Clinical Trials Logo

Clinical Trial Summary

Background: Diabetic retinopathy (DR) is one of the most important causes of blindness worldwide, especially in developed countries. In diabetic patients, periodic examination of the back of the eye using a nonmydriatic camera has been widely demonstrated to be an effective system to control and prevent the onset of DR. Convolutional neural networks have been used to detect DR, achieving very high sensitivities and specificities. Hypothesis It is possible to develop algorithms based on artificial intelligence that can demonstrate equal or superior performance and that constitute an alternative to the current screening of RD and other ophthalmic pathologies in diabetic patients. Objectives: - Development of an artificial intelligence system for the detection of signs of retinal pathology and other ophthalmic pathologies in diabetic patients. - Scientific validation of the system to be used as a screening system in primary care. Methods: This project will consist of carrying out two studies simultaneously: 1. Development of an algorithm with artificial intelligence to detect signs of DR, other pathologies of the central retina and glaucoma in patients with diabetes. 2. Carrying out a prospective study that will make it possible to compare the diagnostic capacity of the algorithms with that of the family medicine specialists who read the background images. The reference will be double-blind reading by ophthalmologists who specialize in retina. Cession of the images began at the end of 2018. The development of the AI algorithm is calculated to last about 3 to 4 months. Inclusion of patients in the cohort will start in early 2019 and is expected to last 3 to 4 months. Preliminary results are expected to be published by the end of 2019. The study will allow the development of an algorithm based on AI that can demonstrate an equal or superior performance, and that constitutes a complement or an alternative, to the current screening of DR in diabetic patients


Clinical Trial Description

Study Design This project will follow a methodology consisting of 2 concomitant studies: In the first study, we will develop an AI algorithm to detect the signs of DR in patients with diabetes. The second part of the project will consist of the elaboration of a prospective study that will allow comparing the diagnostic capacity of the algorithm with that of the family medicine physicians and with retina specialists. The reference will be a blinded double reading conducted by the retina specialists (with a blinded third reading in case of disagreement in the previous 2 readings). In this way, the results obtained, both by the AI algorithm and by family medicine specialists, will be compared using the gold standard (accuracy, sensitivity, specificity, area under the curve, etc). The inclusion of nurses who received training in fundus readings will be considered to compare their diagnostic capacity. Study Population, Site Participation, and Recruitment Images for the development of the algorithm will be ceded by the CHS and will include images from the whole Catalan population. The prospective study will take place in the primary care centers managed by the Catalan Health Institute in Central Catalonia, which includes the counties of Bages, Osona, Berguedà, and Anoia. The reference population will be the population assigned to these primary care centers. This population included about 512,000 people in 2017, with an estimated prevalence of diabetes of 7.1%. The study period will include 2010-2017 for the development of the algorithm with AI. The prospective study will begin once the algorithm is developed and will run until the number of readings needed is obtained (about 3-4 months). Conduct of the Study For the development of the AI algorithm, all fundus images labeled as DR of patients from primary care centers in Catalonia between 2010 and 2017 will be included. For the prospective study, all the images of patients who underwent an eye fundus examination will be included from the study start period until the adequate number of patients is reached. A high percentage of fundus images must have sufficient quality; that is, a 40-degree vision of the central retina where at least a three-fourth part of the optic nerve, a well-focused macula, and well-defined veins and arteries of the upper and lower arcs can be seen. Eye fundus images that do not have adequate technical quality (dark) or that cannot be evaluated due to the opacity of the media (eg, for cataracts) will be excluded Data Collection For the development of the AI algorithm, it is necessary to have the anonymized images with the corresponding label that classifies each image (in one of the classes with which the algorithm is to be trained). The personnel responsible for information technology (IT) of the CHS will evaluate the best strategy for the anonymization and extraction of the images from the computer systems of the CHS, as well as the identification of each image with a unique identifier. On the other hand, a tabulated file type CSV or TXT will be required to relate each image identifier with the corresponding classification. The person responsible for IT of the CHS, together with the technical manager of OPTretina, will agree on the best way to transfer these 2 sources of information, in a secure way, from the CHS servers to the OPTretina servers (SSH File Transfer Protocol, external hard disk) depending on the volume of data to be transferred and the internal policy of the CHS. OPTretina is experienced in developing AI models for automatic fundus image classification and is a Spanish Agency of Medicines and Health Products-certified medical device manufacturer. For the prospective study, anonymized weekly fundus data readings collected by family medicine physician readers of fundus images in Central Catalonia will be collected. The images will be transferred to the OPTretina servers to be first analyzed by the diagnostic algorithm and then by the retina specialists who will make the definitive diagnosis. The person responsible for IT of the CHS, together with the technical manager of OPTretina, will agree on the best way to transfer these data in a secure manner. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04132401
Study type Interventional
Source Fundacio d'Investigacio en Atencio Primaria Jordi Gol i Gurina
Contact
Status Completed
Phase N/A
Start date May 1, 2021
Completion date September 26, 2023

See also
  Status Clinical Trial Phase
Completed NCT03660371 - ILM Peeling in PDR Patients Undergoing PPV for VH N/A
Completed NCT03660384 - Silicone Oil Versus Gas in PDR Patients Undergoing Vitrectomy N/A
Completed NCT03660345 - PPV With Internal Limiting Membrane Peeling for Treatment-Naïve DME Phase 3
Completed NCT04905459 - ARDA Software for the Detection of mtmDR
Active, not recruiting NCT04271709 - Manhattan Vision Screening and Follow-Up Study (NYC-SIGHT) N/A
Recruiting NCT03713268 - Intraoperative OCT Guidance of Intraocular Surgery II
Completed NCT05022615 - Comparing 3 Imaging Systems
Completed NCT00385333 - Metabolic Mapping to Measure Retinal Metabolism Phase 2
Recruiting NCT04101604 - Biomarkers of Common Eye Diseases
Completed NCT03702374 - Combined Antioxidant Therapy on Oxidative Stress, Mitochondrial Dysfunction Markers in Diabetic Retinopathy Phase 3
Completed NCT01908816 - An Open-label Extended Clinical Protocol of Ranibizumab to Evaluate Safety and Efficacy in Rare VEGF Driven Ocular Diseases. Phase 3
Completed NCT04009980 - Long-term Retinal Changes After Topical Citicoline Administration in Patients With Mild Signs of Diabetic Retinopathy in Type 1 Diabetes Mellitus. N/A
Completed NCT02924311 - Routine Clinical Practice for Use of Intravitreal Aflibercept Treatment in Patients With Diabetic Macular Edema
Not yet recruiting NCT06257082 - Video-based Patient Education Intervention for Diabetic Eye Screening in Latinx Communities N/A
Not yet recruiting NCT05452993 - Screening for Diabetic Retinopathy in Pharmacies With Artificial Intelligence Enhanced Retinophotography N/A
Withdrawn NCT02812030 - Aflibercept for Retinopathy in the Real World N/A
Completed NCT02391558 - Clinical Evaluation of Noninvasive OCT Angiography Using a Zeiss OCT Prototype to Compare to Fluorescein Angiography N/A
Active, not recruiting NCT02330042 - OCT Biomarkers for Diabetic Retinopathy
Active, not recruiting NCT02353923 - OcuStem Nutritional Supplement in Diabetic Patients With Mild to Moderate Non-proliferative Retinopathy N/A
Completed NCT02390245 - Philadelphia Telemedicine Glaucoma Detection and Follow-Up Study N/A