Clinical Trials Logo

Clinical Trial Summary

Gait disturbances can be observed in all age groups, and may be due to different conditions, such as advanced age, stroke, head trauma, spinal cord injury, cerebral palsy, myelomeningocele, among others. The aforementioned gait disorders are associated with an increased risk of falls (which can cause major fractures or head trauma), decreased mobility, loss of independence, cardiovascular pathology, and decreased quality of life. In order to improve a given abnormal gait pattern, an objective assessment of gait is necessary. There are several methods to carry out gait evaluations, like Instrumented Gait Analysis (High cost, time-consuming, qualified professionals needed) and the ones based on observation (limited reliability and validity). An alternative, is the use of video-based systems. SILEMA (Computer System for Gait Study Laboratories in Argentina) is a video-based low-cost gait analysis system that measures temporo-spatial (speed, step length, cadence, stance and swing times) and joint kinematic (Hip, Knee, Ankle) parameters. Its reliability has not been reported yet; thus the primary aim of this study is to determine both the "intra-evaluator" (same evaluator, different sessions) and "inter-evaluator" (same session, different evaluators) reliability.


Clinical Trial Description

Gait disturbances can be observed in all age groups, and may be due to different conditions, such as advanced age, stroke, head trauma, spinal cord injury, cerebral palsy, myelomeningocele, among others. The aforementioned gait disorders are associated with an increased risk of falls (which can cause major fractures or head trauma), decreased mobility, loss of independence, cardiovascular pathology, and decreased quality of life. One of the main objectives of rehabilitation is the improvement of the gait pattern, for which a correct evaluation of it is a necessary condition. Gait analysis is the systematic study of human locomotion, with joint kinematics (description of movement in different planes) and temporo-spatial parameters (speed, cadence, step length, stance and swing times) being variables usually valued and reported. There are several methods for conducting gait assessments. One of them consists of the administration of scales based on observation, which are accessible and simple to execute, but exhibit limited reliability and validity, depending in addition to the previous experience of the observer. The method considered "Gold standard" is the Instrumented Gait Analysis (IGA), from which parameters of kinematics (through optoelectronic cameras and reflective markers), kinetics (through the use of force platforms) and muscle activity (using electromyography) can be obtained.Unfortunately, these systems are not available in most rehabilitation centers, due to the high cost they represent, the need to have highly trained professionals for their use and the long time needed for calibration and post-processing, difficulties that are continuously mentioned in the literature. An alternative to IGA is the use of video-based systems that allow the quantification of temporo-spatial parameters and joint kinematics. One of these systems is SILEMA(Computer System for Gait Study Laboratories in Argentina) which is based on the technique of digital videography. This system exhibits the advantages of being portable, easy to implement and use, and low cost.The purpose of the clinical analysis of gait is usually to differentiate between normal and abnormal patterns, and to assess the change over time or due to an intervention (surgery, orthosis, botulinum toxin, physical therapy, etc.), being necessary in the latter case to make repeated measurements. Usually, to carry out gait evaluations, the patient is asked to perform several "passes", each of them consisting of a free gait through a walkway, at a "self-selected" speed, during a session in which the corresponding information is collected. In healthy subjects, there is usually a variability between repeated measurements (both intra-subject and inter-subject), which occurs at the expense of intrinsic factors (age, height, gait speed, etc.) or extrinsic, caused by methodological errors (experimental error), such as those related to the placement of markers (task carried out by an evaluator, usually a Therapist, or with the processing of a video made by the operator of the software. The consistency or repeatability of the measurements is what is known as reliability. In other words, reliability is a measure of the variability that exists between repeated measurements, and is usually estimated, as recommended, using the intraclass correlation coefficient "ICC" (Relative Reliability) and the standard error of the measure "SEM" (Absolute Reliability). Its determination is very important, since in daily practice it could give information on whether the observed change in a certain parameter of the gait is due to the intervention / evolution of the pathology or to the variability of the measurements. In the context of gait analysis, reliability is typically evaluated "inter-pass" (between several passes of the same subject, in the same session), "intra-operator" (same video evaluated by the same operator at two different times), "interoperator" (same video, different operators), "intra-evaluator" (same evaluator, different sessions) and "inter-evaluator" (same session, different evaluators). To the best of our knowledge, the reliability of SILEMA has not been reported, being the objective of the present study, to determine this metric, with the intention of expanding its use, both for the clinic and for research. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05538221
Study type Observational
Source Centro Integral de Neurologia y Especialidades Afines, Argentina
Contact
Status Completed
Phase
Start date October 20, 2022
Completion date November 4, 2022

See also
  Status Clinical Trial Phase
Active, not recruiting NCT04867148 - The Prediction and Prevention of Disease by Using Big Data in Motion Analysis N/A
Recruiting NCT05530213 - Interlaboratory Reliability of 3D Gait Analysis N/A
Recruiting NCT05277181 - Wearable Technology as an Objective Tool for Measuring Running Gait
Recruiting NCT05989113 - Psychometric Qualities IPAQ-SF
Not yet recruiting NCT05305755 - Reliability of a Gait Analysis System
Not yet recruiting NCT06264999 - Robotic Assisted Knee Arthroplasty - Retain the Anterior Cruciate Ligament or Not N/A
Completed NCT03898544 - Gait Kinematics After Primary Total Knee Arthroplasty (TKA) Versus Revision TKA
Recruiting NCT06304077 - Restorative Environments for Gait Therapy With VR N/A
Completed NCT05957783 - Changes in Upper Limb Kinematics in Children With Cerebral Palsy After Lower Limb Surgery
Recruiting NCT05751408 - Technical Evaluation of Commercial IMUs Within Clinical Gait Analysis
Completed NCT04788719 - Pre and Postoperative Gait Analysis of Randomized Patient to 2 Different Cement Fixation Methods N/A
Completed NCT04791605 - Gait Pattern Between a Cemented and Non-cemented Femur Stem N/A
Withdrawn NCT03858556 - Effect of Chuna Manipulation Therapy on Gait in Patients With Lumbar Disc Herniation
Completed NCT04529642 - Is the 6-Minute Walking Test Combined With an IMU Useful in Stroke Rehabilitation Assessment?
Recruiting NCT05452655 - Intensive Multidisciplinary Rehabilitation and Biomarkers in Parkinson's Disease N/A
Not yet recruiting NCT05855577 - Motor Function Efficacy of Pharmacological Treatments Targeting Energy Metabolism, in Parkinson's Patients Phase 4
Recruiting NCT06253624 - Gait Pattern Analysis After All Arthroscopic ATFL Repair Surgery N/A
Completed NCT04230733 - Pelvis Displacement and Gait Indicators in Patient With Lumbar Disc Herniation
Completed NCT01620021 - Feasibility of Wearable Sensors to Determine Gait Parameters N/A
Completed NCT04434313 - Treatment of Hemiparetic Gait Impairments Using Telehealth With the Moterum iStride Solution™ N/A