Clinical Trials Logo

Endobronchial Ultrasound clinical trials

View clinical trials related to Endobronchial Ultrasound.

Filter by:
  • Completed  
  • Page 1

NCT ID: NCT04816981 Completed - Lung Cancer Clinical Trials

AI-EBUS-Elastography for LN Staging

AI-EBUS-E
Start date: September 1, 2021
Phase: N/A
Study type: Interventional

Before any treatment decisions are made for patients with lung cancer, it is crucial to determine whether the cancer has spread to the lymph nodes in the chest. Traditionally, this is determined by taking biopsy samples from these lymph nodes, using the Endobronchial Ultrasound Transbronchial Needle Aspiration (EBUS-TBNA) procedure. Unfortunately, in 40% of the time, the results of EBUS-TBNA are not informative and wrong treatment decisions are made. There is, therefore, a recognized need for a better way to determine whether the cancer has spread to the lymph nodes in the chest. The investigators believe that elastography, a recently discovered imaging technology, can fulfill this need. In this study, the investigators are proposing to determine whether elastography can diagnose cancer in the lymph nodes. Elastography determines the tissue stiffness in the different parts of the lymph node and generates a colour map, where the stiffest part of the lymph node appears blue, and the softest part appears red. It has been proposed that if a lymph node is predominantly blue, then it contains cancer, and if it is predominantly red, then it is benign. To study this, the investigators have designed an experiment where the lymph nodes are imaged by EBUS-Elastography, and the images are subsequently analyzed by a computer algorithm using Artificial Intelligence. The algorithm will be trained to read the images first, and then predict whether these images show cancer in the lymph node. To evaluate the success of the algorithm, the investigators will compare its predictions to the pathology results from the lymph node biopsies or surgical specimens.

NCT ID: NCT04718922 Completed - Clinical trials for Endobronchial Ultrasound

Chlorhexidine Mouthrinse Before EBUS-TBNA

CHX_EBUS
Start date: January 20, 2021
Phase: Phase 4
Study type: Interventional

The purpose of this study is to investigate whether chlorhexidine mouthrinse is effective in preventing microbial contamination during endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA).

NCT ID: NCT02713191 Completed - Clinical trials for Endobronchial Ultrasound

Dexmedetomidine vs. Midazolam Sedation for Endobronchial Ultrasound

Start date: March 2016
Phase: Phase 2/Phase 3
Study type: Interventional

The randomized controlled trial will compare efficacy and safety of dexmedetomidine to midazolam for sedation during endobronchial ultrasound