Myocardial Ischemia Clinical Trial
Official title:
Magnetocardiography as a Noninvasive Diagnostic Strategy for Suspected Myocardial Ischemia With No Obstructive Coronary Artery Disease
A prospective, multicenter, observational, single-arm trial to validate CardioFlux MCG's ability to diagnose myocardial ischemia caused by coronary microvascular dysfunction in patients with suspected ischemia and confirmed no obstructive coronary artery disease (suspected INOCA) by using diagnostic measures of coronary flow reserve (CFR) via invasive angiography as a reference standard for diagnosis.
Magnetocardiography (MCG) is a noninvasive imaging modality that has been extensively studied over the past several decades as a diagnostic imaging solution for various forms of cardiovascular disease. MCG measures the magnetic field that arises from the electrical activity of the heart's pacemaker activity, the very same activity which yields surface electric field potentials as measured by the electrocardiogram. Unlike electrocardiographic signals, however, MCG signals are undistorted by conductive tissue noise, and are highly sensitive to ischemic injury and vortex currents missed by the same electrocardiographic measurements. Accordingly, numerous clinical trials suggest the usefulness of MCG for the evaluation of ischemia in patients with suspected acute coronary syndrome. There is a growing body of evidence demonstrating the usefulness of MCG in the detection of myocardial ischemia, both in patients with symptoms of ACS, and in patients with stable angina. Since MCG is a functional assessor of depolarization and repolarization heterogeneity, it is hypothesized that MCG may be a useful frontline diagnostic modality to identify CMD in patients who would otherwise have normal coronary CT angiograms and/or stress tests. The proposed study intends to study the diagnostic accuracy of MCG in patients with suspected INOCA. This demonstrates a significant unmet clinical need in the assessment of patients, and especially women, with INOCA. The current standard of care for these patients is resource/time intensive and associated with a significant rate of non-diagnostic clinical data requiring expensive and invasive evaluation for safe patient management. Magnetocardiography offers the potential for rapid, safe, noninvasive, non-radiologic assessment of the INOCA population, and may lead to earlier treatment strategies for CMD patients. From the participating clinical sites, patients age ≥18 years who presented with chest pain or exertional dyspnea concerning for myocardial ischemia with no obstructive epicardial CAD on invasive or computed tomographic coronary angiography will be screened and subsequently enrolled when meeting criteria. This is a prospective observational study used for clinical data collection for the clinical validation testing of the CardioFlux MCG system. There will be no intervention introduced by the study device. The interpretation of the CardioFlux MCG data made by the study reader(s) will not be known to the patient's treating physician. Similarly, the patient's coronary physiology data, diagnosis, or interventions made by the patient's treating physician in following the standard of care will not be known to any of the scan readers. Except for the introduction of the MCG scan, there will be no other alteration to the patient standard of care. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Not yet recruiting |
NCT06032572 -
Evaluation of the Safety and Effectiveness of the VRS100 System in PCI (ESSENCE)
|
N/A | |
Recruiting |
NCT05846893 -
Drug-Coated Balloon vs. Drug-Eluting Stent for Clinical Outcomes in Patients With Large Coronary Artery Disease
|
N/A | |
Completed |
NCT04153006 -
Comparison of Fingerstick Versus Venous Sample for Troponin I.
|
||
Completed |
NCT01205776 -
EXCEL Clinical Trial
|
N/A | |
Active, not recruiting |
NCT04555174 -
BIOFLOW-VIII All-comers Orsiro Mission Safety and Performance Registry
|
||
Recruiting |
NCT04582877 -
Pressure Guidewire System Multi-center, Prospective, Self-Control, Clinical Trial
|
N/A | |
Recruiting |
NCT04390672 -
Multivessel TALENT
|
N/A | |
Recruiting |
NCT03265535 -
Validation of a Single Rest-Stress Imaging Protocol for Myocardial Perfusion Imaging
|
||
Not yet recruiting |
NCT04522583 -
Increased CRP Concentrations in Patients Admitted to the Emergency Department With Troponin Elevation Aids to Rule Out Coronary Ischemia
|
||
Completed |
NCT02554006 -
Predischarge Bundle to Minimize Negative Impact on Quality of Life of Nuisance Bleedings
|
N/A | |
Terminated |
NCT02407626 -
Optimization of Cardioprotection in Diabetic Patients Undergoing Cardiac Surgery
|
N/A | |
Completed |
NCT02510547 -
Comparison of a CrossBoss First Versus Standard Wire Escalation Strategy for Crossing Coronary Chronic Total Occlusion: the "CrossBoss First" Trial
|
Phase 4 | |
Active, not recruiting |
NCT02189499 -
Feasibility Study of the Amaranth Medical FORTITUDE Bioresorbable Drug-Eluting Coronary Stent
|
Phase 2 | |
Completed |
NCT02197065 -
Pilot Study of Atorvastatin for Orthopedic Surgery Patients
|
Phase 2 | |
Completed |
NCT02264717 -
Dan-NICAD - Danish Study of Non-Invasive Diagnostic Testing in Coronary Artery Disease
|
N/A | |
Recruiting |
NCT01681381 -
Evaluate Safety And Effectiveness Of The Tivoli® DES and The Firebird2® DES For Treatment Coronary Revascularization
|
N/A | |
Completed |
NCT01679886 -
Comparison of Rubidium PET and SPECT With CZT Crystals for Detection of Myocardial Ischemia in Overweighed Patients and Women
|
N/A | |
Completed |
NCT01655043 -
Absolute Quantification of Coronary Flow Reserve by Stress Perfusion MRI
|
Phase 2 | |
Terminated |
NCT01892917 -
BIOFLOW-III Hungary Satellite Registry
|
N/A | |
Completed |
NCT02707445 -
Genotyping Influences Outcome of Coronary Artery Stenting
|
N/A |