Gait Analysis Clinical Trial
Official title:
Feasibility of Wearable Sensors to Determine Gait Parameters
Hypotheses:
• A wearable sensor system can be used to accurately monitor three common gait parameters:
gait speed, stride length, and torso motion.
Objectives:
This study will examine the feasibility of using wearable sensors to monitor common gait
parameters: gait speed, stride length and torso motion. A wearable sensor system of 8
commercially available inertial measurement units (IMU) will be composed. These sensors will
work in unison to monitor the gait parameters.
Technical Objectives
- Gather information on commercially available IMUs
- Use computer software to monitor and record data from IMUs
- Develop an algorithm that can monitor volunteer gait speed, stride length and torso
motion
- Develop a graphical algorithm that compares healthy patient data to potential mild
traumatic brain injury (mTBI ) candidates
- Determine if there is a potential for mTBI determination using the wearable sensors
- Accurately validate the wearable sensor system to the gait parameters measured using a
Vicon motion analysis system
This study will examine the feasibility of using wearable sensors to monitor common gait
parameters. A sensor system consisting of 8 wearable inertial measurement units (IMU) that
include accelerometers, gyroscopes and magnetometers will be examined. These sensors will be
programmed to work in unison to monitor gait parameters. The wearable sensor suite will have
the capability to collect and store gait parameter data. The size and weight of each sensor
should be similar to a standard metal wrist watch. The sensor suite will monitor three gait
parameters: gait speed, stride length, and torso motion. These gait parameters are important
for monitoring and detection of mild traumatic brain injury and as well as other
neurological and vestibular disorders.
The wearable sensor suite will have the following design parameters:
- Devices must be able to both stream data real-time and record data onboard for later
transfer to a computer.
- Data must be processed using a software analysis package such as MATLAB®
- Device must be no heavier than the size of a metal wrist watch
- Device must be easily put on and be easily operated by clinicians and users
- Device must have a battery life of greater than 4 hours The wearable sensor suite will
then be validated using an eight camera Vicon infrared optical capture motion analysis
system for comparison. Ten healthy volunteers will be asked to complete four different
types of gait trials 5 times for each trial type while being monitored by the Vicon
motion analysis system and the wearable sensor system.
The types of gait trials will be the following:
- Walk down a 20 ft path at self-selected normal stride length and cadence
- Walk down a 20 ft path with increased stride length while decreasing gait speed
- Walk down a 20 ft path with increased stride length while increasing gait speed
- Walk down a 20 ft path with decreased stride length while decreasing gait speed
- Walk down a 20 ft path with decreased stride length while increasing gait speed
;
Observational Model: Case Control, Time Perspective: Prospective
Status | Clinical Trial | Phase | |
---|---|---|---|
Active, not recruiting |
NCT04867148 -
The Prediction and Prevention of Disease by Using Big Data in Motion Analysis
|
N/A | |
Completed |
NCT05538221 -
Reliability of a Gait Analysis System
|
||
Recruiting |
NCT05530213 -
Interlaboratory Reliability of 3D Gait Analysis
|
N/A | |
Recruiting |
NCT05277181 -
Wearable Technology as an Objective Tool for Measuring Running Gait
|
||
Recruiting |
NCT05989113 -
Psychometric Qualities IPAQ-SF
|
||
Not yet recruiting |
NCT05305755 -
Reliability of a Gait Analysis System
|
||
Not yet recruiting |
NCT06264999 -
Robotic Assisted Knee Arthroplasty - Retain the Anterior Cruciate Ligament or Not
|
N/A | |
Completed |
NCT03898544 -
Gait Kinematics After Primary Total Knee Arthroplasty (TKA) Versus Revision TKA
|
||
Completed |
NCT05957783 -
Changes in Upper Limb Kinematics in Children With Cerebral Palsy After Lower Limb Surgery
|
||
Recruiting |
NCT05751408 -
Technical Evaluation of Commercial IMUs Within Clinical Gait Analysis
|
||
Completed |
NCT04788719 -
Pre and Postoperative Gait Analysis of Randomized Patient to 2 Different Cement Fixation Methods
|
N/A | |
Completed |
NCT04791605 -
Gait Pattern Between a Cemented and Non-cemented Femur Stem
|
N/A | |
Withdrawn |
NCT03858556 -
Effect of Chuna Manipulation Therapy on Gait in Patients With Lumbar Disc Herniation
|
||
Completed |
NCT04529642 -
Is the 6-Minute Walking Test Combined With an IMU Useful in Stroke Rehabilitation Assessment?
|
||
Recruiting |
NCT05452655 -
Intensive Multidisciplinary Rehabilitation and Biomarkers in Parkinson's Disease
|
N/A | |
Not yet recruiting |
NCT05855577 -
Motor Function Efficacy of Pharmacological Treatments Targeting Energy Metabolism, in Parkinson's Patients
|
Phase 4 | |
Recruiting |
NCT06253624 -
Gait Pattern Analysis After All Arthroscopic ATFL Repair Surgery
|
N/A | |
Completed |
NCT04230733 -
Pelvis Displacement and Gait Indicators in Patient With Lumbar Disc Herniation
|
||
Recruiting |
NCT06304077 -
Restorative Environments for Gait Therapy With VR
|
N/A | |
Completed |
NCT04434313 -
Treatment of Hemiparetic Gait Impairments Using Telehealth With the Moterum iStride Solution™
|
N/A |