Clinical Trials Logo

Clinical Trial Summary

This study will test the use of a new device called a segmental stiffening wire (SSW) in colonoscopy to correct a problem called looping. Colonoscopy is the best test for detecting early colon cancer and removing growths called polyps, which can become colon cancer. Sometimes the flexible tube (colonoscope) used in the procedure loops at a certain point as it advances through the colon, making it difficult to move further and causing the patient pain from excessive stretching of the colon. The SSW is designed to prevent this by stiffening the part of the tube that would otherwise form the loop.

Healthy subjects between 50 and 80 years of age and healthy subjects 40 years and older who have a family history of colon cancer may be eligible for this study.

Participants undergo colonoscopy a day after self-administering a bowel cleansing preparation. The first part of the procedure is done similarly to that of a flexible sigmoidoscopy, and no sedation or pain medication is used. The colonoscope is inserted into the rectum and advanced about one-third the length of the colon. Pain or discomfort should be mild to moderate cramping and a feeling of having to move the bowels. The subject is asked to score his or her pain level at this point using a standard pain scale. If there is pain, the procedure is stopped and an x-ray is taken to determine if the colonoscope has looped. If it has, the loop is undone and the SSW is used. Another x-ray is then taken to document that the loop has been prevented with the SSW, and the procedure is completed as per standard medical practice. Subjects are taken to the recovery area, informed of the test results and then discharged home in the care of an accompanying adult.


Clinical Trial Description

Colonoscopy can be challenging to perform and painful due to looping of the colonoscope. Looping occurs when further insertion of the colonoscope results in a loop forming in the shaft of the colonoscope instead of advancement of the tip. Attempts have been made to solve this problem, but to date there is no perfect solution. Since colonoscopy is the gold standard for colon cancer screening providing a device that could prevent looping would be valuable. We have developed an experimental device that has not been approved outside of the context of this study known as the Segmental Stiffening Wire (SSW). This wire will be utilized by passing it through the biopsy channel of the endoscope. The wire has a 15-25 inch area of increased thickness and stiffness. The stiffened section can be advanced into areas of looping in an effort to prevent re-looping. We will conduct a pilot study in two phases. The first phase will include approximately 10 healthy volunteers who will undergo colonoscopy using the SSW. Fluoroscopy will be used to determine if the device prevents re-looping. If in phase 1 the device is successful in over 30% of episodes, the second phase will be undertaken. In the second phase volunteers willing to undergo two colonoscopies on consecutive days will be recruited. Volunteers who experience looping will be randomized as to whether the SSW is available. These volunteers will then undergo an otherwise identical colonoscopy on the following day except the SSW will be available if it was not on the first colonoscopy or it will not be available if it was on the first colonoscopy. Volunteers who undergo two colonoscopies will not need a second bowel preparation but will be maintained on a clear liquid diet between the two procedures. Volunteers in which looping does not occur will have their initial colonoscopy completed as normal and then will leave the study. If unable to obtain sufficient volunteers willing to undergo dual colonoscopy, then volunteers willing to undergo single colonoscopy will be included and their procedures will be done with or without the SSW in random fashion. The endpoints will be cecal intubation time; cecal intubation rate; quantity of sedation/analgesia; number of ancillary maneuvers; pain/sedation as measured by the Visual Analog Pain Scale, the Ramsey Sedation Scale, and clinical observations; vital sign changes; and the endoscopists subjective assessment of procedure difficulty and the usefulness of the SSW. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT00719641
Study type Observational
Source National Institutes of Health Clinical Center (CC)
Contact
Status Completed
Phase
Start date August 5, 2008
Completion date September 21, 2016

See also
  Status Clinical Trial Phase
Completed NCT04101097 - Training and Validation of Models of Factors to Predict Inadequate Bowel Preparation Colonoscopy
Completed NCT03247595 - Testing How Well Magnesium Citrate Capsules Work as Preparation for a Colonoscopy N/A
Completed NCT04214301 - An Open-Label Preference Evaluation of BLI800 Phase 4
Withdrawn NCT05754255 - Comparison of High-flow Oxygen With or Without Nasal Positive Airway Pressure (PAP) During Propofol Sedation for Colonoscopy in an Ambulatory Surgical Center N/A
Recruiting NCT02484105 - Comforting Conversation During Colonoscopy: A Trial on Patient Satisfaction Phase 4
Active, not recruiting NCT02264249 - Residual Gastric Volume in Same Day Versus Split Dose and Evening Before Bowel Preparation N/A
Terminated NCT01978509 - The Affect of Low-Volume Bowel Preparation for Hospitalized Patients Colonoscopies N/A
Completed NCT01964417 - The Comparative Study Between Bowel Preparation Method Phase 3
Recruiting NCT01685970 - Comparison of Same-day 2 Sachets Picosulfate Versus High Volume PEG for Afternoon Colonoscopy Phase 3
Completed NCT01518790 - Short Course, Single-dose PEG 3350 for Colonoscopy Prep in Children N/A
Recruiting NCT00748293 - Achievement of Better Examinee Compliance on Colon Cleansing Using Commercialized Low-Residue Diet N/A
Completed NCT00779649 - MoviPrep® Versus HalfLytely®, Low-VolUme PEG Solutions for Colon Cleansing: An InvesTigator-blindEd, Randomized, Trial Phase 4
Completed NCT00671177 - Clinical Evaluation of Water Immersion Colonoscopy Insertion Technique N/A
Completed NCT00380497 - Pico-Salax Versus Poly-Ethylene Glycol for Bowel Cleanout Before Colonoscopy in Children Phase 4
Recruiting NCT00160823 - Impact of a Self-Administered Information Leaflet on Adequacy of Colonic Cleansing for in-Hospital Patients Phase 3
Completed NCT00314418 - Patient Position and Impact on Colonoscopy Time N/A
Completed NCT00390598 - PEG Solution (Laxabon®) 4L Versus Senna Glycoside (Pursennid® Ex-Lax) 36mg and PEG Solution (Laxabon®) 2L for Large Bowel Cleansing Prior to Colonoscopy Phase 2/Phase 3
Completed NCT00427089 - Comparison of 2L NRL994 With NaP Preparation in Colon Cleansing Prior to Colonoscopies for Colon Tumor Screening Phase 3
Completed NCT00209573 - A Study of AQUAVAN® Injection Versus Midazolam HCl for Sedation in Patients Undergoing Elective Colonoscopy Phase 3
Completed NCT05823350 - The Effect of Abdominal Massage on Pain and Distention After Colonoscopy N/A