Clinical Trials Logo

Clinical Trial Summary

To compare virtual planning accuracy of computer-assisted template-based implant placement using CAD/CAM stereolithographic surgical templates with or without metallic sleeves.Furthermore to compare open versus closed holes in case of sleeveless templates.

Any partially edentulous patients requiring at least one implant to be planed according to a computer-assisted template-based protocol were enrolled. Patients were randomised according to a parallel group design into two arms: surgical template with or without metallic sleeves. Three deviation parameters (angular, horizontal, vertical) were defined to evaluate the discrepancy between the planned and placed implant positions.


Clinical Trial Description

This study was designed as a randomized controlled trial of parallel group design conducted at one centre, between May 2016 and March 2017. The study was performed after approval was received from the institutional review board of the Aldent University, Tirana, Albania (2/2017).

The investigation was conducted according to the principles embodied in the Helsinki Declaration of 1975 for biomedical research involving human subjects, as revised in 2013. All patients were informed about the nature of the treatment and their written consent was obtained. Data collection was designed to preserve patient anonymity.

- Inclusion/exclusion criteria:

Any partially edentulous patient, aged 18 years or older, able to sign an informed consent, in need of an implant-supported fixed restoration was considered eligible for this study. Any potential implant location based on individual patient requirements was considered eligible in the present trial. Patients were not admitted to the study if any of the following exclusion criteria was present: general medical contraindication to oral surgery (American Society of Anesthesiologist, ASA, class III or IV); irradiation in the head and neck area less than one year before implantation; psychiatric problems; alcohol or drug abuse; pregnant or nursing; untreated periodontitis; severe bruxism or clenching; uncontrolled diabetes; poor oral hygiene and motivation; and inability to complete the follow-up.

Enrolled patients received preoperative photographs, periapical radiographs or panoramic x-rays for initial screening and evaluation. The prosthetic-driven planning workflow started by taking a cone beam computed tomography (CBCT) scan (Cranex 3Dx, Soredex, Tuusula, Finland) by using a wax bite to separate dental arches. Then, the patients received intraoral digital impression taken using the 3M True Definition Scanner (3M Italia, Pioltello, Milano). The digital data (STL, STereo Lithography interface format) was imported in a 3D design software (exocad DentalCAD, Exocad GmbH, Darmstadt, Germany) to realize a virtual wax-up according to the functional and esthetic requirements. Then, the STL and DICOM (Digital Imaging and COmmunications in Medicine) data were imported in a 3D software planning program (3Diagnosys ver. 5.0, 3DIEMME srl, Cantù, Italy). Then, the reprocessed surface extrapolated from the DICOM data (by using a Hounsfield scale filter) and the surface generated by the master cast scanning process, or by the intraoral scanning process, were merged with the best-fitting repositioning tools of the software (3Diagnosys ver. 5.0, 3DIEMME srl). At this point, prosthetic-driven implants/abutments size and location were planned taking into account the bone quality and quantity, soft tissue thickness, anatomical landmarks, as well as, type, volume and shape of the final restoration. After careful functional and esthetic evaluation and final verification, the prosthetic-driven plan was approved. At this point, patients were randomly assigned to receive conventional stereolithographic surgical template with (control group) or without (test group) metallic sleeves. Stereolithographic surgical templates were designed and fabricated by an independent certified center not previously involved in the study (New Ancorvis srl, Bargellino, Italy). In the test group, conventional templates with close-sleeve-design were produced to place implants between premolars. In case of implants to be place in molar area, template with open sites were produced to solve intermaxillary space limits.

- Surgical protocol:

One hour before implant placement, all patients underwent professional oral hygiene, prophylactic antiseptic with 0.2% chlorhexidine (Curasept, Curaden Healthcare, Saronno, Italy) for one minute, and prophylactic antibiotic therapy (2 g of amoxicillin or clindamycin 600 mg if allergic to penicillin). The fit of the surgical templates were accurately tried in the patient mouth to achieve a stable fit (Fit Checker, GC - Tokyo, Japan). All patients were treated under local anesthesia using articaine with adrenaline 1:100000 administered 20 minute before surgery. The surgical templates were stabilized on the residual teeth and fixed with two to three preplanned anchor pins.Hopeless teeth were extracted at the end of the intervention in order to improve the stability of the surgical template and to provide more reference point for measurements of the implant accuracy. Nevertheless, in case of immediate postextractive implants, residual teeth were extracted as atraumatically as possible immediately before surgery. In the test group, planned implants (Osstem TSIII, Osstem, Seoul, South Korea) were placed flapless using dedicate drills (OneGuide Kit, Osstem) in combination with a sleeveless surgical guide. In this case the drills were used directly thought the sleeve-designed template without metallic tubs and with not the need of drill reductions. In the control group, planned implants (Osstem TSIII, Osstem, Seoul, South Korea) were placed flapless using dedicate drills (OsstemGuide Kit[Taper], Osstem) in combination with reduction tools, within the surgical templates containing metallic sleeves. If the keratinized gingiva and the amount of bone were adequate, the implants were placed flapless. Otherwise, a flap was elevated and then the wound was closed with single-stitch sutures using 4.0 resorbable suture material (Vicryl, Ethicon J&J International, Sint-Stevens-Woluwe, Belgium). Implant site were prepared based on the bone density evaluated by the surgeon at the first drill. All the implant were inserted according to a one-stage protocol, with an insertion torque ranging from 35 to 45 Ncm. In case of poor bone density, the implant site was underprepared. Immediately after implant placement, patients of both groups receive a digital impression (3M True Definition Scanner, 3M Italia, Pioltello, Milano) taken at implant level using a dedicate abutments (Scan body type AQ, New Ancorvis srl), to check the position of the placed implants.

Following implant placement, all patients received oral and written recommendations about medication, oral hygiene maintenance and diet. Implants were loaded after 8 to 12 weeks of healing. Then, patients were followed twice a year for hygiene maintenance and occlusal control.

- Outcome measurements:

- Implant failure: an implant was considered to be a failure if it was lost for mobility, implant fracture and/or any infection dictating implant removal. The stability of each individual implant was measured manually with a torque of 20 Ncm at delivery of the final restoration and later, with the prosthesis removed, if needed (infection, extensive peri-apical bone loss, mucosal inflammation).

- Template-related complications: early surgical complications involved the surgical template comprised limited access in posterior areas, buccal bony dehiscence (due to a mismatching of the surgical template) evaluated sounding the implant site with a periodontal probe (PCPUNC156, Hu-Friedy Italy, Milan, Italy) before implant placement, insertion of different implant than planned, and fracture of surgical template. All the complications were recorded during follow-up by the same clinician (Marco Tallarico), who performed all the surgical procedures.

- Accuracy: Three deviation parameters (horizontal, vertical, and angular) were defined and calculated between the planned and placed implant positions. The post-operative STL file, derived from the intraoral scan, was geometrically aligned with the files exported from the planning, by automated image registration using maximization of mutual information (Dental SCAN, ver.6, Open Technologies srl, Brescia, Italy). The horizontal (lateral), vertical (depth) and angular deviation between virtual and placed implants were calculated along the long axis of each implants. An expert blinded mechanical engineer (FC) performed all the measurements.

- Randomization:

One computer-generated restricted randomization list was created. Only one of the investigators, not involved in the selection and treatment of the patients, was aware of the random sequence and could have access to the randomization lists stored in a password-protected portable computer. The random codes were enclosed in sequentially numbered, identical, opaque, sealed envelopes. Envelopes were opened sequentially after the prosthetic-driven plan was approved.

- Statistical analysis:

Patient data were collected in a Numbers spreadsheet (Version 3.6.1 for Mac OS X 10.11.4). A bio-statistician with expertise in dentistry analyzed the data using SPSS software for Mac OS X (version 22.0; SPSS Inc., Chicago, IL, USA) for statistical analysis. Descriptive analysis was performed for numeric parameters using mean±standard deviation and median with confidence interval (95% CI). Implant failure and template-related complications between the two groups were compared using Fisher's exact probability test. The mean differences of the overall deviation in the clinical outcomes compared to the virtual plan, were compared between groups using a mixed-model repeated-measures analysis of variance (ANOVA). In the sleeve-less group, accuracy of open versus closed holes were also evaluated. All statistical comparisons were conducted with a P value set at 0.05. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT03641365
Study type Interventional
Source Osstem AIC
Contact
Status Completed
Phase N/A
Start date September 1, 2017
Completion date May 30, 2018

See also
  Status Clinical Trial Phase
Recruiting NCT02228473 - Effect of Glycopyrrolate and Atropine on Catheter-Related Bladder Discomfort N/A
Recruiting NCT02246153 - Laparoscopy-assisted and Open Distal Gastrectomy for Gastric Cancer in the Elderly Patients Phase 3
Recruiting NCT01917253 - Standard Length Catheters vs Long Catheters in Peripheral Vein Cannulation. N/A
Completed NCT02245854 - Efficacy and Safety of a New Polypectomy Snare for Cold-polypectomy for Small Colorectal Polyps N/A
Completed NCT01574196 - Assessment of Cardiac Autonomic Function in Adulthood After Chemotherapy or Radiotherapy in Childhood N/A
Completed NCT02447523 - The Impact of Metabolic Syndrome on Patients Undergoing Elective Laparotomy N/A
Terminated NCT00616824 - The Use of an Acellular Dermal Matrix in a Two-Staged Breast Reconstruction Phase 4
Completed NCT04061655 - Effect of Intravenous Iron Supplementation in Reducing Allogenic Blood Transfusion Early Phase 1
Completed NCT02901665 - Impact of Increased Parent Presence in the Neonatal Intensive Care Unit on Parent & Infant Outcomes N/A
Completed NCT02675166 - Getting Long-term Management of Adult Children Cured of Childhood Cancer in Rhône-Alpes
Completed NCT01997658 - Preoperative Glucocorticoid Use in Major Hepatectomy Phase 2/Phase 3
Not yet recruiting NCT02252445 - Propofol and Sevoflurane for Catheter-Related Bladder Discomfort N/A
Active, not recruiting NCT01775150 - Saving Mother and Baby With Text Messaging N/A
Completed NCT01631799 - Outcome of Patients After Total Knee Replacement: A Comparison of Femoral Nerve Block and Epidural Anesthesia N/A
Completed NCT03440138 - Defining Benchmarks in Bariatric Surgery
Recruiting NCT02835404 - Pelvic External Combined With 252-Cf Neutron Intracavitary Radiotherapy With or Without Platinum in Treating Advanced Cervical Cancer Phase 2
Completed NCT01489800 - The Impact of Early Feeding After Radical Cystectomy for Bladder Cancer N/A
Completed NCT02096224 - Sevoflurane Versus Desflurane for Catheter-related Bladder Discomfort N/A
Completed NCT01531478 - Long-term Follow-up of Childhood Cancer Survivors in the Rhône-Alpes and Auvergne Regions of France N/A
Withdrawn NCT00905229 - Comparing Different Routes and Doses of Phytonadione (Vitamin K) for Reversing Warfarin Treated Patients With Hip Fracture Before Surgery N/A