisions. Interpretation of the Dexcom G6 System results should be based on the glucose trends and several sequential readings over time. The Dexcom G6 System also aids in the detection of episodes of hyperglycemia and hypoglycemia, facilitating both acute and long-term therapy adjustments. The Dexcom G6 System can be used alone or in conjunction with these digitally connected medical devices for the purpose of managing diabetes. The system consists of a sensor, transmitter, receiver, and mobile app. The sensor is a small, flexible wire inserted into subcutaneous tissue where it converts glucose into electrical current. The sensor incorporates an interferent layer that minimizes the effect of potential electroactive interferents, such as acetaminophen, by preventing it from reaching the sensor wire surface. The benefit of this interferent layer in blocking the effects of acetaminophen prevents falsely high glucose readings. Thus, users may ingest acetaminophen while wearing the G6 CGM system. The transmitter, which is connected to the sensor and worn on the body, samples the electrical current produced by the sensor and converts the measurement into a glucose reading using an onboard algorithm. The receiver and/or the app displays the glucose reading along with a rate of change arrow and a trend graph. Additionally, the receiver and/or app issues alarms and alerts to notify the patient of glucose level changes and other important system conditions. The app provides the additional capability to share data with "followers" using the Dexcom Share service. The receiver can be put into a blinded mode using CLARITY® software. In this mode, users are unable to see the CGM data or receive CGM alerts. CGM Ancillary Devices Dexcom CLARITY® is an accessory to users of the Dexcom CGM system. It is a software program that allows the transfer of glucose data from the CGM system to Dexcom remote servers for data management to allow use of the CGM data by the user and study clinicians. Target ranges of 60 to 140 mg/dl [3.3 to 7.8 mmol/l] will be set and the patients will be introduced in the use of alarm settings. Both participants and study sites will use CLARITY® to transfer glucose data between user and study site, whether CGM is used in blinded or real-time mode. A CLARITY® mobile app can be used for retrospective review of glucose data on the smart device and can also be set up to allow receipt of push notifications of CGM data facilitating weekly data review. For all patients (intervention and control group) an anonymized CLARITY® account will be created by using a sequential study number which is allocated at randomization (sex will be female and birth date for each account will be set to 1.1.1990 for all accounts). 1. For participants that have a supported phone, the G6 CGM app will be installed on participant's smart phone. 2. An anonymized CLARITY® mobile account will be set up and linked to the research site. 3. Participants will use CGM data for their diabetes management. 5. A high alert threshold will be set at 140 mg/dl [7.8 mmol/l]. Low alert threshold and urgent low soon alerts will be turned off. If participants require insulin, the low alert will be turned on and the threshold set at 65 mg/dl [3.6 mmol/l]. In addition, the urgent low alert (55 mg/dl [3.1 mmol/l]), the urgent low soon alert (when glucose levels are falling fast and will be below 55 mg/dl [3.1 mmol/l] in less than 20 min) as well as alerts for rise and fall rate (3 mg/dl [0.17 mmol/l]) in addition to alerts for signal loss and no readings for more than 20 min will be enabled. 6. Participants with applicable smart phones may have CLARITY® push notifications on the CLARITY® mobile app about weekly time in range comparison enabled during the study. 7. For app users, the "Share and Follow" functionality will be discussed and encouraged (i.e. the study participants are able to invite followers to review their glucose levels). 8. For participants using the receiver only, the receiver will be downloaded into the CLARITY® clinic account at each visit. 9. For participants using real-time CGM data summary will be downloaded for documentation at V3 and V4 (between 36+0 and 38+6) as well as after delivery (VPP1) 10. The research team will review the CGM in CLARITY® to inform lifestyle and therapy recommendations. 11. The Dexcom G6 system will not be calibrated during the study period. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT03981328
Study type Interventional
Source Medical University of Vienna
Contact Christian Göbl, MD, PhD, MSc
Phone +43660 6534828
Email christian.goebl@meduniwien.ac.at
Status Recruiting
Phase N/A
Start date August 26, 2020
Completion date December 2023

See also
  Status Clinical Trial Phase
Recruiting NCT05081037 - Integrated Hyperglycaemia Incentivised Postnatal Surveillance Study (I-HIPS) N/A
Active, not recruiting NCT03249896 - Web/Smartphone-based Lifestyle Coaching Program in Pregnant Women With Gestational Diabetes N/A
Terminated NCT03749889 - Low Carb vs Normal Carb in Pregnancy N/A
Completed NCT03859193 - Education Nutritional Video for Gestational Diabetics N/A
Recruiting NCT05037526 - Utility of Real Time Continuous Glucose Monitoring in the Care of Gestational Diabetes Versus Standard Care in Pregnancy Outcomes N/A
Completed NCT06178250 - Placenta, Fetal Liver, Sectional Ductus Venosus Volumes Examined by Three-dimensional Ultrasound in the Second Trimester N/A
Not yet recruiting NCT06310356 - Continuous Glucose Monitoring for Women With Gestational Diabetes N/A
Recruiting NCT02590016 - Glucose Control During Labour in Gestational Diabetes Mellitus With Insulin Treatment: A Randomized Controlled Trial Phase 4
Withdrawn NCT01947699 - Glycemic Profile in Women With Gestational Diabetes Treated With Glyburide Phase 4
Not yet recruiting NCT00883259 - Metformin and Gestational Diabetes in High-risk Patients: a RCTs Phase 4
Recruiting NCT03008824 - Micronutrients in Pregnancy as a Risk Factor for Diabetes and Effects on Mother and Baby N/A
Active, not recruiting NCT01340924 - Relationship Between Gestational Diabetes and Type 2 Diabetes
Completed NCT00534105 - Lipid Metabolism in Gestational Diabetes N/A
Recruiting NCT00371306 - Comparison of Glucovance to Insulin for Diabetes During Pregnancy N/A
Completed NCT03388723 - Intergenerational Programming of Diabesity in Offspring of Women With Gestational Diabetes Mellitus
Recruiting NCT04521712 - Postpartum Glycemia in Women at Risk For Persistent Hyperglycemia N/A
Enrolling by invitation NCT03307486 - Gestational Diabetes: a Cohort Study N/A
Active, not recruiting NCT03301792 - Group Versus Traditional Prenatal Care for Diabetes N/A
Enrolling by invitation NCT05603793 - YoUng Adolescents' behaViour, musculoskeletAl heAlth, Growth & Nutrition
Completed NCT03669887 - Lifestyle Modification to Improve Diet in Women With GDM N/A