Coagulopathy Clinical Trial
Official title:
Comparison of the Point-of-care Coagulation Device Quantra With the TEG for Congenital Cardiac Surgery - a Pilot Validation Study
Congenital heart surgery on cardio-pulmonary bypass (CPB) is associated with impacted coagulation quality and increased bleeding after separation of CPB. The current testing device used at our institution is the "TEG 5000" (Haemonetics Corporation). The novel coagulation testing device "Quantra System" (Hemosonics) has favorable properties (result within 20 minutes) allowing for a quicker identification of the coagulation problem and hence faster administration of the correct coagulation products, potentially leading to better coagulation quality and possibly reducing the need of additional blood products. The aim of this prospective observational (non-interventional, investigational only) quality improvement study is to investigate if the Quantra is reliable and valid in predicting the coagulation status when compared with our standard-of-care device TEG 5000.
Congenital heart surgery on cardio-pulmonary bypass (CPB) is associated with impacted coagulation quality and increased bleeding after separation of CPB. Therefore, coagulation products and blood products often need to be given/transfused during these cases. The correct choice and dosing of coagulation products is essential to effectively stop bleeding and reduce the need of additional blood transfusion. The current testing device used at our institution during congenital heart surgery on CPB is the TEG 5000 (Haemonetics Corporation). Prior to separation from CPB (mostly 30-60 minutes) and after the first coagulation products were given (approx. 60 minutes after separation from CPB) a Clauss Fibrinogen and a TEG are drawn. These samples are sent to an off-site lab for processing and time to result ranges from 60-90 minutes. Therefore, results are often not present when needed. An easy to use point-of-care (POC) test device being readily available in the operation room and allowing for rapid results could result in quicker identification of the coagulation problem and hence allow for faster administration of the correct coagulation products, potentially leading to better coagulation quality and possibly reducing the need of additional blood products. The Quantra System (Hemosonics) is an easy-to-use, stand-alone device presenting results within 20 minutes. With these properties all above mentioned problems would be addressed. To date the Quantra has not been used and has not been evaluated in patients with congenital heart disease for cardiac surgery on CPB. The aim of this prospective observational (non-interventional, investigational only) quality improvement study is to investigate if the Quantra is reliable and valid in predicting the coagulation status when compared with our standard-of-care device TEG All patients who are enrolled in this study will be patients who are scheduled to undergo cardiac surgery and who require a general anesthesia, endotracheal intubation, arterial line placement and coagulation testing as part of standard of care for the surgery. No patient will have a general anesthesia, endotracheal intubation, arterial line inserted or coagulation testing for research purposes only. If the family/patient consent to be enrolled in the study the patient will be included in the study. It is standard of care to draw blood samples for coagulation testing (TEG and Clauss Fibrinogen) prior to separation of cardio-pulmonary-bypass (t1) and after the first coagulation products were given (t2), resulting in 2 x 5.4mL of blood. For testing of efficacy/reliability/validity of the Quantra System we will need to draw additional blood samples (2.7mL) for each time point t1 and t2, resulting in a total of 2 x 2.7mL. These extra 5.4mL of blood drawn during the research portion of this study is additional to what they need for the surgical procedure and is not standard of care. No clinical decision will be made on the results of the Quantra System. This is an investigational, non-interventional study. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT01912547 -
Thromboelastography During Surgery for Malignant Pleural Mesothelioma
|
Phase 0 | |
Completed |
NCT03674684 -
ROTEM Assessment of Modern Crystalloid, Hydroxyethyl Starch and Gelatin Effect on Coagulation
|
||
Recruiting |
NCT05874843 -
Validation of Point-of-care Thromboelastography (TEG 6s) in Pediatric Patients
|
N/A | |
Withdrawn |
NCT04705701 -
Comparing Post Cardiac Surgery Outcomes in ESRD Patient's With Early Dialysis Versus Standard Care
|
N/A | |
Not yet recruiting |
NCT04515420 -
The Influence of Noradrenaline on Coagulation and Fibrinolysis in Severe Isolated Brain Injury
|
||
Completed |
NCT01598831 -
Phase 3 Safety and Efficacy Study of ART-123 in Subjects With Severe Sepsis and Coagulopathy
|
Phase 3 | |
Completed |
NCT04580563 -
Study Assessing Efficacy of Plasmatherapy in Septic Shock-induced Coagulopathy: Feasibility Study
|
N/A | |
Withdrawn |
NCT04274699 -
Clinical Evaluation of the Hemosonics Quantra® Coagulation Monitor in Liver and Multivisceral Transplantation
|
||
Terminated |
NCT02540434 -
Trial of RiaSTAP Versus Cryoprecipitate to Lower Operative Transfusions
|
N/A | |
Completed |
NCT02203968 -
Fibrinogen in the Initial Resuscitation of Severe Trauma (FiiRST)
|
Phase 1/Phase 2 | |
Unknown status |
NCT01854476 -
Safety and Efficacy Study Comparing Pad-gauze With Anti-fibrinolytic Agent Hemostopan™) to a Regular Pad-gauze
|
Phase 2/Phase 3 | |
Completed |
NCT00816127 -
Prevention of Bleeding in Patient With Cirrhosis Undergoing Dental Extraction
|
N/A | |
Active, not recruiting |
NCT02926274 -
Transfusion Using Stored Whole Blood
|
N/A | |
Not yet recruiting |
NCT04582188 -
The Early Coagulopathy for the Prognosis in Sepsis
|
||
Recruiting |
NCT04528888 -
Steroids and Unfractionated Heparin in Critically Ill Patients With Pneumonia From COVID-19 Infection
|
Phase 3 | |
Recruiting |
NCT05449834 -
Fibrinogen Early In Severe Trauma StudY II
|
Phase 3 | |
Withdrawn |
NCT04435015 -
The Utility of Camostat Mesylate in Patients With COVID-19 Associated Coagulopathy (CAC) and Cardiovascular Complications
|
Phase 1/Phase 2 | |
Not yet recruiting |
NCT04115722 -
Coagulation Parameters in IBD Patients
|
||
Completed |
NCT01228058 -
A Prospective Evaluation of Thromboelastography for Identifying Coagulopathy in Severely Injured Patients
|
N/A | |
Active, not recruiting |
NCT04128488 -
Effects of Gender-Affirming Hormone Therapy Among Transgender Women
|