Clinical Trials Logo

Coronary Artery Stenosis clinical trials

View clinical trials related to Coronary Artery Stenosis.

Filter by:

NCT ID: NCT00349895 Completed - Clinical trials for Coronary Artery Disease

Healthy Endothelial Accelerated Lining Inhibits Neointimal Growth

Start date: August 2006
Phase: Phase 4
Study type: Interventional

This is a multi-center, prospective, non-randomized study. Approximately 90 patients from up to 16 centers will be entered in the study. Patients will be followed clinically for up to 5 years post-procedure. All patients will have a repeat angiography at 6 months follow-up. The primary objective of this study is to evaluate the safety and effectiveness of the Genous Bio-engineered R stentTM in conjunction with optimal statin therapy (80mg of atorvastatin), in the treatment of elective patients with up to two de novo native coronary artery lesions. The Genous stent received CE mark for the intended indication in August 2005

NCT ID: NCT00180479 Completed - Clinical trials for Coronary Artery Disease

SPIRIT III Clinical Trial of the XIENCE V® Everolimus Eluting Coronary Stent System (EECSS)

Start date: June 2005
Phase: Phase 3
Study type: Interventional

This study is divided into 5 arms: 1. Randomized Clinical Trial (RCT): Prospective, randomized, active-controlled, single blind, parallel two-arm multi-center clinical trial in the United States (US) comparing XIENCE V® Everolimus Eluting Coronary Stent System (CSS) (2.5, 3.0, 3.5 mm diameter stents) to the Food and Drug Administration (FDA) approved commercially available active control TAXUS® EXPRESS2™ Paclitaxel Eluting Coronary Stent (TAXUS® EXPRESS2™ PECS) System 2. US 2.25 mm non-randomized arm using 2.25 mm diameter XIENCE V® Everolimus Eluting CSS 3. US 4.0 mm non-randomized arm using 4.0 mm diameter XIENCE V® Everolimus Eluting CSS 4. US 38 mm non-randomized arm using 38 mm in length XIENCE V® Everolimus Eluting CSS 5. Japanese non-randomized arm using XIENCE V® Everolimus Eluting CSS (2.5, 3.0, 3.5, 4.0 mm diameter stents) in Japan The TAXUS® EXPRESS2™ Paclitaxel Eluting Coronary Stent System is Manufactured by Boston Scientific.

NCT ID: NCT00180453 Completed - Clinical trials for Coronary Artery Disease

SPIRIT FIRST Clinical Trial of the Abbott Vascular XIENCE V® Everolimus Eluting Coronary Stent System

Start date: December 2003
Phase: Phase 3
Study type: Interventional

Prospective, randomized, controlled, single-blinded, parallel two-arm, multicenter trial. Test arm: XIENCE V® Everolimus Eluting Coronary Stent System(stent length: 18mm, diameter: 3.0mm) Control arm: Metallic stent (MULTI-LINK VISION® metallic stent(stent length: 18mm, diameter: 3.0mm) Follow-up angiographic imaging and intra vascular ultra sound (IVUS) at 180 days and 1 year