NCT ID: NCT06355453 Not yet recruiting - Fetal Monitoring Clinical Trials

Evaluation of the Goldcrest Patch Performance

Start date: April 25, 2024
Phase:
Study type: Observational

The Novii Patch is an accessory to the Novii+ Pod that connects directly to the Novii+ Pod and contains the surface electrodes that attach to the abdomen. The primary objective is to collect Data on Skin Integrity and Patch Adhesion Quality From the Patch After 18 Hours of Wear. The secondary objective is to evaluate fetal monitoring on adult pregnant females greater than 32 weeks gestation and non-pregnant females to collect data on electrical fetal, maternal, and uterine activity.

NCT ID: NCT06135961 Recruiting - Caesarean Section Clinical Trials

Intrapartum Non-invasive Electrophysiological Monitoring

NIEM-II
Start date: November 20, 2023
Phase: N/A
Study type: Interventional

Conventional cardiotocography (CTG) has been used extensively for more than 50 years to monitor the fetal condition during labour, but since the rate of operative deliveries keeps rising, its ability to improve neonatal outcomes is unsatisfactory. A transabdominal non-invasive and wireless alternative which overcomes the shortcomings of conventional methods is electrophysiological CTG (eCTG) monitoring. In eCTG the fetal heart rate (FHR) is measured by fetal electrocardiography (NI-fECG) and uterine activity (UA) by electrohysterography (EHG). Both NI-fECG and EHG have been proven more accurate and reliable than conventional non-invasive methods and are less affected by maternal body mass index (BMI). This study aims to evaluate the mode of delivery, maternal and perinatal outcomes, costs and patient and healthcare professionals perspectives on eCTG monitoring versus the conventional CTG during labour at term with a singleton fetus in cephalic position. The eCTG provides a more accurate assessment of the fetus and the UA, compared to the conventional CTG. This allows for optimization of the contraction pattern during high-risk deliveries. We hypothesize that this will reduce the number of operative interventions and improves perinatal outcome. There are three reasons why an improvement in the contraction pattern by the eCTG can influence our outcomes: 1. EHG can detect excessive UA more accurately. Increased UA is a major risk for fetal distress. In this case, stimulation with oxytocin should be reduced or stopped. More adequate interpretation of FHR, reduced tachysystole and reduced hypertonia is expected to result in fewer instrumented vaginal deliveries and a reduction of caesarean sections due to fetal distress. 2. EHG can demonstrate unorganized UA that needs to be corrected with a higher dose of oxytocin to enhance contraction frequency and efficiency. This can result in a less exhausted uterine muscle, shorter time to delivery, less vacuum deliveries and caesarean sections due to failure of progress. A shorter time to delivery will also result in a reduction of infections and blood loss. 3. Accurate registration of the relation between the contraction and decelerations of FHR, is expected to result in more reliable assessment of the fetal condition. This can result in fewer unnecessary operative deliveries and less unpredictable poor perinatal outcomes.

NCT ID: NCT05938790 Recruiting - Ultrasound Clinical Trials

Point of Care Ultrasound in Obstetric Triage

POCUS
Start date: October 26, 2023
Phase: N/A
Study type: Interventional

The research will find out if using portable ultrasound devices by nurses can make it quicker to get babies from 24 to 32 weeks on the doppler monitor.

NCT ID: NCT05933928 Not yet recruiting - Fetal Monitoring Clinical Trials

The Effect of Simulation-based Electronic Fetal Monitoring Training on Midwifery Students

Start date: September 1, 2023
Phase: N/A
Study type: Interventional

This study was planned to determine the effect of scenario-based high-fidelity electronic fetal monitoring simulation method on midwifery students' self-efficacy-efficacy and situational anxiety levels. The study was planned as a randomized controlled experimental study. This RCT will be administered following the CONSORT 2010 guidelines. Midwifery students will be given information about the introduction of the simulator and the model, the flow chart of the training plan, the content of the training plan, the environment, the locations of the materials. 40 students selected for the intervention group will be given high-fidelity simulator and information on case-based learning will be given to 40 students selected for the training and control group. "State Anxiety Inventory" and "Self-Efficacy-Efficacy Scale" will be applied as a pre-test after the briefing. High-fidelity simulator application training will be applied to the intervention group students, accompanied by a scenario, and case-based learning method will be applied to the control group students. After the training, "State Anxiety Inventory", "Self-Efficacy-Efficacy Scale" and "Satisfaction with Educational Methods Questionnaire" will be administered to all students. Three months after the training, the "State Anxiety Inventory" and "Self-Efficacy-Efficacy Scale" will be administered to the students again.

NCT ID: NCT05863156 Completed - Maternal Health Clinical Trials

Evaluation of the Effects of Different Positions Given During Antenatal Electro-Fetal Monitoring

Start date: December 30, 2021
Phase: N/A
Study type: Interventional

The aim of this study was to examine the effects of different positions given to pregnant women during electro fetal monitoring on maternal and fetal health. The study was conducted in a pregnant follow-up outpatient clinic of a maternity hospital in Istanbul, between December 2021 and January 2023, in a randomized controlled experimental study design with two interventions and a control group. In the study, 60 participants were placed in the right side lying position (intervention 1), 60 participants in the semi-sitting position (intervention 2) and 120 participants in the left side lying position (control group), and the study was completed with a total of 240 pregnant women. According to NST extraction positions, systolic blood pressure and body temperature of the pregnant women were found to have a statistically significant difference between pre-NST extraction, NST extraction time and post-NST extraction positions, time and group-time (p<0.05). It was determined that the difference between the groups was that the semi-sitting position created a significant difference compared to the other position averages. In terms of time, the NST moment made a difference compared to other times. It was determined that the right position made a statistical difference compared to the other position averages in the pulse count. It was found that the semi-sitting position had a statistically significant effect on maternal comfort (t=3.834, p<0.05). It was determined that the semi-sitting position caused an increase of 0.911 on general comfort (β=0.911).

NCT ID: NCT05847790 Recruiting - Fetal Monitoring Clinical Trials

Remote Pregnancy Monitoring to Improve Access

REACTIVE
Start date: May 25, 2023
Phase: N/A
Study type: Interventional

The goal of this clinical trial is to determine the effectiveness of remote nonstress test (NST) compared to in-clinic NSTs in improving fetal testing completion rates. Participants will be randomized to either in-clinic NSTs or use of an FDA-approved remote monitoring belt for their pregnancy monitoring.

NCT ID: NCT05665400 Recruiting - Fetal Monitoring Clinical Trials

A Clinical Study for the Development of a Device (Lovelace) for Antepartum Fetal Monitoring

Start date: July 13, 2022
Phase: N/A
Study type: Interventional

Bloomlife Lovelace FT is a non-invasive, wireless, external measurement system used to measure accelerometer and electrophysiological signals on pregnant women with a singleton pregnancy, by acquiring biopotential signals from abdominal surface electrodes. In this study, Bloomlife Lovelace FT is used to collect the dataset needed for the development of a future product (Bloomlife Lovelace) for the monitoring of fetal heart rate, maternal heart rate and uterine activity.

NCT ID: NCT05510349 Not yet recruiting - Fetal Monitoring Clinical Trials

Prevention of Per-partum Fetal Hypoxia: Measure of Placental Elasticity and Viscosity During Labor

ELASTOLab
Start date: October 2022
Phase: N/A
Study type: Interventional

Fetal heart rate (FHR) monitoring during labor aims to detect fetuses at risk of intrapartum hypoxia in order to accelerate their birth before the constitution of sequelae such as anoxic encephalopathy and cerebral palsy. But the positive predictive value of FHR monitoring is low, and many second-line tests have been proposed but none of them has been proven to be conclusive. Measure of placental elasticity and viscosity during labor could be a new second line test to complete the FHR monitoring. Several studies have shown that placental elasticity is increased in case of gestational diabetes, preeclampsia, or intrauterine growth restriction, but no study has focused on placental elasticity during labor. The investigators hypothesize that placental elasticity and viscosity could reflect the quality of maternal-fetal exchanges during labor, and could help to detect fetus at risk of intrapartum hypoxia. The first aim of this study is to describe the values of placental elasticity and viscosity during different points in the labor: beginning of the labor, beginning of the active phase of the first stage of labor, and passive phase of the second stage of labor. Secondary aims of this study are: to describe the values of placental elasticity and viscosity in case of oxytocin infusion, in case of abnormal FHR, and ex-vivo after placental expulsion. This unicentric observational prospective study will include 150 patients with singleton pregnancy, without pathology, with spontaneous labor at term.

NCT ID: NCT05060172 Completed - Fetal Monitoring Clinical Trials

A Clinical Study for Validating the Equivalence of Bloomlife MFM-Pro to Clinical Standard-of-care for Antepartum Fetal Monitoring

NST
Start date: June 25, 2021
Phase: N/A
Study type: Interventional

Bloomlife has developed a wearable system (Bloomlife MFM-Pro) that can allow fetal monitoring to be conveniently performed in healthcare settings under supervision of a healthcare professional. Bloomlife MFM-Pro is a non-invasive, wireless, external monitoring system used to measure fetal heart rate, maternal heart rate, and uterine activity during antepartum (non-stress) testing on pregnant women with a singleton pregnancy. The purpose of this study is to validate that the Bloomlife MFM-Pro is equivalent to clinical standard-of-care for routine non-stress test (NST) performed at the hospital.

NCT ID: NCT04915131 Completed - Fetal Monitoring Clinical Trials

A Clinical Study for Validating the Equivalence of Bloomlife MFM-Pro to Clinical Standard-of-care for Performing Antepartum Fetal Monitoring

NST
Start date: April 6, 2021
Phase: N/A
Study type: Interventional

Bloomlife MFM-Pro is a non-invasive, wireless, external monitoring system used to measure fetal heart rate and maternal heart rate on pregnant women with a singleton pregnancy, starting from 32 weeks of gestation. The purpose of this study is to validate that the Bloomlife MFM-Pro is equivalent to clinical standard-of-care for fetal heart rate and maternal heart rate when performing antepartum fetal monitoring.