Dental Implant Failed Clinical Trial
Official title:
A Randomized Clinical Trial Comparing Autogenous Particles Harvesting During Implant Surgery Using Low-speed Drilling Without Irrigation and High-speed Drilling With Irrigation
The aim was to compare the osteoblast activity and osteogenic potential of autogenous bone particles harvested using three different techniques, determine the most advantageous method of collecting autogenous bone particles. Bone particles were harvested during dental implant surgery using low-speed drilling and high speed drilling. After the osteoblasts were cultured, cell proliferation, migration, mineralization, transcription of osteogenesis-related genes, secretion of osteogenesis-related proteins, and osteoinductive protein content in the bone particle matrix were evaluated
A total of 60 individual dental implants will be placed in this study. Each patient will receive two dental implants (Spain), each measuring 10 mm in length and 4 mm in diameter, for the replacement of missing teeth in the right and left mandibular first molars. The surgery will be performed under local anesthesia (0.5% articaine with epinephrine) with the elevation of a mucoperiosteal flap. For the randomization of the implant osteotomy milling protocol in each hemimandible, an online randomization service (www.randomization.com) will be utilized. In each patient, the conventional high-speed milling protocol with irrigation using physiological saline will be employed in one hemimandible. In the other hemimandible, the implant osteotomy will be performed using a low-speed milling protocol without irrigation. The milling sequence for the conventional high-speed milling protocol with irrigation will be as follows: the osteotomy will be initiated with a 2.0 mm diameter marking drill, followed by a pilot drill of the same diameter. Subsequently, drills of 2.6/3.2/ and 3.6 mm diameters will be used consecutively. All drills will be used at a speed of 800 rpm and at a depth of 10 mm. On the other hand, the milling sequence for the low-speed milling protocol without irrigation will be the same, but all drills will be used at a speed of 50 rpm (at the same depth of 10 mm). Finally, once the dental implant and closing screw are inserted, the mucoperiosteal flap will be sutured with simple stitches using synthetic polyamide suture, without immediate prosthetic loading. In all cases, postoperative medication will include 500 mg/8 h amoxicillin for 7 days (in cases of penicillin allergy, 300 mg/8 h clindamycin for 7 days), and 600 mg/8 h ibuprofen for 3 days. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT04370314 -
Retrospective Study on Clinical Performance of Screw-retained Implant Crowns
|
N/A | |
Completed |
NCT04620018 -
Comparison of Three Antibiotic Protocols in Prevention of Infection in Dental Implant Surgery
|
N/A | |
Recruiting |
NCT04073654 -
SA Versus SOI Surfaces for Single Implant-supported Crown
|
N/A | |
Completed |
NCT05739461 -
The Effect of Triangular Neck Design on Crestal Bone Loss
|
||
Not yet recruiting |
NCT05973357 -
The Influence of Vertical Implant Position With Immediate Provisionalization on the Marginal Bone Loss.
|
N/A | |
Completed |
NCT06099834 -
Evaluation of Osseointegration Process of Dental Implants
|
N/A | |
Active, not recruiting |
NCT06034067 -
Osseodensification Versus Conventional Drilling for Implant Site Preparation
|
N/A | |
Recruiting |
NCT04983758 -
20-year Implant Survival in Periodontally Healthy and Compromised Patients
|
||
Completed |
NCT03641365 -
Sleeves Versus Sleeveless Template
|
N/A | |
Completed |
NCT05724706 -
An Evaluation of Salivary Oxidant and Antioxidant Levels in Peri-implant Health and Disease
|
||
Completed |
NCT04270396 -
Early and Late Implant Failure
|
||
Recruiting |
NCT06123221 -
SINUS FLOOR WITH OSSEODENSIFICATION OR LATERAL WINDOW
|
N/A | |
Completed |
NCT05060055 -
Digital Assessment at Peri-implant Tissues After Immediate Implants With Customized Healing Abutments and Connective Tissue Grafts
|
N/A | |
Recruiting |
NCT04429373 -
Effect of Platelet-rich Plasm (PRF) on Two-implant Mandibular Overdenture: a Split Mouth
|
N/A | |
Not yet recruiting |
NCT03741036 -
Immediate Implant Placement With Provisionalization Using Different Bone Grafts as a Space Filling Material in the Maxillary Esthetic Zone
|
N/A | |
Completed |
NCT02625597 -
Assessment of the Effects of Different Implant Abutment Occluding Materials on Dental Implant Health Parameters and Microbiology
|
N/A | |
Completed |
NCT03720236 -
Peri-implant Tissues in BLX® Implants
|
N/A | |
Active, not recruiting |
NCT04518020 -
Single Crown Supported by Short Implant Versus Standard Implant in Conjunction With Maxillary Sinus Floor Augmentation.
|
N/A | |
Completed |
NCT06294171 -
Efficacy of Modified Piezosurgery Alveolar Bone Cut With Osseodensification Drills in Expanding Narrow Alveolar Bone
|
N/A | |
Withdrawn |
NCT03715439 -
Evaluation of Dental Implants Placed in Preserved and Non-preserved Post-extraction Ridges
|