Colon Cancer Clinical Trial
Official title:
Prospective Study for Evaluating Colon Polyp Histology With in Vivo Probe Based Confocal Laser Endomicroscopy
Chromoendoscopy (that involves spraying of dyes over the colonic mucosa) combined with
magnification has been utilized for polyp histology identification. Pit patterns on the
surface of polyps described by Kudo et al have been shown to have a high diagnostic accuracy
in differentiating the polyp types (18, 19). NBI, that is also referred to as "electronic
chromoendoscopy" is another technique that has been evaluated for polyp histology
identification by highlighting the superficial mucosal and vascular architecture (15, 20,
21). pCLE is another novel addition to the technologies aiming to accomplish in vivo
histologic diagnosis with a high degree of accuracy. The pCLE system has three major
components (Mauna Kea Technologies, Paris, France). The first is the confocal miniprobe made
of approximately thirty thousand optical fibers bundled together and terminated by a distal
microsystem. The images obtained have a lateral resolution of 1µm, an axial resolution of 10
µm and a maximum field of view of 240 µm. The depth of observation is from 55 to 65 µm. The
miniprobe tip diameter is 2.5 mm and can be passed through the accessory channel of any
standard endoscope. The second is the laser scanning unit (excitation wavelength - 488 nm)
that combines the functions of laser light illumination and rapid laser scanning, enabling a
frame rate up to 12 images per second and signal detection. The third is the control and
acquisition software for real time image reconstruction, immediate sequences display and
post-procedure analysis and editing tools. Once an area of interest (e.g. a polyp) is
identified, 5 ml of 10% fluorescein sodium is injected intravenously; the confocal probe is
passed through the accessory channel of the endoscope and placed against the lesion to
obtain several high-quality images and video sequences. In a study by Buchner et al from the
Mayo Clinic, Jacksonville, (22) this system was used to evaluate confocal images of 37
polyps from 25 patients in a blinded fashion without the knowledge of their histologic
diagnosis or endoscopic appearance. The investigators developed the following criteria that
were suggestive of neoplastic polyps: villiform pattern, nuclear characteristics -
oval/irregular nuclear shape and increased number of nuclei. These features had a
sensitivity of 82.6%, specificity of 92.9% and accuracy of 86.5% for the characterization of
neoplastic polyps. Similarly, Meining et al (23) have also evaluated criteria for
differentiating neoplastic from benign lesions in the colon with encouraging results.
The investigators hypothesize that pCLE will have a high rate for accurate characterization
of polyp histology real time during colonoscopy
This study will be conducted at the Kansas City VA Medical Center, Kansas City, MO. The
investigators have the pCLE system that the investigators are currently using in a
multicenter study evaluating patients with Barrett's esophagus. Patients referred for
screening and/or surveillance colonoscopy will be prospectively enrolled in this study.
Inclusion criteria - referral for screening and/or surveillance colonoscopy and the ability
to provide informed consent. Exclusion criteria: prior surgical resection of any portion of
colon, prior history of colon cancer, history of inflammatory bowel disease, use of
anti-platelet agents or anticoagulants that precludes removal of polyps during the
procedure, poor general condition or any other reason to avoid prolonged procedure time,
history of polyposis syndrome or HNPCC, inability to give informed consent, inadequate bowel
preparation, allergy to fluorescein, pregnancy, and renal insufficiency. Moderate sedation
for the procedure will be administered in a standard fashion with intravenous midazolam,
meperidine or fentanyl. This will be a single arm study with all procedures being performed
with a standard white light colonoscope (CF - H180AL, Olympus America). After cecal
intubation, the colonic mucosa will be carefully visualized during withdrawal under
high-definition white light and if a polyp is detected, its characteristics will be
documented: size, location, and morphology [Polypoid (sessile, pedunculated) or
Non-polypoid: (superficial elevated, completely flat, depressed)]. Then 5ml of 10%
fluorescein sodium will be injected intravenously. Following this the pCLE probe will be
passed through the biopsy channel of the colonoscope and placed on the polyp to obtain
confocal images and video sequences. During the initial phase unblinded comparisons of the
confocal images and videos with the polyp histology (20 adenomas, 20 hyperplastic) will be
performed in order to evaluate the criteria described by the Mayo Jacksonville group (22)
that differentiate between neoplastic and non neoplastic polyps. Following this initial
phase, these criteria will be applied in a prospective manner to predict polyp histology
(100 polyps) real time during the procedure prior to their removal. Multiple confocal images
and videos of each polyp will be saved with appropriate labeling. Pathologists will be
blinded to the endoscopic and pCLE findings of the polyps. Polyp size will be assessed by
comparing with sheath of a polypectomy snare or open span of a biopsy forceps. Photo
documentation of the polyps will be performed. Polyps will then be removed in the standard
fashion with a biopsy forceps or snare and sent for histopathological evaluation. Each polyp
will be sent in a separate jar and labeled accordingly. The bowel preparation will be
evaluated and graded according to previously reported criteria (24): excellent, good, fair,
and inadequate. Patients with inadequate bowel preparation will be excluded. Complications
including gastrointestinal bleeding (requiring intervention) and perforation will be
recorded.
Outcomes:
The predicted histology of polyps based on the confocal images and videos and the
correlation with actual histology for accuracy of prediction will be the primary outcome.
Secondary outcome will be the inter-observer variability in polyp histology prediction based
on the confocal images and videos of polyps (by kappa statistics).
;
Allocation: Non-Randomized, Endpoint Classification: Efficacy Study, Intervention Model: Single Group Assignment, Masking: Single Blind (Outcomes Assessor), Primary Purpose: Screening
Status | Clinical Trial | Phase | |
---|---|---|---|
Active, not recruiting |
NCT05551052 -
CRC Detection Reliable Assessment With Blood
|
||
Completed |
NCT03457454 -
Reducing Rural Colon Cancer Disparities
|
||
Recruiting |
NCT06006390 -
CEA Targeting Chimeric Antigen Receptor T Lymphocytes (CAR-T) in the Treatment of CEA Positive Advanced Solid Tumors
|
Phase 1/Phase 2 | |
Active, not recruiting |
NCT04088955 -
A Digimed Oncology PharmacoTherapy Registry
|
||
Recruiting |
NCT06010862 -
Clinical Study of CEA-targeted CAR-T Therapy for CEA-positive Advanced/Metastatic Malignant Solid Tumors
|
Phase 1 | |
Terminated |
NCT01347645 -
Irinotecan Plus E7820 Versus FOLFIRI in Second-Line Therapy in Patients With Locally Advanced or Metastatic Colon or Rectal Cancer
|
Phase 1/Phase 2 | |
Completed |
NCT03390907 -
Hybrid APC Assisted EMR for Large Colon Polyps
|
N/A | |
Recruiting |
NCT03175224 -
APL-101 Study of Subjects With NSCLC With c-Met EXON 14 Skip Mutations and c-Met Dysregulation Advanced Solid Tumors
|
Phase 2 | |
Completed |
NCT04079478 -
The AID Study: Artificial Intelligence for Colorectal Adenoma Detection
|
||
Active, not recruiting |
NCT04057274 -
Acute Effect of modeRate-intensity aerOBIc Exercise on Colon Cancer Cell Growth
|
N/A | |
Recruiting |
NCT03190941 -
Administering Peripheral Blood Lymphocytes Transduced With a Murine T-Cell Receptor Recognizing the G12V Variant of Mutated RAS in HLA-A*11:01 Patients
|
Phase 1/Phase 2 | |
Not yet recruiting |
NCT05147545 -
Impact of Exercise and Hyperlipidic Meal on Free Circulating DNA in Patients With Metastatic Colonic Cancer and Healthy Subjects
|
N/A | |
Recruiting |
NCT05026268 -
The Laparoscopic Right Colectomy With Intracoroporeal Anastomosis
|
N/A | |
Not yet recruiting |
NCT03277235 -
Effect of a Resilience Model-Based Care Plan in Newly Diagnosed Colorectal Cancer Patients
|
N/A | |
Active, not recruiting |
NCT02730702 -
Colon Cancer Risk-stratification Via Optical Analysis of Rectal Ultrastructure
|
||
Active, not recruiting |
NCT02959541 -
PK/PD Investigation of Calciumfolinat in Blood, Tumor and Adjacent Mucosa in Patient With Colon Cancer
|
N/A | |
Completed |
NCT02810652 -
Perioperative Geriatrics Intervention for Older Cancer Patients Undergoing Surgical Resection
|
N/A | |
Recruiting |
NCT02577627 -
Multi-Indication, Retrospective Oncological Study to Validate the Accuracy in Predicting TTP by PrediCare in Patients Under SOC
|
N/A | |
Terminated |
NCT02628535 -
Safety Study of MGD009 in B7-H3-expressing Tumors
|
Phase 1 | |
Recruiting |
NCT02526836 -
Complete Mesocolic Excision With Central Vessel Ligation Compared With Conventional Surgery for Colon Cancer
|
Phase 2/Phase 3 |