NCT ID: NCT05979129 Recruiting - Obese Clinical Trials

Gastric Insufflation During Facemask Ventilation at Different Levels of End-expiratory Pressure in Obese Patients

Start date: August 6, 2023
Phase: N/A
Study type: Interventional

Gastric insufflation occurs when the inspiratory pressure exceeds the lower esophageal sphincter pressure. Thus, it is desirable to avoid excessive positive pressure during mask ventilation after induction of anesthesia and keeping the inspiratory pressure <15-20 cmH2O.In patients with obesity the lower compliance of the respiratory system usually requires higher inspiratory pressures to maintain adequate ventilation making these patients more prone to gastric insufflation. This high risk of gastric insufflation can be aggravated by the use of positive end-expiratory pressure (PEEP) which is recommended to avoid lung atelectasis. The application of PEEP during mask ventilation increases the risk of gastric insufflation as it reduces the pressure threshold at which gastric insufflation occur The optimum ventilatory strategy during mask ventilation should achieve the balance between adequate lung ventilation and avoiding gastric insufflation. In obese patients, it is not clear whether the use of PEEP during mask ventilation would increase the risk of gastric insufflation or not. We hypothesize that using zero end-expiratory pressure (ZEEP) or low PEEP during mask ventilation would reduce the risk of gastric insufflation in comparison to high PEEP.

NCT ID: NCT05832554 Recruiting - Clinical trials for Gastric Insufflation

Comparison of the Effects of Nasal and Oral Airway Use on Gastric Insufflation

Start date: May 1, 2023
Phase: N/A
Study type: Interventional

The goal of this clinical trial is to compare the effects of nasopharyngeal and oropharyngeal airway on gastric insufflation in patients undergoing general anesthesia and expected difficult mask ventilation. The main questions it aims to answer are: - Is there a difference between the presence of gastric insufflation in the use of nasopharyngeal and oropharyngeal airways? - Is there a difference between the antral area sizes measured before and after ventilation After general anesthesia induction, nasopharyngeal or oropharyngeal airway will be placed in participants and real-time ultrasonographic gastric antral area imaging will be performed during mask ventilation. Researchers will compare the effects of nasopharyngeal and oropharyngeal airway use on gastric insufflation.

NCT ID: NCT05020548 Recruiting - Clinical trials for Gastric Insufflation

Ventilation and Gastric Insufflation During Three Levels of Inspiratory Pressure During Mask Ventilation

Start date: September 9, 2021
Phase: N/A
Study type: Interventional

Pulmonary aspiration of gastric contents is one of the leading causes of general anesthesia-related mortality. Gastric insufflation during positive pressure mask ventilation increases the gastric volume, and consequently the risk of regurgitation. Thus, positive pressure mask ventilation should be avoided during rapid sequence induction of anesthesia when full-stomach is suspected (e.g. inadequate fasting hours, gastrointestinal obstruction, delayed gastric emptying, and lower esophageal disease) Although avoidance of positive pressure mask ventilation during induction would potentially minimize the risk of aspiration, this would lead to rapid hypoxia . Hence, finding a proper regimen for mask ventilation would avoid hypoxia which might be serious in high-risk patients. Pressure-controlled face mask ventilation previously proved to be the least regimen to cause gastric insufflation in comparison to manual, and volume-controlled mask ventilation during induction of anesthesia. Later, a pressure of 15 cmH2O during face mask ventilation had been reported optimum to achieve the balance between adequate ventilation and reduced gastric insufflation in non-paralyzed patients. This finding was not yet replicated in paralyzed patients who represent the majority of population who receive mask ventilation during induction of anesthesia. We hypothesize that in paralyzed patient, the optimum pressure during face mask ventilation might be lower than the pressure which was previously reported in non-paralyzed patients. However, no studies to the best of our knowledge had confirmed this hypothesis. Gastric insufflation was previously evaluated using auscultation with stethoscope, microphone placed in the epigastric area, or esophageal manometry. Recently, gastric antrum ultrasound was used successfully to gastric insufflation in real time by measuring the cross sectional area of gastric antrum before and after face mask ventilation. This newly developed method is more sensitive than the auscultatory method and less invasive than esophageal manometry method.

NCT ID: NCT04964882 Not yet recruiting - Clinical trials for Gastric Insufflation

Gastric Insufflation During Positive Pressure Ventilation

Start date: July 20, 2021
Phase: N/A
Study type: Interventional

Effect of peak inspiratory pressure on the gastric insufflation is evaluated using ultrasonography during face mask ventilation in obese adults. Effect of facial mask holding techniques on the gastric insufflation is also evaluated.

NCT ID: NCT02097771 Recruiting - Clinical trials for Gastric Insufflation

Gastric Insufflation and Laryngeal Mask Airway

Start date: November 2014
Phase: N/A
Study type: Interventional

Comparison of the incidence of gastric insufflation between two kinds of laryngeal masks airways: LMA SupremeTM vs Ambu AuraOnceTM

NCT ID: NCT01652924 Recruiting - Clinical trials for Gastric Insufflation

Efficacy of Mechanical Ventilation With Facial Mask to Reduce Gastric Insufflation

Start date: May 2012
Phase: N/A
Study type: Interventional

The purpose of this study is to determine whether mechanical ventilation with facial mask during induction anesthesia in the population of 1month to 14years is associated with less risk of gastric insufflations as compared with manual ventilation.