Clinical Trials Logo

Clinical Trial Summary

Severe coagulopathy and operative bleeding are common in liver and multivisceral transplant recipients. This is related to reduced synthesis and function of clotting proteins in end-stage liver disease, thrombocytopaenia, thrombocytopathy, accelerated fibrinolysis, portal hypertension, inflammatory adhesions and intraoperative hemodilution. A pro-coagulant state is also a common finding in both groups, sometimes associated with fatal thromboembolism, and the balance between anti- and pro-coagulant effects is easily disrupted by intraoperative events. Use of point-of-care intraoperative viscoelastic testing, capable of discriminating between various potential causes of coagulopathy and of identifying some hypercoagulable states, is now routine in this setting. This has been shown to guide treatment faster and more reliably than standard laboratory screening tests. However, traditional viscoelastic tests based on a pin-and-cup arrangement are sensitive to technical error, movement and physical clot disruption, and the validity of measurements is highly dependent on operator training. A newer method (TEG® 6S) based on light reflection from a blood meniscus reduces scope for operator error but remains sensitive to movement. Measurement of ultrasonic resonance (or 'sonic estimation of elasticity via resonance [SEER] sonorheometry') using the Quantra® analyzer surgery appears to minimize these problems in studies performed in healthy volunteers, in spinal surgery and in both elective and urgent cardiac procedures. Pilot testing in the latter group suggests it may also differentiate qualitatively between fibrinogen and platelet deficiency, but the range of intrinsic coagulation disturbances in this context is limited. This study proposes to assess the validity of the Quantra® analyzer in a population with more extreme coagulopathy, including severe fibrinolysis, and recognized thrombophilic states.


Clinical Trial Description

Blood clotting during surgery is a complex process affected by many factors, including low levels of clotting factors and/or platelets resulting from liver disease, varying levels of factors that promote clotting, medicines that inhibit clotting, dilution of clotting factors by fluids given during surgery, body temperature, haemoglobin levels, inflammation, and tissue factors that speed up the breakdown of newly formed clots. The treatment of excessive surgical bleeding and abnormal clotting (thrombosis) depends on distinguishing between these factors to target the probable cause. Measurement of the blood's 'thickness' (ability to clot) in the operating theatre helps identify the cause and can both indicate the best treatment and monitor the body's response to that treatment. This study will evaluate the ability of a new measurement device using high frequency sound (ultrasound) rebounding from a tiny sample of clotting blood to demonstrate different types of clotting disorder, and to compare it's accuracy to an existing device that works by measuring the stickiness of blood as it clots in a small cup. It will also compare the ability of both devices to match the surgeon's visual assessment of bleeding and clot formation in the surgical wound. A recent National Institute of Clinical Excellence guideline (DG13 - 2014) acknowledges that standard laboratory screening tests are of limited diagnostic value in the setting of cardiac surgery owing both to delays in obtaining results and to their frequent inability to distinguish between causes of abnormal clotting. This guidance recommends point-of-care tests that measure changes mechanical strength of blood clot over time ("viscoelastic testing"), such as the TEG6 device. The new Quantra device measures similar changes in the physical properties of clotting blood using ultrasound, and has recently shown promising results in cardiac surgery. In this setting it appears to help distinguish between low levels of the clotting factor fibrinogen and low platelets as causes of impaired clotting, and may be superior to the TEG6. The present study will assess clotting in a group of patients with more severe clotting abnormalities and much heavier bleeding, and the benefits seen in cardiac surgery may be more marked. Patients having major abdominal organ transplants (liver and liver-intestine transplants) typically have heavy bleeding, as much as all the blood in the body (about 5 litres) many times over (up to 30 litres or more). This is replaced continuously with donated or recycled blood and clotting factors to keep the patient alive, but frequent blood testing is essential. This is to identify what treatments are needed to maintain normal function of the heart, lungs, kidneys and other organs, and normal blood clotting. Blood samples are taken from special tubes or 'lines' routinely placed in blood vessels while the patient is asleep before surgery begins. When bleeding occurs during surgery special clotting factors and drugs can be given to improve clotting and help reduce bleeding, but these can have harmful effects, so the types and doses need to be guided by the results of clotting tests. Routine blood sampling during these procedures consists of 15 ml (3 tsp) taken every 60 minutes 5-10 times during the operation. In this study, an extra 6 ml (1.2 tsp) will be taken at the same times and from the same lines as these standard samples, allowing us to study the clotting measurements in the new Quantra device and compare these to similar measurements in another theatre-based device already in routine use, as well as to standard clotting tests done in the laboratory. At times of sampling the operating surgeon will also give a score indicating the state of blood clotting from visual assessment of the internal surfaces exposed by the surgery. The two devices' measurements of clotting, laboratory tests and the visual score given by the surgeon will be compared to assess the best indicator of the severity of the bleeding and response to treatment. The patient will not be managed differently from normal routine in any way apart from the small additional amounts of blood (maximum of 15-60 ml, or 3 -12 tsp) needed for Quantra measurements. No treatments will be based on these measurements. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04274699
Study type Observational
Source Cambridge University Hospitals NHS Foundation Trust
Contact
Status Withdrawn
Phase
Start date October 2020
Completion date October 2021

See also
  Status Clinical Trial Phase
Completed NCT04180735 - Intestinal Perforation in Patients Receiving an Orthtopic Liver Transplantation in the Montpellier University Hospital
Completed NCT01011205 - Phase 3b Study to Evaluate Advagraf in Combination With Mycophenolate Mofetil and Basiliximab in Liver Transplantation Phase 3
Completed NCT01888432 - Efficacy and Safety of Everolimus in Liver Transplant Recipients of Living Donor Liver Transplants Phase 3
Recruiting NCT04203004 - HOPE With Cytokine Filtration in Liver Transplantation (Cyto-HOPE) N/A
Recruiting NCT04564313 - Safety and Efficacy of Camrelizumab (Anti-PD-1 Antibody) in Recurrent HCC After Liver Transplantation Phase 1
Withdrawn NCT03596970 - Study of the Effect of Everolimus Immunosuppressive Combination Therapies on Renal Function When Used as a Maintenance Treatment for Liver Transplant Patients. Phase 3
Not yet recruiting NCT02544906 - Propofol Versus Dexmedetomidine for Prevention of Sevoflurane Agitation in Recipients of Living Donor Liver Transplantation N/A
Completed NCT03133065 - Early Treatment of Recurrent HCV- Infection Post Liver Transplantation in the Era of DAAs Phase 4
Recruiting NCT01705015 - Organ Transplantation Rehabilitation: Effect of Bedside Exercise Device and Activity Reinforcement N/A
Completed NCT01655563 - Pharmacogenetic Trial of Tacrolimus After Pediatric Transplantation Phase 2
Terminated NCT01445236 - Pilot Study of Immunosuppression Drug Weaning in Liver Recipients Exhibiting Biomarkers of High Likelihood of Tolerance N/A
Completed NCT01425385 - Autoregulation Assessment During Liver Transplantation N/A
Completed NCT00938860 - Sustained Virological Response (SVR) to Antiviral Treatment of Liver Transplant Recipients With Recurrent Hepatitis C Phase 4
Completed NCT00531921 - Effects of Donor and Recipient Genetic Expression on Heart, Lung, Liver, or Kidney Transplant Survival N/A
Withdrawn NCT00585429 - Evaluation of Kidney Disease in Liver Transplant Recipients N/A
Terminated NCT00585858 - Cytokine Kinetics Test to Assess the Presence or Absence of Tolerance in Organ Transplant N/A
Completed NCT00456235 - Reduction in the Risk of Rejection by Mycophenolate Mofetil Dose Adjustment in Liver Transplant Patients With Side Effects Caused by the Calcineurine Inhibitors Phase 4
Recruiting NCT00147459 - Immunogenicity of Booster Hepatitis B Vaccines in Children After Liver Transplantation N/A
Terminated NCT00161356 - Ambisome in Liver Transplant Patients Phase 4
Withdrawn NCT00167492 - Enteric Coated Myfortic for Liver Transplant Recipients Phase 4