View clinical trials related to Constriction, Pathologic.
Filter by:The objective of this pivotal study is to evaluate the safety and efficacy of the CGuard™ Carotid Stent System in the treatment of carotid artery stenosis in symptomatic and asymptomatic patients undergoing carotid artery stenting (CAS) to a performance goal developed from published CAS literature.
The purpose of this study is to determine the prevalence of transthyretin cardiac amyloidosis (TTR-CA) among patients with moderate and severe aortic stenosis in Southeast Minnesota using 99mTc-PYP single-photon positive emission computed tomography with computed tomography (SPECT/CT).
To Evaluate the Safety and Effectiveness of Transcatheter Aortic Valve System ( Chengdu Silara Medtech Inc. ,Chengdu, China)in Patients with Severe Aortic Stenosis with or without Moderate or Lower Degree Regurgitation
This study objective is to establish the safety and effectiveness of the Edwards SAPIEN 3 / SAPIEN 3 Ultra / SAPIEN 3 Ultra RESILIA Transcatheter Heart Valve systems in subjects with moderate, calcific aortic stenosis. Following completion of enrollment, subjects will be eligible for enrollment in the continued access phase of the trial.
Aortic valve stenosis (AS) affects 2-7% of persons > 65 years, symptoms include: angina and dyspnea, dizziness and syncope. Coincidence of coronary artery disease (CAD), also presenting with angina and dyspnea, in patients with AS between 40 - 65% . Angina in AS caused by significant reduction of coronary flow reserve (CFR). CFR is the ratio of maximal flow increase in the coronary vessel bed during maximal hyperaemia (medically or exercise induced). FFR (fractional flow reserve) use in patients with AS potentially invalid due to dysfunctional CFR leading to potential undertreatment of CAD in these patients.CFR disturbance in AS mainly due to myocardial overload causing concentric hypertrophy, increased oxygen consumption and neurohormonal activation leading to increased vascular resistance. Current studies are investigating the validity of FFR and iFR in AS patients. Recent data demonstrate very good correlation between FFR and iFR derived values to PET myocardial perfusion imaging values in patients with no evidence of AS. Our study aims to investigate the diagnostic performance of FFR and iFR in intermediate-grade coronary stenosis in patients with severe aortic valve disease and correlate FFR- and iFR derived values with those extracted from PET-perfusion Imaging.
The purpose of this study was to compare the effects of limaprost(Opalmon® ) on walking ability, low back pain and leg pain after transforaminal epidural steroid injection (TFESI) was administered compared to the placebo group.
Central vein stenosis (CVS) is a well-known complication of central venous catheterization, especially after insertion of temporary hemodialysis catheters (tHDC). Incidence and prevalence differ between studies, and exact figures are hard to tell since proper venographies seldom are performed unless the patient is symptomatic. Most tHDC are placed in the jugular or femoral veins as catheters in the subclavian veins have been shown to result in CVS to a greater degree. However, some studies are equivocal and there are several advantages with the subclavian vein such as a lower risk for infectious and thrombotic complications, longer durability (thereby avoiding placement of a new catheter with repeated tissue trauma), increased comfort during insertion and use, less effect on blood flow if the patient moves the head, easier to mobilize. The studies on CVS incidence originate from the 1990s when ultrasound-guided insertions were unheard of and polyurethane catheters were prevalent. The investigators believe that there is less tissue trauma when using ultrasound guidance in real-time. Furthermore, CVS is less common when silicone catheters are used instead of polyurethane catheters. To avoid unnecessary vascular trauma and patient suffering, any pre-existing CVS should ideally be detected before cannulation attempts. A CT scan of the chest with IV contrast is preferred, but this exposes the patient to ionized radiation, is time-consuming and (although debated) may cause contrast-induced nephropathy. A brief ultrasound examination to verify central venous patency would be useful provided it is shown to have an adequate sensitivity for stenosis detection.
To investigate the cognitive decline after standard medical treatment without stenting in Asymptomatic Intracranial Stenosis patients and the underlying neural mechanism by fMRI.
Airway stenting is usually efficient to treat central airway obstruction but can lead to severe and potentially lethal complications (stent migration, obstructive granuloma, perforation, and hemoptysis). 3D customized airway stents (computer-aided conception using CT-scan data), perfectly suited to airway anatomy, should improve the tolerance and safety of airway stenting. We demonstrated in a previous pilot study, dedicated to patients with anatomically complex stenoses the safety of 3D patient-specific stents. These appealing results in highly complex situations suggest the need to evaluate these devices in more common situations. In this study we aim to test our new generation stents in all patients planned for airway stenting. After computer-assisted segmentation of airways (VGStudioMAX 3.0 software), the stenosis is virtually corrected, leading to the conception of a virtual stent (AnatomikModeling, Toulouse), allowing for the fabrication of a mold using a 3D printer. The stent is then built and sterilized (NOVATECH, Berlin) and inserted during rigid bronchoscopy. Close follow up is then conducted, including clinical evaluation after one week, three, six and 12 months; spirometry at one week, 3 months, 6 months and 12 months and chest CT-scan at one week.
Biliary stenosis not associated with a mass is difficult to diagnose with certainty. The diagnosis is usually based on a first-line cytological study of biliary brushing, which allows a diagnosis in 30 to 50% of cases. In the event of negativity, it is then possible to perform a cholangioscopy in a second step, which allows better sensitivity by performing biopsies. Performing cholangioscopy from the start could potentially save time and avoid disturbances associated with intermediate biliary stenting. The main objective is to compare two strategies for exploring indeterminate biliary stenosis (1st vs. 2nd line retrograde cholangioscopy) in terms of diagnostic performance. The secondary objectives are to compare the same two strategies in terms of effectiveness, side effects and cost-effectiveness. The primary outcome measure is the diagnostic yield (performance) of the initial investigation of indeterminate biliary stenosis: cytological brushing followed by cholangioscopy in case of failure (control group) or cholangioscopy from the start (study group).