Femoroacetabular Impingement Clinical Trial
Official title:
Prospective Randomized Controlled Study Utilizing the Stryker Hip-Check Software Platform
Accurate femoroplasty has been shown to be critical in achieving success following treatment of femoroacetabular impingement (Matsuda, Schnieder, and Sehgal 2014; Mansor et al. 2018; Larson et al. 2014). Nearly 75% of cases undergoing revision hip arthroscopy do so due to residual femoroacetabular impingement (Ricciardi et al. 2014). Femoroplasty remains one of the most challenging and time-consuming procedures in hip arthroscopy and methods to improve accuracy and optimize time management are essential. The HipCheck system is a navigational tool based on intraoperative fluoroscopy that aims at improving accuracy and efficiency of femoroplasty. The objective of this study is to two-fold. (1) To prospectively compare surgical and (2) radiographic outcomes of patients undergoing femoroplasty with guidance of Stryker's HipCheck system to patients undergoing femoroplasty with conventional fluoroscopic methods.
The purpose of this study is to prospectively compare surgical and radiographic outcomes of patients undergoing femoroplasty with guidance of Stryker's HipCheck system to patients undergoing femoroplasty with conventional fluoroscopic methods. Endpoints: Time from initiation to completion of femoroplasty Accuracy of femoroplasty as determined by: alpha angle on Dunn view and AP view, femoral head offset, and area of over resection and under resection Fluoroscopic exposure (microgray and seconds) Post-operative opioid consumption/medication use Basic design: Randomized Controlled Study Participants: 40 patients 20 patients will undergo femoroplasty with the conventional technique 20 patients will undergo femoroplasty with the HipCheck system Accurate femoroplasty has been shown to be critical in achieving success following treatment of femoroacetabular impingement (FAI).1-3 Nearly 75% of cases undergoing revision hip arthroscopy do so due to residual FAI. Matsuda et al. coined the term "critical corner" to describe residual impingement not resected during routine anterolateral femoroplasty. These residual cam lesions have been shown to lead to inferior outcomes and are commonly implicated in revision hip arthroscopies. These studies and others contributed to the development of the "spherical femoroplasty" as an attempt to minimize residual cam lesions while simultaneously, avoiding over-resection. Femoroplasty remains one of the most challenging and time-consuming procedures in hip arthroscopy and methods to improve accuracy and optimize time management are essential. General Schema of Study Design Overview Patients will be randomly assigned to undergo femoroplasty either with a conventional technique or a navigational method involving the HipCheck system. Preoperatively, the patient will undergo a series of standard radiographs to assess the degree of deformity. At this time, ROM will also be assessed. During surgery time required for femoroplasty as well as total fluoroscopic exposure time, as well as total exposure in microgray will be recorded. At 2 weeks postoperatively patient will undergo a series of standard radiographs to assess accuracy of femoroplasty. Narcotic medication use, pain levels and patient-reported outcome scores (PROs) will be assessed at 2 weeks, 3 months, 6 months, and 12 months postoperatively. A clinical exam will be performed postoperatively at each visit, consisting of hip range of motion (internal/external rotation, flexion, abduction, and adduction) with the patient in the supine position, impingement tests, and gait. Radiographic measurements will be performed using the institutional PACS system as well as ImageJ for surface area calculations. The patients as well as the clinician performing postoperative radiographic calculations will be blinded to method of treatment. The total duration of the study is 1 year and 6 months: Legal contract & IRB review: 8 weeks Patients recruitment/procedure: 8 weeks Follow up period: 1 year Manuscript writing/submission: 8 weeks Data Sources Research resources: Research data will be collected and recorded by study personnel designated by the Investigator. Study Procedures Pre-Operative A series of standard radiographs (Dunn, AP, False profile views) will be taken to understand the severity of the cam-type impingement. A clinical exam including but not limited to the following will be performed: gait (antalgic, Trendelenburg) hip range of motion (internal/external rotation, flexion, abduction, and adduction) with the patient in the supine position; anterior, posterior and lateral impingement tests; painful internal/external snapping test, FABER's test, Modified Resisted Internal rotation test, Ligamentum Teres test. Pre-operative patient-reported outcome scores (PROs) and Visual Analog Pain Scale (VAS) will be taken during screening. The PROs include: mHHS, modified Harris Hip Score; NAHS, Nonarthritic Hip Score; iHOT-12, International Hip Outcome Tool; SF-12M, Short Form 12 Mental; SF-12P, Short Form 12-Physical; VR-12M, Veterans RAND 12-Item Health Survey Mental; VR-12P, Veterans RAND 12-Item Health Survey Physical; and Patient satisfaction (out of 10). Intra-Operative During surgery - time required for femoroplasty as well as total fluoroscopic exposure time, as well as total exposure in microgray will be recorded. Procedural start (at initiation of femoroplasty) and finish (at completion of femoroplasty) time will be recorded for comparative analysis of both groups. Fluoroscopic exposure time and total exposure in microgray will be determined based on total number of shots taken and known duration/microgray exposure of each fluoroscopic shot. Fluoroscopic shot duration/Microgray exposure: mean total fluoroscopy time will be limited to 1.10 minutes or less (52 mGy or less per patient), based on recommendations by Budd et al. 2012 Intraoperative Fluoroscopic Image Acquisition Each patient will be placed in a neutral position to allow for the standardization and comparison with the well-centered, preoperative anteroposterior (AP) pelvic radiographs that are typically used for structural analysis and treatment planning. Once the fluoroscopic image most closely replicates the AP pelvis, the femoral head-neck junction (FHNJ) will be assessed with fluoroscopy, with the leg in 6 different positions and fluoroscopic C-arm in 3 different positions (see table below) that allow for the evaluation of the medial and lateral FHNJ (extension views) and anterior and posterior FHNJ (flexion views). These views will be obtained by rotating the operative distal femur, flexing/extending the operative hip, and/or adducting the operative hip. For all six positions, the angle of rotation will be verified with a Goniometer (Prestige Medical, Northridge, CA). Measurements of the alpha angle will be performed by a single reader on each exported fluoroscopic view (corresponding to the six positions) for every control specimen with the use of the HipCheck System. For the control group the surgeon will review the fluoroscopic images prior to the resection procedure, but without making or reviewing any measurements or analysis (The HipCheck analysis platform will have "alpha angle overlay" turned off, to keep measurements from being displayed). For the HipCheck group the surgeon will review the fluoroscopic images including the HipCheck analysis for each view prior to resection. Hip Arthroscopy (femoroplasty): Femoroplasty will be performed using a 5.5 mm bur. This will be done in combination with the aid of fluoroscopic visualization and HipCheck technology or isolated fluoroscopic visualization, depending on the patient group assignment. The HipCheck system will be used intraoperatively to assist with clinical decision making by assessing and providing feedback on alpha angle and confirming complete bony resection and absence of residual deformity for the test group only. To prevent over- or under resection, HipCheck provides a resection line (spline) for the surgeon to visualize and resect the desired amount, with a target alpha angle of 40 degrees. The control group will not receive intra-operative assistance from the HipCheck software platform. Both arthroscopic and fluoroscopic imaging will be used to identify the cam and aid in resection per the standard hip arthroscopy technique. "Postoperative" Fluoroscopic Image Acquisition At the conclusion of the hip arthroscopy, postoperative fluoroscopy views will be obtained with the same six leg positions. The angle of rotation will be verified with a Goniometer (Prestige Medical, Northridge, CA). The HipCheck tablet and software may be used to capture and later analyze the alpha angle for each of these leg positions for both the control and test groups. Post-Operative At 2 weeks postoperatively patients will undergo a series of standard radiographs (Dunn, AP, False profile views) to assess accuracy of femoroplasty. Measurements will be performed using the institutional PACS system as well as ImageJ for surface area calculations. Accuracy of femoroplasty will be determined by: alpha angle on Dunn, AP views and false profile, femoral head offset, and area of over resection and under resection on AP. The patients as well as the clinician performing postoperative radiographic calculations will be blinded to method of treatment. A post-operative PROs and VAS Pain Score will be taken at 2 weeks, 3 months, 6 months, and 12 months post-operatively. Medication use will be documented in post-op recovery, at 2 weeks, 3months, and 12 months post-operatively. A clinical exam including range of motion assessment will be performed at 2-week, 3-, 6-, and 12-month follow-up visits. Subject Inclusion Criteria Candidates for this study must meet ALL of the following criteria: 1. Patients undergoing hip arthroscopy; aged 18-50 years old. 2. Radiographic evidence of a cam lesion as defined by an alpha angle greater than 60 degrees as measured on the Dunn X-ray. 3. Failure of non-conservative management Subject Exclusion Criteria Candidates will be excluded from the study if ANY of the following apply: 1. Unwilling to participate 2. History of prior hip conditions such as slipped capital femoral epiphysis, Legg-Calvé-Perthes disease, idiopathic avascular necrosis, hip joint trauma, and prior hip surgeries 3. The presence of a concurrent systemic inflammatory arthritis such as rheumatoid arthritis; psoriatic arthritis, ankylosing spondylitis, juvenile idiopathic arthritis, or systemic lupus erythematosus 4. Marked osteoarthritis (Tönnis grade 2 or higher) 5. Subject is considered a part of a vulnerable population 6. Pregnancy in order to avoid: x-rays and the contraindication of lying supine after 20 weeks secondary to pressure on the abdominal aorta Subject Withdrawal Criteria Subjects may voluntarily withdraw from the study at any time for any reason. The Investigator may elect at any time to withdraw a subject from the study for any reason if such a decision is in the subject's best medical interest. If a patient discontinues the study or is withdrawn by the Investigator prior to surgery, the patient will not be counted as a completed subject and an additional subject may be enrolled to achieve the enrollment goal of 40 completed subjects. Data Management Use established data registry and collection methodology. All preoperative and demographic data is collected and inputted into registry preoperatively. Intraoperative data and measurements are collected and inputted at time of surgery. Postoperative radiographic measurements to assess alpha angle and combined femoral offset are made within 3 months postoperatively, using a 2nd independent reader to verify inter- and intra-observer reliability. Intraoperative data and postoperative complications are collected using OBERD system. Risks Generalized risks to surgical procedures are present, which include but are not limited to bleeding, infection, injury to surrounding structures such as blood vessels, nerves, tendons, and bone. In addition, risks specific to hip arthroscopy include those related to hip traction related issues such as numbness and parasthesias to the perineum or soft tissue compression related complications. Lastly, risk to radiation exposure is present, however, it is limited with the use of HipCheck, as continuous fluoroscopy is not needed. Benefits Enhanced verification of intraoperative cam resection via minimal fluoroscopic exposure. In addition, increased accuracy of cam resection with the goals of avoiding over or underresection, will thereby potentially improve patient outcomes following hip arthroscopy. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT01623843 -
Femoroacetabular Impingement RandomiSed Controlled Trial
|
N/A | |
Completed |
NCT03669471 -
Muscular and Functional Performance in FAIS Patients
|
||
Not yet recruiting |
NCT05031390 -
the Horsens Aarhus FemoroAcetabular Impingement Syndrome Training Pilot Study
|
N/A | |
Active, not recruiting |
NCT05025956 -
Senolytic Agent Improve the Benefit of Platelet-Rich Plasma and Losartan
|
Phase 1/Phase 2 | |
Withdrawn |
NCT02674113 -
Regional Anesthesia in Hip Arthroscopy
|
N/A | |
Withdrawn |
NCT02260726 -
Evaluation of Ultrasound for Detecting Hip Impingement
|
N/A | |
Recruiting |
NCT05391204 -
Reproducibility of Strength Testing and Functional Testing of the Hip for the Return to Sport of Patients Activated by a Femoroacetabular Impingement: Comparison Between a Group of Patients and a Group of Healthy Controls
|
N/A | |
Active, not recruiting |
NCT03891563 -
Prospective Evaluation of Sport Activity and the Development of Femoroacetabular Impingement in the Adolescent Hip
|
||
Active, not recruiting |
NCT04069507 -
Healthy Hip Study: Conservative Management for Pre-arthritic Hip Disorders
|
||
Terminated |
NCT03278353 -
Fulfillment of Expectations for Patients With FAI Syndrome
|
N/A | |
Terminated |
NCT03995290 -
3D Modeling to Improve Hip Arthroscopy Outcomes
|
||
Completed |
NCT06082271 -
Comparative, Randomized Study on the Anti-inflammatory and Regenerative Efficacy of a New Medical Device (DM) Based on Hydrolyzed Collagen Peptides in Patients With Femoro-acetabular Impingement Undergoing Hip Arthroscopy
|
N/A | |
Recruiting |
NCT01621360 -
Hip Arthroscopy Versus Conservative Management of Femoroacetabular Impingement
|
N/A | |
Completed |
NCT04980209 -
The Feasibility and Application of Intraoperative Ultrasound to Evaluate Femoral Head Shaping
|
||
Enrolling by invitation |
NCT04988659 -
Analysis of Gene Expression in Femoroacetabular Impingement (FAI)
|
||
Active, not recruiting |
NCT03494660 -
SCP Hip Outcomes Study
|
||
Active, not recruiting |
NCT04822571 -
Investigating the Reliability of Highly Dynamic 3D Motion Analysis Protocol in Adolescence and Adult Males
|
N/A | |
Withdrawn |
NCT02706756 -
Conservative Intervention of Femoroacetabular Impingement Syndrome
|
N/A | |
Completed |
NCT02702661 -
PRCT of FICB vs LAI for Hip Arthroscopy
|
N/A | |
Completed |
NCT01814124 -
Conservative Management of Femoroacetabular Impingement
|
N/A |