Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT03518775
Other study ID # IOLMaster 2017-01909
Secondary ID
Status Completed
Phase
First received
Last updated
Start date March 16, 2018
Est. completion date April 20, 2018

Study information

Verified date May 2018
Source Carl Zeiss Meditec, Inc.
Contact n/a
Is FDA regulated No
Health authority
Study type Observational

Clinical Trial Summary

The objectives of this study are to determine the agreement of measurements between the IOLMaster 700 SW Vers. 1.70 and IOLMaster 700 SW Vers. 1.50 and Pentacam, as well as to evaluate the repeatability and reproducibility of the IOLMaster 700 SW Vers 1.70.

The following parameters will be evaluated for Total Keratometry, (TK) and Posterior Corneal Surface (PCS):

- cylinder (CYL), Axis (A)

- spherical equivalent (SE)

Specific Objectives:

1. To compare the agreement of SE between IOLMaster 700 SW Vers. 1.70 and IOLMaster 700 SW Vers. 1.50 (Carl Zeiss Meditec AG, Jena, Germany)

2. To compare the agreement of Cylinder magnitude and axis between IOLMaster 700 SW Version 1.70 and Pentacam

3. To evaluate the repeatability and reproducibility of the IOLMaster 700 SW Vers. 1.70 for all measurement parameters listed above


Recruitment information / eligibility

Status Completed
Enrollment 98
Est. completion date April 20, 2018
Est. primary completion date April 20, 2018
Accepts healthy volunteers Accepts Healthy Volunteers
Gender All
Age group 22 Years and older
Eligibility Inclusion Criteria:

1. Male or Female 22 years of age and older.

2. No history of rigid contact lens wear for at least 2 weeks. Soft lenses, if worn, should be removed at least one hour prior to the measurement.

3. Able and willing to make the required study visits.

4. Able and willing to give consent and follow study instructions.

5. Group 1: normal eyes with best-corrected visual acuity of 20/20 or better, and lens opacities of 1.0 or less in the study eye using the LOCS III system, and no prior Laser Vision Correction.

6. Group 2: cataract in the study eye greater than Grade 1 using the LOCS III system for one or more: nuclear opacity, nuclear color, cortical opacity, or PSC.

7. Group 3: history of Laser Vision Correction (LVC).

Exclusion Criteria:

1. Previous intraocular surgery other than Laser Vision Correction in the study eye.

2. Previous corneal surgery other than Laser Vision Correction in the study eye.

3. Presence of any corneal or retinal abnormality on slit lamp examination in the study eye.

4. Corneal Cylinder < 0.75D measured with a IOLMaster.

5. Active ocular infection or inflammation.

6. Poor tear film/insufficient corneal reflex.

7. Best corrected visual acuity worse than 20/200 in the study eye.

8. Physical inability to be positioned at the slit-lamp biomicroscope or study devices (e.g. torticollis, head tremor, etc.).

9. Insufficient eyelid opening or eyelashes which partially conceal alignment or keratometry reflections and prevent capture of all measurements.

10. Inability to fixate (e.g. due to nystagmus, amblyopia or ocular disease, such as macular degeneration).

11. Rigid contact lens wear during past two weeks.

12. Principal Investigator's determination that the subject is not suitable due to other medical condition (reasons to be listed on eCRFs).

Study Design


Related Conditions & MeSH terms


Intervention

Device:
Biometry
Measurement of Cornea

Locations

Country Name City State
United States Slade & Baker Vision Houston Texas

Sponsors (3)

Lead Sponsor Collaborator
Carl Zeiss Meditec, Inc. ClinReg Consulting Services, Inc., Sierra Clinical Services, LLC

Country where clinical trial is conducted

United States, 

References & Publications (3)

Baumeister M, Terzi E, Ekici Y, Kohnen T. Comparison of manual and automated methods to determine horizontal corneal diameter. J Cataract Refract Surg. 2004 Feb;30(2):374-80. — View Citation

Lu MJ, Zhong WH, Liu YX, Miao HZ, Li YC, Ji MH. Sample Size for Assessing Agreement between Two Methods of Measurement by Bland-Altman Method. Int J Biostat. 2016 Nov 1;12(2). pii: /j/ijb.2016.12.issue-2/ijb-2015-0039/ijb-2015-0039.xml. doi: 10.1515/ijb-2015-0039. — View Citation

Vogel A, Dick HB, Krummenauer F. Reproducibility of optical biometry using partial coherence interferometry : intraobserver and interobserver reliability. J Cataract Refract Surg. 2001 Dec;27(12):1961-8. — View Citation

Outcome

Type Measure Description Time frame Safety issue
Primary Measurement Agreement between IOL Master Software Versions 1.70 and 1.50. IOLMaster 700 Vers. 1.70 SE_TK (Spherical Equivalent_Total Keratometry) Measurements will be compared to IOLMaster 700 SW Vers. 1.50 SE_K (Spherical Equivalent_Keratometry) Measurements for Agreement. 1 hour
Primary Measurement Agreement between IOLMaster Software Version 1.70 and Pentacam. IOLMaster 700 Vers. 1.70 A_TK (Axis_Total Keratometry), Cyl_TK (Cylinder_Total Keratometry), A_PCS (Axis_Posterior Corneal Surface), SE_PCS (Spherical Equivalent_Posterior Corneal Surface), and Cyl_PCS (Cylinder_Posterior Corneal Surface) Measurements will be compared to Pentacam Measurements for Agreement. 1 hour
Primary Repeatability and Reproducibility of IOLMaster 700 Software Version 700 Measurements. 3. Evaluate the Repeatability and Reproducibility of the IOLMaster 700 SW Version 1.70 for A_TK, A_PCS, Cyl_TK, Cyl_PCS, SE_TK and SE_PCS. 1 hour
See also
  Status Clinical Trial Phase
Terminated NCT03674892 - Intranasal Neurostimulation in Ameliorating Symptoms of Neuropathic Corneal Pain N/A
Recruiting NCT04439552 - fMRI and IVCM Cornea Microscopy of CXL in Keratoconus
Not yet recruiting NCT04122651 - Toric Intraocular Lenses for Cataract Patients in the NHS N/A
Recruiting NCT03299530 - Accuracy of Corneal Astigmatism in Different Region Modes
Completed NCT04560790 - Safety and Efficacy of CRISPR/Cas9 mRNA Instantaneous Gene Editing Therapy to Treat Refractory Viral Keratitis N/A
Recruiting NCT03010748 - Multi-center Clinical Trial on Corneal Morphology Analysis in Chinese Population
Completed NCT02293122 - To Investigate Agreement Between the EM-3000 and the Predicate Device Noncon Robo Pachy (F&A) (CellChek XL)
Active, not recruiting NCT06389916 - Euclid Phoenix Lens Design Trial N/A
Completed NCT06353776 - MicroPulse Transscleral Laser Therapy and Its Short-term Impact on Ocular Surface N/A
Completed NCT03906513 - Evaluation of the Efficacy of OMK2 in Recovering Corneal Neural Damage in Patients With Diabetes N/A
Not yet recruiting NCT06392607 - Euclid Phoenix Lens Design Trial 2 N/A
Recruiting NCT05232539 - Efficiency of Intraoperative Optical Coherence Tomography (iOCT) N/A
Completed NCT02781948 - Evaluation of the Repeatability and Reproducibility of Corneal Epithelial Thickness Mapping With iVue SD-OCT N/A
Not yet recruiting NCT05345652 - Evaluation Of Deep Anterior Lamellar Keratoplasty By Anterior Segment Ocular Coherence Tomography
Completed NCT04804592 - Investigation in Corneal Sensation and Contact Lens Wear N/A
Recruiting NCT04626583 - Safety of Locally Delivered Allogeneic Mesenchymal Stromal Cells Phase 1
Recruiting NCT04323358 - Agreement and Accuracy of Different Devices for Biometry Measurements in Patients With Cataract N/A
Completed NCT06277349 - Multifocal-toric IOL Compared to Multifocal IOL Combined With Limbal Relaxing Incisions for Correction of Moderate Astigmatism During Cataract Surgery N/A
Withdrawn NCT02395952 - Healing of Persistent Epithelial Defects N/A
Terminated NCT04969406 - A Prospective Trial of the Intelon BOSS(TM) System N/A