View clinical trials related to Colonic Polyps.
Filter by:CCIS is a novel score, created specifically to evaluate the completeness of caecal visualized. It can be applied to a single or multiple images. To create the CCIS, the caecum was divided into eight parts: the appendiceal orifice (AO), the tri-radiate fold part 1 (TF-1), 2 (TF-2), 3 (TF-3) and four outer quadrants (OQ 1-4). The ileo-caecal valve (ICV) is a reference point but is not part of the score. The quadrant adjacent to the ICV is labelled OQ1. The three other quadrants are labelled clockwise from this quadrant. The tri-radiate folds are also labelled clockwise with TF1 representing the triangle side that is majority-contained within OQ1. TF2 and TF3 are then labelled clockwise from TF1.
It is estimated that about 20% of colonoscopies have inadequate preparation. (5) This is associated with lengthy procedures and less detection of adenomas, reduces the screening intervals, and increases the costs and risks of complications. Several strategies have been proposed to improve the quality of bowel preparation. Mobile healthcare Apps have been developed to increase adherence to bowel preparation agents, improving the quality of bowel preparation. However, adherence to mobile healthcare Apps is also a quality criterion and a pending problem to solve with this new technology. GastroBot is a new technology based on artificial intelligence that allows, through a software bot, to carry out a personalized follow-up of the patient's bowel cleansing, advising the patient to overcome contingencies that arise with the preparation, which in other circumstances could lead to the failure of it. The primary aim of this study is to determine the improvement in bowel preparation after GastroBot assistance compared with the traditional explanation. As a secondary aim, this study also pursues to determine adenoma and polyp detection rates (ADR and PDR, respectively), bowel preparation agents' tolerance, and GastroBot functionality.
The present trial is aimed at evaluating whether in individuals scheduled for colonoscopy in the framework of a structured FIT (Fecal Immunochemical stool test)-based colorectal cancer screening program, the combination of an AI (artificial intelligence) system (CADEYE) with a mucosal exposure device (G-EYE 760R endoscope) increases the identification of subjects at high risk to develop colorectal cancer (according to recent ESGE-European Society of Gastrointestinal Endoscopy guidelines subjects are labelled as "high-risk" if harboring at least 1 adenoma ≥ 10 mm or with high grade dysplasia, or ≥ 5 adenomas, or any serrated polyp ≥ 10 mm or with dysplasia) when compared to colonoscopy performed with the support of AI only. Individuals fulfilling inclusion criteria are randomized (1:1) to two different arms (Control arm and Interventional arm, see below). Randomization is based on a computer-generated randomized block sequence, stratified according to age (50-61 vs. 62-74) and gender (male vs. female); size of the blocks (10 individuals) is not communicated to the investigator. Allocation is concealed and kept in a sealed envelope, which is opened just before starting colonoscopy. Individuals randomized in the Intervention arm receive colonoscopy examination with G-EYE 760R colonoscopes; once the cecum is reached the balloon is inflated, and the endoscope is withdrawn with the inflated balloon; the colonoscopy is performed with the support of the CADEYE system for polyp detection in both insertion and withdrawal phase; all polyps identified are removed and sent for histopathology examination. Individuals randomized in the Control arm (CADEYE only) receive colonoscopy with G-EYE 760R colonoscope but the balloon remains deflated for the entire procedure; the colonoscopy is performed with the support of the CADEYE system for polyp detection in both insertion and withdrawal phase; all polyps identified are removed and sent for histopathology examination. The main outcome measure is the rate of "high risk" individuals across the two study arms.
Background: Removal of adenomatous polyps during colonoscopy is associated with long-term prevention of colorectal cancer-related deaths. Recently, there have been much interest in the use of artificial intelligence (AI) platforms to augment the routine endoscopic assessment of the colon to enhance adenoma detection rate (ADR). To date, computer assisted detection of polyps (CADe) have been shown to be safe, with a significant increase in ADR, without any concomitant increase in post-procedural complications. Aims: The investigators aim to evaluate the use of GI GeniusTM Intelligent Endoscopy Module in a multi-ethnic Asian population (Singapore) to increase in ADR and adenoma detected per colonoscopy (ADPC)to justify its effectiveness as an adjunct in polyp detection and training for colonoscopy. Methods: This study will be a single-institution cohort study, conducted over a 2-year period. Sengkang General Hospital (SKH) does an estimated 12,500 colonoscopies per year, with an average of 1,040 colonoscopies performed every month. Thus, given the case volume, the investigators expect to detect differences in ADR amongst endoscopists if any during this study period. As part of the subgroup analysis, the investigators also aim to compare the ADR rates of trainee endoscopists with and without the GI GeniusTM Intelligent Endoscopy Module to ascertain its utility as an education tool/training adjunct
To conduct an single blinded, non-randomized, prospective, single center trial to validate the performance of a novel state-of-the-art Artificial Intelligence model (AI-Model) for colorectal lesion detection during routine diagnostic colonoscopy and to evaluate its feasibility in daily endoscopy. Consecutive patients referred for a screening, surveillance or diagnostic colonoscopy will be included
Management of unexpected malignant colorectal polyps removed endoscopically can be challenging due to the risk of residual tumor and lymphatic spread. International studies have shown that in patients choosing surgical management instead of watchful waiting, 54-82% of bowel resections are without evidence of residual tumor or lymphatic spread. As surgical management entails risks of complications and watchful waiting management entails risks of residual disease or recurrence, a clinical dilemma arises when choosing a management strategy. Shared decision making (SDM) is a concept that can be used in preference sensitive decision making to facilitate patient involvement, empowerment, and active participation in the decision making process. This is a clinical multicenter, non-randomized, interventional phase II study involving Danish surgical departments planned to commence in the first quarter of 2024. The aim of the study is to examine whether shared decision making and using a patient decision aid (PtDA) in consultations affects patients' choice of management compared with historical data. The secondary aim is to investigate Patient Reported Experience Measures (PREMs) and Patient Reported Outcome Measures (PROMs) using questionnaire feedback directly from the patients.
The ClearCoajet is a new hemostasis device with a hybrid function (Coagulation + Injection) and is developed to provide effective coagulation, injection, and marking around lesions without changing devices during the endoscopic procedure. In this study, the investigators examine the hemostatic effect of ClearCoajet on intraprocedural bleeding during endoscopic mucosal resection or endoscopic submucosal dissection for colorectal sessile polyps or lateral growth tumors larger than 1.5 cm. The investigators also aim to compare the delayed bleeding and recurrence rates between the ClearCoajet group and the control group.
Ultivision AI is a computer-assisted detection (CADe) device intended to aid endoscopists in the real-time identification of colonic mucosal lesions (such as polyps and adenomas). Ultivision AI CADe is indicated for white light colonoscopy only.
The EAGLE study is a prospective randomized controlled multicenter parallel design trial, for the assessment of clinical performance of the CADDIE device and to confirm that the device performs as expected.
The investigators hope that this project will determine if the Endocuff device is a useful adjunct during colonoscopy by optimizing polyp detection and eliminating the need for the painful rectal retroflexion. As such, by improving polyp detection and eliminating the need for rectal retroflexion, it will directly reduce the likelihood of colon cancer and improve patient comfort respectively.