Clinical Trials Logo

Clinical Trial Summary

This pilot, prospective, interventional, monocentric, independent, and no-profit clinical trial aims to investigate and evaluate the proportion, acute and chronic characteristics, and outcomes of esophageal thermal injury (ETI) in AF ablation using a high-power, short-duration (HP-SD) setting with contact force (CF) sensing tip ablation catheter in standard clinical practice. The main questions it aims to answer are: - Evaluate the acute proportion of the ETI assessed by the mini-invasive esophagoscopy pre and post-procedure. In addition, clinical evaluations at 3, 6, and 12 months from the procedure are foreseen. - Evaluate the contribution of the factors influencing RF procedure (contact force, impedance, RF power, RF time) on ETI development. - Describe the relationship between the esophageal temperature (continuous monitoring) and ETI development.


Clinical Trial Description

This study aims to estimate the proportion of esophageal thermal injury (ETI) as a result of the AF ablation using a high-power, short-duration (HP-SD) setting with contact force (CF) sensing tip ablation catheter immediately after and at 3, 6, and 12 months from the procedure, as well as describe their characteristics. To be more sensitive and specific in detecting the presence of potentially chronic and progressing ETIs in esophageal ulcers and atrium-esophageal fistula, a minimally invasive esophagogastroscope will be used before (1-7 days) and after (1-3 days) the ablation procedure, with an internal comparison of the lesions observed. In addition, various clinical characteristics of the patients and descriptors of the ablation procedure (such as contact force, impedance, RF power, RF time, esophageal temperature, procedure times, etc.) will be collected and related to the presence of ETI. The principal Medical Devices that will be used: 1. Cardiac Mapping system Ensite X (Abbott Medical), 2. Tip CF sensing catheter TactiFlex (Abbott Medical), 3. High mapping density catheter (HD GRID/Advisor FL, Abbott Medical), 4. Continuous temperature monitoring devices (Esotest Multi/Esotherm 7 poles, FIAB), 5. Video-endoscope EXERA III HDTV dual focus GIF-HQ190 (Olympus). ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05758805
Study type Interventional
Source Quovadis Associazione
Contact Antonio Dello Russo, MD
Phone +39 ?0715965798?
Email antonio.dellorusso@ospedaliriuniti.marche.it
Status Recruiting
Phase N/A
Start date January 8, 2024
Completion date October 2025

See also
  Status Clinical Trial Phase
Recruiting NCT05654272 - Development of CIRC Technologies
Terminated NCT04115735 - His Bundle Recording From Subclavian Vein
Completed NCT04571385 - A Study Evaluating the Efficacy and Safety of AP30663 for Cardioversion in Participants With Atrial Fibrillation (AF) Phase 2
Completed NCT05366803 - Women's Health Initiative Silent Atrial Fibrillation Recording Study N/A
Completed NCT02864758 - Benefit-Risk Of Arterial THrombotic prEvention With Rivaroxaban for Atrial Fibrillation in France
Recruiting NCT05442203 - Electrocardiogram-based Artificial Intelligence-assisted Detection of Heart Disease N/A
Completed NCT05599308 - Evaluation of Blood Pressure Monitor With AFib Screening Feature N/A
Completed NCT03790917 - Assessment of Adherence to New Oral anTicoagulants in Atrial Fibrillation patiEnts Within the Outpatient registrY
Enrolling by invitation NCT05890274 - Atrial Fibrillation (AF) and Electrocardiogram (EKG) Interpretation Project ECHO N/A
Recruiting NCT05266144 - Atrial Fibrillation Patients Treated With Catheter Ablation
Recruiting NCT05316870 - Construction and Effect Evaluation of Anticoagulation Management Model in Atrial Fibrillation N/A
Not yet recruiting NCT06023784 - The Impact of LBBAP vs RVP on the Incidence of New-onset Atrial Fibrillation in Patients With Atrioventricular Block N/A
Recruiting NCT05572814 - Transform: Teaching, Technology, and Teams N/A
Recruiting NCT04092985 - Smart Watch iECG for the Detection of Cardiac Arrhythmias
Completed NCT04087122 - Evaluate the Efficiency Impact of Conducting Active Temperature Management During Cardiac Cryoablation Procedures N/A
Completed NCT06283654 - Relieving the Emergency Department by Using a 1-lead ECG Device for Atrial Fibrillation Patients After Pulmonary Vein Isolation
Recruiting NCT05416086 - iCLAS™ Cryoablation System Post-Market Clinical Follow-up (PMCF) Study N/A
Completed NCT05067114 - Solutions for Atrial Fibrillation Edvocacy (SAFE)
Completed NCT04546763 - Study Watch AF Detection At Home
Completed NCT03761394 - Pulsewatch: Smartwatch Monitoring for Atrial Fibrillation After Stroke N/A