Colonoscopy Clinical Trial
Official title:
Adenoma Detection Using Real-Time Computer-Aided Colon Polyp Detection System to Compare Water Exchange and Air Insufflation - A Randomized Controlled Trial
Water exchange (WE) is an effective insertion method to minimize insertion discomfort and maximize ADR. It is characterized by infusing water to guide insertion in an airless lumen with suctioning of infused water during insertion and almost complete removal of the infused water when cecal intubation is achieved. A modified Delphi review reported water exchange showed the highest overall ADR, ADR in screening cases, and in the right side of the colon compared with water immersion and air (or CO2) insufflation. One of the plausible mechanisms of improving ADR by water exchange is salvage cleaning during insertion, which might help artificial intelligence by removing the interference of fecal debris and bubbles. However, no RCT has been performed to evaluate the effect of CADe on WE colonoscopy. Therefore, investigators will conduct a RCT comparing the ADR of CADe assisted colonoscopy inserted with either WE or insufflation. Our hypothesis will be that CADe assisted WE colonoscopy achieves higher ADR than CADe assisted air insufflation colonoscopy.
The primary end point will be ADR, defined as the proportion of patients with at least one adenoma. Serrated lesions will not be counted as part of ADR. Secondary outcomes were FP rate, adenomas per colonoscopy (APC), polyp detection rate, polyps per colonoscopy, SL detection rate, cecal intubation rate, withdrawal time. Missed polyp will be defined as a polyp recognized by endoscopist, but is not detected by CADe system at an interval of 2 seconds. The detected polyps will be classified in sizes, morphology (polypoid or nonpolypoid). Investigators also record the detection of every polyp by the endoscopist or the CADe system in time priority. If a polyp is detected by performing endoscopist at the same time as the CADe system, the credit will go to the endoscopist. The colonoscopy procedure will be recorded as CADe over-laid videos and be reviewed for FP characteristics, numbers and appearance time afterward. The withdrawal time will be divided into inspection time, cleaning time and polypectomy time. Boston Bowel Preparation Scale score and the amount of water infused and aspirated will also be recorded. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT04101097 -
Training and Validation of Models of Factors to Predict Inadequate Bowel Preparation Colonoscopy
|
||
Completed |
NCT03247595 -
Testing How Well Magnesium Citrate Capsules Work as Preparation for a Colonoscopy
|
N/A | |
Completed |
NCT04214301 -
An Open-Label Preference Evaluation of BLI800
|
Phase 4 | |
Withdrawn |
NCT05754255 -
Comparison of High-flow Oxygen With or Without Nasal Positive Airway Pressure (PAP) During Propofol Sedation for Colonoscopy in an Ambulatory Surgical Center
|
N/A | |
Recruiting |
NCT02484105 -
Comforting Conversation During Colonoscopy: A Trial on Patient Satisfaction
|
Phase 4 | |
Active, not recruiting |
NCT02264249 -
Residual Gastric Volume in Same Day Versus Split Dose and Evening Before Bowel Preparation
|
N/A | |
Terminated |
NCT01978509 -
The Affect of Low-Volume Bowel Preparation for Hospitalized Patients Colonoscopies
|
N/A | |
Completed |
NCT01964417 -
The Comparative Study Between Bowel Preparation Method
|
Phase 3 | |
Recruiting |
NCT01685970 -
Comparison of Same-day 2 Sachets Picosulfate Versus High Volume PEG for Afternoon Colonoscopy
|
Phase 3 | |
Completed |
NCT01518790 -
Short Course, Single-dose PEG 3350 for Colonoscopy Prep in Children
|
N/A | |
Recruiting |
NCT00748293 -
Achievement of Better Examinee Compliance on Colon Cleansing Using Commercialized Low-Residue Diet
|
N/A | |
Completed |
NCT00779649 -
MoviPrep® Versus HalfLytely®, Low-VolUme PEG Solutions for Colon Cleansing: An InvesTigator-blindEd, Randomized, Trial
|
Phase 4 | |
Completed |
NCT00671177 -
Clinical Evaluation of Water Immersion Colonoscopy Insertion Technique
|
N/A | |
Completed |
NCT00380497 -
Pico-Salax Versus Poly-Ethylene Glycol for Bowel Cleanout Before Colonoscopy in Children
|
Phase 4 | |
Recruiting |
NCT00160823 -
Impact of a Self-Administered Information Leaflet on Adequacy of Colonic Cleansing for in-Hospital Patients
|
Phase 3 | |
Completed |
NCT00314418 -
Patient Position and Impact on Colonoscopy Time
|
N/A | |
Completed |
NCT00390598 -
PEG Solution (Laxabon®) 4L Versus Senna Glycoside (Pursennid® Ex-Lax) 36mg and PEG Solution (Laxabon®) 2L for Large Bowel Cleansing Prior to Colonoscopy
|
Phase 2/Phase 3 | |
Completed |
NCT00209573 -
A Study of AQUAVAN® Injection Versus Midazolam HCl for Sedation in Patients Undergoing Elective Colonoscopy
|
Phase 3 | |
Completed |
NCT00427089 -
Comparison of 2L NRL994 With NaP Preparation in Colon Cleansing Prior to Colonoscopies for Colon Tumor Screening
|
Phase 3 | |
Completed |
NCT05823350 -
The Effect of Abdominal Massage on Pain and Distention After Colonoscopy
|
N/A |