Clinical Trials Logo

Congenital Aniridia clinical trials

View clinical trials related to Congenital Aniridia.

Filter by:
  • None
  • Page 1

NCT ID: NCT05909735 Recruiting - Clinical trials for Limbal Stem-cell Deficiency

Treatment of LSCD With DM

Start date: November 30, 2023
Phase: Phase 1
Study type: Interventional

Limbal Stem Cell Deficiency (LSCD) is a blinding disease that accounts for an estimated 15-20% of corneal blindness worldwide. Current treatments are limited. Traditional corneal transplantation with penetrating keratoplasty (PKP) is ineffective in treating these patients. Without a healthy population of limbal stem cells (LSC) to regenerate the corneal epithelium, standard corneal transplants will not re-epithelialize and will rapidly scar over or melt. The limbal niche is the microenvironment surrounding the LSCs that is critical for maintaining their survival and proliferative potential under physiologic conditions. Extracellular signals from the microenvironment are critical to the normal function and maintenance of pluripotent stem cells. Identifying an effective niche replacement is thus an important focus of limbal stem cell research and critical for advancing treatments for LSCD. Descemet's membrane (DM), an acellular, naturally occurring, basement membrane found on the posterior surface of the cornea, is a promising niche replacement. DM is routinely isolated and transplanted intraocularly with associated donor corneal endothelium for treatment of diseases like Fuchs' dystrophy and corneal bullous keratopathy that specifically affect DM and corneal endothelium. However, its application on the ocular surface has not been explored. DM is optically clear and highly resistant to collagenase digestion. This makes it very attractive as a long-term corneal on-lay and niche replacement on the surface of the eye. The anterior fetal banded layer of DM shares key compositional similarities with limbal basement membrane, which is a major component of the limbal niche. These similarities include limbus-specific extracellular matrix proteins such as collagen IV that is restricted to the α1, α2 subtypes, vitronectin, and BM40/SPARC. Of these, vitronectin and BM40/SPARC are known to promote proliferation of LSCs and induced pluripotent stem cells (iPSC) in culture. Because of this, DM is a promising biological membrane for establishing a niche-like substrate on the corneal surface in patients with LSCD. The purpose of this pilot study is to investigate the clinical efficacy of using DM as a corneal on-lay to promote corneal re-epithelialization in partial LSCD.

NCT ID: NCT05390801 Recruiting - Congenital Aniridia Clinical Trials

Congenital Aniridia Patient Questionnaire

Aniridia-Quizz
Start date: June 8, 2023
Phase:
Study type: Observational

Congenital aniridia is a pan-ocular genetic disease characterized by a partial or complete absence of the iris, hence its name. The prevalence ranges from 1 / 40,000 to 1 / 96,000 births, but it may be underestimated. This condition combines several types of eye damage and could associate systemic manifestations, with a variable phenotype and genotype. This study aims to identify eye and systemic manifestations in congenital aniridia and to determine the patients' knowledge of their own disease through a survey prepared by ophthalmologists from the Ophthalmology Department of Necker-Enfants Malades Hospital, reference center in France for this pathology. The patient fills it out only once.

NCT ID: NCT02945176 Completed - Clinical trials for Graft vs Host Disease

Safety and Performance Study of the ARGOS-IO System in Patients Undergoing Boston Keratoprosthesis Implantation

Start date: March 2015
Phase: N/A
Study type: Interventional

The ARGOS-IO pressure sensor is intended to be implanted in the human eye in combination with Boston Keratoprosthesis (BKPro) surgery and to remain in place indefinitely. It is intended to be used together with the hand-held Mesograph reading device to telemetrically measure the intraocular pressure (IOP) of patients with a BKPro. The purpose of this study is to evaluate the safety and performance of the ARGOS-IO system in patients undergoing concomitant implantation of a BKPro and an ARGOS-IO sensor over the 12 month period beginning at implantation.