This prospective study will use a self controlled design for 35 eyes. Patients scheduled to undergo routine cataract surgery in at least one of their eyes will have their pre-surgical measurements performed, IOL calculated and surgery planned. Then they will receive insertion of an intracanalicular dexamethasone insert into the inferior punctum. At 2 weeks (+/- 2 days) post-insertion, patients will return for an identical set of measurements. The IOL will be calculated and the surgery planned based on post-insert data. The insert will be removed if present (manually or via saline irrigation). This self controlled design allows for greater control of potential confounders tied to participants' systemic and ocular health.


Clinical Trial Description

Ocular surface optimization is a pre-operative necessity. In cataract surgery patients, an unstable tear film reduces the quality of corneal reflections and therefore can compromise K readings, which in turn can affect the accuracy of IOL calculations and result in suboptimum refractive results. To obtain accurate measurements, patients are routinely pre-treated with a variety of medications and therapies. However, these therapies can take time, which may lead to surgical delays. Steroids can positively impact the stability of the tear film by inhibiting and preventing ocular surface inflammation. Punctal plugs are also widely used for the treatment of dry eye manifestations, by blocking the tear drainage, increasing tear film and eye moisture. Dextenza is a sustained-release dexamethasone intracanalicular insert recently approved by the FDA for pain and inflammation post ophthalmic surgery. It is placed into the canaliculus via the lower punctum and is designed to release steroid medication for 30 days. Previous studies have demonstrated that ocular surface disease affects the reliability of IOL calculations, potentially affecting outcomes. The insert of a punctal plug that can deliver a sustained release of dexamethasone to the eye 2 weeks (+/- 2 days) prior to final preoperative measurements may provide adequate therapy, improving the ocular surface status and, therefore, improve the reliability of IOL selection in patients undergoing cataract surgery, in a comparatively short amount of time, without introducing patient compliance barriers. Pre-surgical measurements, IOL calculations, and surgical plans prior to the insertion of the insert will be compared to measurements, IOL calculations, and surgical plans at 2 weeks following intracanalicular dexamethasone insertion. Surgery will proceed with data from the post-insert measurements. Final refractive outcomes at one month from the second eye surgery will be compared to pre-insert data to determine refractive accuracy. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04530864
Study type Interventional
Source Prism Vision Group
Contact Stanley Oliveira, BSN
Phone (800) 708-8800
Email soliveira@prismvisiongroup.com
Status Not yet recruiting
Phase Phase 4
Start date January 2021
Completion date July 2021

See also
  Status Clinical Trial Phase
Completed NCT03216096 - Assessing Safety and Efficacy of DE-089 Ophthalmic Solution in Patients With Dry Eye Disease Phase 1
Completed NCT05825599 - PMCF Study to Evaluate Performance and Safety of "HPMC-based Eyedrops" Used to Relieve Dry Eye Symptoms N/A
Completed NCT04656197 - The Ocular Microbiome in Patients With Dry Eye Disease
Completed NCT05031806 - Evaluation of the Safety, Tolerability and Efficacy of iNexin™ for the Treatment of the Signs and Symptoms Associated With Dry Eye Disease Phase 1
Completed NCT03688802 - Efficacy of OC-01 Nasal Spray on Goblet Cell and Meibomian Gland Stimulation Phase 2
Completed NCT05213156 - Concentration of Ofloxacin Into the Aqueous Humour of Patients With Dry Eye Disease Phase 4
Completed NCT04548427 - Study to Evaluate the Efficacy and Safety of CKD-352 Phase 3
Completed NCT06176651 - Evaluation of Miebo (Perfluorohexyloctane) Eyedrops in Habitual Contact Lens Wearers Phase 4
Completed NCT02254265 - Phase 2/3 Dose-Ranging Study of the Safety and Efficacy of OTX-101 in the Treatment of Keratoconjunctivitis Sicca Phase 2/Phase 3
Completed NCT00395759 - The Visual Effect of an Investigational Artificial Tear in the Tear Layer. N/A
Completed NCT00680108 - A Study to Determine the Safety and Tolerability of Escalating Doses of INS365 Ophthalmic Solution Phase 2
Recruiting NCT06064071 - Clinical Study Evaluating Nordlys™ SWT IPL for Dry Eye Disease (DED) Due to MGD N/A
Completed NCT04139122 - Safety, PK and Efficacy Study of SJP-0132 in Subjects With Dry Eye Disease Phase 1/Phase 2
Not yet recruiting NCT06375343 - Study to Evaluating PRO-240 Ophthalmic Solution Compared to Optive® Phase 1
Completed NCT01468168 - A Study Assessing the Safety and Efficacy of DE-101 Ophthalmic Suspension in Dry Eye Patients Phase 2
Completed NCT01014078 - A Four Week Study of Azithromycin Ophthalmic Solution, 1% Versus Placebo in Subjects With Dry Eye Disease Phase 4
Completed NCT00799682 - Exploratory Study Comparing Signs and Symptoms in Patients With Ocular Hypertension or Glaucoma Using Xalatan R® or Travatan Z® Phase 4
Completed NCT05082974 - Investigator Initiated Study to Assess the Efficacy of OC-01 (Varenicline) Nasal Spray on Signs and Symptoms of Dry Eye Disease Following Laser-assisted in Situ Keratomileusis (LASIK) Phase 3
Recruiting NCT06146881 - Effectiveness of Diquafosol Prophylactic Therapy to Prevent Dry Eye Disease for Cataract Surgery Patients in Indonesia Phase 2
Completed NCT03292809 - CyclASol for the Treatment of Signs and Symptoms of Dry Eye Disease (DED) Phase 2/Phase 3