Clinical Trials Logo

Clinical Trial Summary

The aim of this single-center randomized controlled trial is to assess clinical usefulness of positron emission tomography combined with computed tomography (PET CT) in the diagnostic process of suspected cardiovascular implantable electronic device (CIED) infection (lead dependent infective endocarditis, generator pocket infection, fever of unknown origin).


Clinical Trial Description

Cardiovascular implantable electronic device (CIED) infection is a complication of increasing incidence. The prevalence of CIED infection is estimated at 2%, with differences between authors ranging from 0.13% to 19.9%.

According to European Heart Rhythm Association survey conducted in high volume centers prevalence of CIED infections was below 2%. The majority of centers were able to isolate the infectious agent in ≤50% of blood cultures which underscore the difficulty in finding the agent of CIEDs infection in many cases.

Cardiovascular implantable device infections can be categorized into 3 groups: superficial skin infection, generator pocket infection and intravascular infection with intact generator pocket. Although local pocket infection is the most common clinical infection occurring early after implantation, positive blood cultures may be the only sign of late onset intravascular infection Mortality in cardiovascular implantable electronic device related infective endocarditis treated with antibiotics only reaches 66%, whereas with combined therapy (antibiotics and complete device removal) it is 3-fold lower.

Prolonged targeted antibiotic therapy (4 to 6 weeks) with complete device removal and revision of indications for re-implantation is recommended in most cases (class I with confirmed diagnosis and IIa with probable diagnosis).

In complicated and uncertain cases additional diagnostic tools are needed, especially if we take into account the load of the patient associated with device removal, prolonged hospitalization and re-implantation.

Apart from morbidity and mortality, infections are also associated with significant financial cost for patients and third-party payers. Polish data on this issue are not available yet but in US the estimated average cost of combined medical and surgical treatment of CIED-related infection ranges from USD 25,000 for permanent pacemakers to USD 50,000 for implantable cardioverter-defibrillators.

Positron emission tomography combined with computed tomography (PET CT) can play an important role in difficult cases of CIED-related infections but published studies focused on the outcomes and safety of this procedure only briefly considering the economical aspect of this diagnostic test.

Recent studies show that PET CT scan is effective and precise tool that can facilitate diagnostic process and decision making regarding therapy especially in difficult patients with CIED-related infections. PET CT scan can protect patients from unnecessary device removal or from too late removal. PET CT may also help in diagnosing other sources of infection, embolic complications, neoplasms, autoimmune diseases and connective tissue diseases.

However there are some issues concerning low sensitivity connected with elevated marker uptake in myocardium and in case of small vegetations, especially lead-related In most studies assessing PET CT in diagnostic process of CIED related infections standard oncologic protocols were used. Those protocols may not be optimal to assess FDG uptake by inflammatory cells.

The aim of this single-center randomized controlled trial is to assess clinical usefulness of positron emission tomography combined with computed tomography (PET CT) in the diagnostic process of suspected cardiovascular implantable electronic device (CIED) infection (lead dependent infective endocarditis, generator pocket infection, fever of unknown origin).

All patients participating in the study will undergo standard diagnostic process. Conventional/standard diagnostic and therapeutic process will consist of: medical interview, physical examination, laboratory tests, blood cultures (3 sets, 1 hour apart, repeated after 24 hours and -if applicable - with fever peak above 38°C); imaging studies (echocardiography: transthoracic, and if there are no contraindications transesophageal, in case of negative or equivocal result repeated after 7-10 days, or in series if necessary, computed tomography scan for pulmonary embolism if indicated); if there are abnormalities in other systems, decisions concerning further diagnostics will be made by the physician in charge.

Apart from standard diagnostic procedures patients will undergo whole body PET CT scan to localize infection or inflammation.

Then the investigators team will make a decision concerning further treatment (antibiotics and complete device removal vs conservative treatment). ;


Study Design

Observational Model: Case Control, Time Perspective: Prospective


Related Conditions & MeSH terms


NCT number NCT02196753
Study type Observational
Source Institute of Cardiology, Warsaw, Poland
Contact Maciej Sterlinski, MD, PhD
Phone 223434050
Email msterlinski@poczta.onet.pl
Status Recruiting
Phase N/A
Start date March 2014
Completion date March 2017

See also
  Status Clinical Trial Phase
Recruiting NCT02246153 - Laparoscopy-assisted and Open Distal Gastrectomy for Gastric Cancer in the Elderly Patients Phase 3
Recruiting NCT02228473 - Effect of Glycopyrrolate and Atropine on Catheter-Related Bladder Discomfort N/A
Recruiting NCT01917253 - Standard Length Catheters vs Long Catheters in Peripheral Vein Cannulation. N/A
Completed NCT02245854 - Efficacy and Safety of a New Polypectomy Snare for Cold-polypectomy for Small Colorectal Polyps N/A
Completed NCT02447523 - The Impact of Metabolic Syndrome on Patients Undergoing Elective Laparotomy N/A
Completed NCT01574196 - Assessment of Cardiac Autonomic Function in Adulthood After Chemotherapy or Radiotherapy in Childhood N/A
Terminated NCT00616824 - The Use of an Acellular Dermal Matrix in a Two-Staged Breast Reconstruction Phase 4
Completed NCT04061655 - Effect of Intravenous Iron Supplementation in Reducing Allogenic Blood Transfusion Early Phase 1
Recruiting NCT03984747 - Study for the Prediction of Active Rejection in Organs Using Donor-derived Cell-free DNA Detection
Completed NCT03641365 - Sleeves Versus Sleeveless Template N/A
Completed NCT02901665 - Impact of Increased Parent Presence in the Neonatal Intensive Care Unit on Parent & Infant Outcomes N/A
Completed NCT02675166 - Getting Long-term Management of Adult Children Cured of Childhood Cancer in Rhône-Alpes
Completed NCT01997658 - Preoperative Glucocorticoid Use in Major Hepatectomy Phase 2/Phase 3
Not yet recruiting NCT02252445 - Propofol and Sevoflurane for Catheter-Related Bladder Discomfort N/A
Active, not recruiting NCT01775150 - Saving Mother and Baby With Text Messaging N/A
Completed NCT01631799 - Outcome of Patients After Total Knee Replacement: A Comparison of Femoral Nerve Block and Epidural Anesthesia N/A
Completed NCT03440138 - Defining Benchmarks in Bariatric Surgery
Recruiting NCT02835404 - Pelvic External Combined With 252-Cf Neutron Intracavitary Radiotherapy With or Without Platinum in Treating Advanced Cervical Cancer Phase 2
Completed NCT01489800 - The Impact of Early Feeding After Radical Cystectomy for Bladder Cancer N/A
Completed NCT02096224 - Sevoflurane Versus Desflurane for Catheter-related Bladder Discomfort N/A