Clinical Trials Logo

Clinical Trial Summary

Atrial fibrillation (AF) is a common debilitating heart rhythm condition that can cause heart failure and negatively impact a patient's outlook in terms of symptoms and disability. It is an irregular fast heart rhythm disorder coming from the top chamber of the heart (left atrium). Catheter ablation treatment has been shown to be effective in controlling or eliminating AF and its associated symptoms. This is now a common and effective treatment option for patients suffering with AF. During ablation, thermal energy is applied in the top chamber of the heart (the left atrium) to abolish abnormal electrical signals that cause AF. It is generally a safe procedure, but one potential risk associated with this procedure is damage to the oesophagus caused by thermal energy being transmitted to the oesophagus from the heart. The oesophagus sits just behind the heart chamber where ablation work is performed, about 5mm away, so it is vulnerable to damage. Although the risk of severe oesophageal damage is low, if it occurs it can be serious as the patient may become very ill as a result. In a recent study, it was shown that a more advanced type of oesophageal probe that cools the oesophagus during ablation is better at protecting the oesophagus from ablation-related injury compared to the standard care probe currently used. As it was a single-centre study, more evidence is required before knowing if this type of probe is more effective in protecting the oesophagus. The purpose is to run a multi-centre randomized study to compare the safety of AF ablation when there is protection by the oesophageal cooling probe versus the standard of care oesophageal temperature monitoring probe. This means that there is a 50:50 chance of the new cooling probe being used during AF ablation for participants.


Clinical Trial Description

The purpose of this research project is to investigate the use of an oesophageal cooling probe as a new and potentially better method of oesophageal protection for AF ablation patients compared to standard care. This is the multi-centre version of the recently completed single-site study (IRAS ID: 253844). This multi-centre version is required to confirm if the oesophageal cooling probe is definitively superior to standard care in protecting AF ablation patients and to clarify the extent of this protection. At present, the method of protection is limited; an oesophageal temperature monitoring probe is inserted whilst the patient is under general anaesthesia and the temperature is measured during ablation, stopping if temperatures markedly increase, which may suggest significant oesophageal thermal injury. This method is unreliable as the temperature probe does not sit well in the oesophagus and is often too far away from the area requiring monitoring. The probe is difficult to place as it can coil. The design of the project is in the form of a randomised controlled trial like the single-centre study, so participants will have a 50:50 chance of being allocated to the study group receiving the new oesophageal cooling probe or the standard care (or control) group, receiving the oesophageal temperature monitoring probe. The patient is blinded to the result of the randomization, to avoid bias/placebo effect. If enrolled to the study group, the oesophageal cooling probe will be used- called the ensoETM probe. This is a smooth medical-grade silicone multi-lumen oesophageal probe (the device has a CE mark and is designed for the purpose of oesophageal insertion and cooling) that allows water irrigation in a closed loop system, when connected to an external console. If the console cools the irrigated water (this is controlled by manual up/down buttons depending on what temperature is desired), the oesophageal probe is then cooled also, which allows local oesophageal wall temperature to be controlled. Oesophageal cooling via the ensoETM probe can then counteract any transmitted thermal energy from the ablation. This probe is already in clinical use in critical care patients where it can control body temperature, if the probe is left in situ for purposely extended hours or days. It is therefore already known to be safe; it also has a good safety profile in the context of AF ablations based on experience from the single-centre study (IRAS ID: 253844; in press- doi:10.1093/europace/euaa276). In the single-centre study, all participants had endoscopic examination after their ablation to review the oesophagus, and no device/probe related abrasive trauma was seen. The procedure is normally done under general anaesthetic so the participant will not be aware of this and will not be subjected to any sensation of pain or discomfort. The probe is soft and much gentler than the camera probe that the team normally have to insert during the catheter ablation procedure (the camera probe or transoesophageal echocardiography, TOE- is part of standard care), so the study authors are of the opinion that this additional precautionary measure does not itself increase the patient's risk or exposure to harm. After the procedure, all participants (study or control) will have an endoscopy camera between 12-72 hours after the catheter ablation procedure to review for degree of oesophageal thermal damage caused by ablation, if any. (Please note: A biopsy is NOT part of this research protocol; this is simply a diagnostic camera.) The endoscopist is also blinded to the result of the randomization to avoid bias during reporting of the endoscopy result. The short time window between ablation and endoscopy camera follow up means that it can be done at the same admission as the ablation procedure itself, this is advantageous for the patient as both the ablation treatment and the follow up camera can be completed in 1 hospital admission. The endoscopy camera result is explained to the patient on the day and if any further action required. The timing is also advantageous to minimise separate hospital attendances in the Covid-19 era. After this, normal/standard care clinic follow up of the patient will be adhered to but as part of the trial, at the first clinic follow up, participants in both groups will be asked about any lingering gastro-oesophageal symptoms and a record is made of this, for the study. The patient is still blinded to the results of the randomization at the time of reporting their symptoms during recovery, if any. This is to avoid bias/placebo effect. The research project does not create any areas of ethical concern as the soft oesophageal cooling device/probe is of gentle design, specifically made to sit in the oesophagus. Especially when compared to the TOE probe that is normally used as part of standard protocol for an AF ablation procedure. The patient will also not be aware of this step at all as the procedure is conducted under general anaesthesia. The device is appropriately CE marked and used for the indication of body cooling via the oesophagus and protection. Even in standard care, an oesophageal temperature monitoring probe is required, so effectively, this study simply randomizes the patient to either the new probe or the standard of care one, during their AF ablation. There is one additional follow up the participant is required to have, as part of this trial: the endoscopy camera (regardless of if randomised to study or control group). The endoscopy camera will be completed by 12-72hrs post catheter ablation procedure. The purpose is to review any areas of inflammation or thermal injury in the oesophagus that may alter clinical management but this specific information will also be used during study analysis of the 2 randomized groups after the study has completed. An endoscopy camera is considered to be a low risk day case procedure that takes 20 minutes to complete. The risk of this camera test causing any damage itself is <0.5%. A TOE probe/any other oesophageal probe used during the ablation procedure is similar to the endoscopy probe so apart from the participant having to attend an additional appointment after their ablation, the overall risk to the patient is not significantly increased. The follow up endoscopy camera may be slightly uncomfortable in the beginning but it is not painful, is straightforward and relatively quick- this will be explained in the beginning during the recruitment process so the potential participant has an accurate idea of what to expect from the endoscopy camera and if they are happy to be enrolled. There is added benefit to the patient from this follow up, as the endoscopy camera will confirm to the patient about any oesophageal injury from ablation and if any treatment is required. If no injury, this can help to reassure the patient before they go home. Lastly, the follow up clinics will be as normal for the participant, only that investigators will ask specifically for any ongoing gastrooesophageal symptoms as well. A record of this will be made. The study authors reviewed the steps involved with this study design and conclude that no major ethical or legal issue has been identified. The summary of the steps involved here hopefully clarifies our viewpoint. From a management perspective, our centre is designed to conduct catheter ablation procedures for AF with general anaesthetic cover. The authors have experience and acquired the necessary equipment from the oesophageal cooling device company and have appropriate device management protocols and storage space in place. External funding for the project has been secured to cover for the additional cost of the oesophageal cooling devices. The endoscopy department at the centre is also equipped and supportive of this study and are able to conduct the additional follow up endoscopy tests post ablation. The team are already accustomed to endoscopy test requests from the department, due to strong clinical indication, post catheter ablation. Lastly, the authors have conducted this proposed research trial at a single-site setting to great success and with excellent safety record with no probe-related trauma and the team did not encounter any new or unexpected issues or difficulties. The authors obtained good patient feedback from the single-centre study. This same trial will run at 5 sites across the UK with potential to further expand depending on statistical analysis. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04577859
Study type Interventional
Source Advanced Cooling Therapy, Inc., d/b/a Attune Medical
Contact Patrick Shanley, MS
Phone (888) 534-4873
Email pshanley@attune-medical.com
Status Recruiting
Phase N/A
Start date March 10, 2022
Completion date March 10, 2025

See also
  Status Clinical Trial Phase
Not yet recruiting NCT04576234 - Comparative Study Between Two Routes of Enteral Feeding N/A
Completed NCT01823328 - Ketamine Versus Etomidate for Rapid Sequence Intubation Phase 4
Recruiting NCT05428618 - Mobile Application for Bariatric Surgery Patients N/A
Completed NCT05710796 - AN OBSERVATIONAL STUDY ON CARDIOVASCULAR INVOLVEMENT IN COVID RECOVERED PATIENTS
Recruiting NCT04921540 - Ingrown Toenails : Surgery Only Versus Surgery + Chemical Cauterization With TCA N/A
Completed NCT05770583 - The Effectiveness of FiO2 Titration Guided by the Oxygen Reserve Index in Preventing Hyperoxia. N/A
Recruiting NCT04037995 - Real World Study of End-stage Liver Disease in China
Completed NCT04256590 - Tongue Depressor-related Tongue Swelling
Active, not recruiting NCT03776591 - Open D3 Right Hemicolectomy Compared to Laparoscopic CME for Right Sided Colon Cancer N/A
Completed NCT03708874 - Pain Management of Emergency Laparoscopic Cholecystectomy in Patients With Acute Cholecystitis
Completed NCT01519362 - A Woman Suffered From Leukocytopenia and Widespread Migration After Polyacrylamide Hydrogel (PAAG) Injection in Epicranial Aponeurosis N/A
Completed NCT02937610 - Percutaneous Endoscopic Gastrostomy in Hands of ORL-HN Surgeon N/A
Completed NCT04487509 - Incidence Study on Acute Coronary Disease With ST Segment Elevation
Terminated NCT05518474 - Self-proning and Repositioning in COVID-19 Outpatients at Risk of Complicated Illness N/A
Recruiting NCT03716089 - Comparison of Tumor Efficacy Safety in Laparoscopic Resection of Gastrointestinal Stromal Tumors Between Favorable and Unfavorable Site
Active, not recruiting NCT04443465 - Patient Experiences of IONM and Outcomes
Recruiting NCT03865537 - Cold Snare Endoscopic Mucosal Resection Trial N/A
Active, not recruiting NCT03860090 - Efficacy and Safety in Pacemaker and Defibrillator Implantation Via Cephalic Versus Axillary Vein Access (CEPHAX) N/A
Recruiting NCT05780775 - Lipid Balance in Adult Sickle Cell Patients N/A
Completed NCT02594891 - Effect of 8.5 F Plastic Stent Without Proximal Flap on Prevention of Post-ERCP Cholangitis N/A