Cornea Clinical Trial
Official title:
Repeatability and Reproducibility of the IOLMaster 700 Vers 1.70 and Agreement With IOLMaster 700 Vers. 1.50 and Pentacam
Verified date | May 2018 |
Source | Carl Zeiss Meditec, Inc. |
Contact | n/a |
Is FDA regulated | No |
Health authority | |
Study type | Observational |
The objectives of this study are to determine the agreement of measurements between the
IOLMaster 700 SW Vers. 1.70 and IOLMaster 700 SW Vers. 1.50 and Pentacam, as well as to
evaluate the repeatability and reproducibility of the IOLMaster 700 SW Vers 1.70.
The following parameters will be evaluated for Total Keratometry, (TK) and Posterior Corneal
Surface (PCS):
- cylinder (CYL), Axis (A)
- spherical equivalent (SE)
Specific Objectives:
1. To compare the agreement of SE between IOLMaster 700 SW Vers. 1.70 and IOLMaster 700 SW
Vers. 1.50 (Carl Zeiss Meditec AG, Jena, Germany)
2. To compare the agreement of Cylinder magnitude and axis between IOLMaster 700 SW Version
1.70 and Pentacam
3. To evaluate the repeatability and reproducibility of the IOLMaster 700 SW Vers. 1.70 for
all measurement parameters listed above
Status | Completed |
Enrollment | 98 |
Est. completion date | April 20, 2018 |
Est. primary completion date | April 20, 2018 |
Accepts healthy volunteers | Accepts Healthy Volunteers |
Gender | All |
Age group | 22 Years and older |
Eligibility |
Inclusion Criteria: 1. Male or Female 22 years of age and older. 2. No history of rigid contact lens wear for at least 2 weeks. Soft lenses, if worn, should be removed at least one hour prior to the measurement. 3. Able and willing to make the required study visits. 4. Able and willing to give consent and follow study instructions. 5. Group 1: normal eyes with best-corrected visual acuity of 20/20 or better, and lens opacities of 1.0 or less in the study eye using the LOCS III system, and no prior Laser Vision Correction. 6. Group 2: cataract in the study eye greater than Grade 1 using the LOCS III system for one or more: nuclear opacity, nuclear color, cortical opacity, or PSC. 7. Group 3: history of Laser Vision Correction (LVC). Exclusion Criteria: 1. Previous intraocular surgery other than Laser Vision Correction in the study eye. 2. Previous corneal surgery other than Laser Vision Correction in the study eye. 3. Presence of any corneal or retinal abnormality on slit lamp examination in the study eye. 4. Corneal Cylinder < 0.75D measured with a IOLMaster. 5. Active ocular infection or inflammation. 6. Poor tear film/insufficient corneal reflex. 7. Best corrected visual acuity worse than 20/200 in the study eye. 8. Physical inability to be positioned at the slit-lamp biomicroscope or study devices (e.g. torticollis, head tremor, etc.). 9. Insufficient eyelid opening or eyelashes which partially conceal alignment or keratometry reflections and prevent capture of all measurements. 10. Inability to fixate (e.g. due to nystagmus, amblyopia or ocular disease, such as macular degeneration). 11. Rigid contact lens wear during past two weeks. 12. Principal Investigator's determination that the subject is not suitable due to other medical condition (reasons to be listed on eCRFs). |
Country | Name | City | State |
---|---|---|---|
United States | Slade & Baker Vision | Houston | Texas |
Lead Sponsor | Collaborator |
---|---|
Carl Zeiss Meditec, Inc. | ClinReg Consulting Services, Inc., Sierra Clinical Services, LLC |
United States,
Baumeister M, Terzi E, Ekici Y, Kohnen T. Comparison of manual and automated methods to determine horizontal corneal diameter. J Cataract Refract Surg. 2004 Feb;30(2):374-80. — View Citation
Lu MJ, Zhong WH, Liu YX, Miao HZ, Li YC, Ji MH. Sample Size for Assessing Agreement between Two Methods of Measurement by Bland-Altman Method. Int J Biostat. 2016 Nov 1;12(2). pii: /j/ijb.2016.12.issue-2/ijb-2015-0039/ijb-2015-0039.xml. doi: 10.1515/ijb-2015-0039. — View Citation
Vogel A, Dick HB, Krummenauer F. Reproducibility of optical biometry using partial coherence interferometry : intraobserver and interobserver reliability. J Cataract Refract Surg. 2001 Dec;27(12):1961-8. — View Citation
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | Measurement Agreement between IOL Master Software Versions 1.70 and 1.50. | IOLMaster 700 Vers. 1.70 SE_TK (Spherical Equivalent_Total Keratometry) Measurements will be compared to IOLMaster 700 SW Vers. 1.50 SE_K (Spherical Equivalent_Keratometry) Measurements for Agreement. | 1 hour | |
Primary | Measurement Agreement between IOLMaster Software Version 1.70 and Pentacam. | IOLMaster 700 Vers. 1.70 A_TK (Axis_Total Keratometry), Cyl_TK (Cylinder_Total Keratometry), A_PCS (Axis_Posterior Corneal Surface), SE_PCS (Spherical Equivalent_Posterior Corneal Surface), and Cyl_PCS (Cylinder_Posterior Corneal Surface) Measurements will be compared to Pentacam Measurements for Agreement. | 1 hour | |
Primary | Repeatability and Reproducibility of IOLMaster 700 Software Version 700 Measurements. | 3. Evaluate the Repeatability and Reproducibility of the IOLMaster 700 SW Version 1.70 for A_TK, A_PCS, Cyl_TK, Cyl_PCS, SE_TK and SE_PCS. | 1 hour |
Status | Clinical Trial | Phase | |
---|---|---|---|
Terminated |
NCT03674892 -
Intranasal Neurostimulation in Ameliorating Symptoms of Neuropathic Corneal Pain
|
N/A | |
Recruiting |
NCT04439552 -
fMRI and IVCM Cornea Microscopy of CXL in Keratoconus
|
||
Not yet recruiting |
NCT04122651 -
Toric Intraocular Lenses for Cataract Patients in the NHS
|
N/A | |
Recruiting |
NCT03299530 -
Accuracy of Corneal Astigmatism in Different Region Modes
|
||
Completed |
NCT04560790 -
Safety and Efficacy of CRISPR/Cas9 mRNA Instantaneous Gene Editing Therapy to Treat Refractory Viral Keratitis
|
N/A | |
Recruiting |
NCT03010748 -
Multi-center Clinical Trial on Corneal Morphology Analysis in Chinese Population
|
||
Completed |
NCT02293122 -
To Investigate Agreement Between the EM-3000 and the Predicate Device Noncon Robo Pachy (F&A) (CellChek XL)
|
||
Active, not recruiting |
NCT06389916 -
Euclid Phoenix Lens Design Trial
|
N/A | |
Completed |
NCT06353776 -
MicroPulse Transscleral Laser Therapy and Its Short-term Impact on Ocular Surface
|
N/A | |
Completed |
NCT03906513 -
Evaluation of the Efficacy of OMK2 in Recovering Corneal Neural Damage in Patients With Diabetes
|
N/A | |
Not yet recruiting |
NCT06392607 -
Euclid Phoenix Lens Design Trial 2
|
N/A | |
Recruiting |
NCT05232539 -
Efficiency of Intraoperative Optical Coherence Tomography (iOCT)
|
N/A | |
Completed |
NCT02781948 -
Evaluation of the Repeatability and Reproducibility of Corneal Epithelial Thickness Mapping With iVue SD-OCT
|
N/A | |
Not yet recruiting |
NCT05345652 -
Evaluation Of Deep Anterior Lamellar Keratoplasty By Anterior Segment Ocular Coherence Tomography
|
||
Completed |
NCT04804592 -
Investigation in Corneal Sensation and Contact Lens Wear
|
N/A | |
Recruiting |
NCT04626583 -
Safety of Locally Delivered Allogeneic Mesenchymal Stromal Cells
|
Phase 1 | |
Recruiting |
NCT04323358 -
Agreement and Accuracy of Different Devices for Biometry Measurements in Patients With Cataract
|
N/A | |
Completed |
NCT06277349 -
Multifocal-toric IOL Compared to Multifocal IOL Combined With Limbal Relaxing Incisions for Correction of Moderate Astigmatism During Cataract Surgery
|
N/A | |
Withdrawn |
NCT02395952 -
Healing of Persistent Epithelial Defects
|
N/A | |
Terminated |
NCT04969406 -
A Prospective Trial of the Intelon BOSS(TM) System
|
N/A |