Ischemic Heart Disease Clinical Trial
Official title:
Chronic Total Occlusion Percutaneous Coronary Intervention CTO-PCI Study
The objective of this study is to evaluate angiographic confirmation of placement of any guidewire beyond the CTO, in the true vessel lumen, in patients undergoing CTO percutaneous coronary intervention (PCI) in which at least one Teleflex guidewire and at least one Turnpike catheter are used.
A prospective, multicenter, single-arm, intent-to-treat, literature-controlled clinical study. The study will be conducted in up to 15 investigational sites in the U.S. This study will enroll up to 150 patients to provide adequate powering for hypothesis testing and an evaluable sample size of at least 135 patients. The population for this study is participants with signs and/or symptoms considered typical of ischemic heart disease attributed to a de novo CTO in a native coronary artery who are suitable candidates for a percutaneous revascularization. Study devices include the GuideLiner® V3 catheter, TrapLiner® catheter, Turnpike® catheter, and a series of five coronary guidewires (SpectreTM guidewire, R350TM guidewire, RaiderTM guidewire, WarriorTM guidewire, and BanditTM guidewire). All study devices are currently 510(k) cleared for non-CTO indications. - GuideLiner catheters are intended to be used in conjunction with guide catheters to access discrete regions of the coronary and/or peripheral vasculature, to facilitate placement of interventional devices, and to assist in crossing de novo chronic total occlusions (CTO). - The TrapLiner catheter is intended for use in conjunction with guide catheters to access discrete regions of the coronary and/or peripheral vasculature, to facilitate placement of interventional devices, to facilitate the exchange of an interventional device while maintaining the position of a guidewire within the vasculature, and to assist in crossing de novo chronic total occlusions (CTO). - The Turnpike catheters are intended to be used to access discrete regions of the coronary and/or peripheral vasculature. They may be used to facilitate placement and exchange of guidewires, to subselectively infuse/deliver diagnostic and therapeutic agents, and to assist in crossing de novo coronary chronic total occlusions (CTO). The Teleflex guidewires are intended for use in percutaneous procedures to introduce and position catheters and other interventional devices within the coronary and peripheral vasculature, including use in crossing or assisting in crossing de novo coronary chronic total occlusions (CTO). ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT05654272 -
Development of CIRC Technologies
|
||
Recruiting |
NCT06002932 -
Comparison of PROVISIONal 1-stent Strategy With DEB Versus Planned 2-stent Strategy in Coronary Bifurcation Lesions.
|
N/A | |
Active, not recruiting |
NCT04562805 -
Infinity-Swedeheart Registry Based Randomized Clinical Trial (R-RCT)
|
N/A | |
Recruiting |
NCT05292079 -
CAPTURER PMCF Study ( rEPIC04D )
|
||
Recruiting |
NCT05292092 -
Essential Pro PMCF Study ( rEPIC04E )
|
||
Recruiting |
NCT05292014 -
ANGIOLITE PMCF Study ( rEPIC04F )
|
||
Recruiting |
NCT05292118 -
Navitian PMCF Study ( rEPIC04C )
|
||
Completed |
NCT05292105 -
NC Xperience PMCF Study( rEPIC04B)
|
||
Completed |
NCT03076801 -
Does Choral Singing Help imprOve Stress in Patients With Ischemic HeaRt Disease?
|
N/A | |
Not yet recruiting |
NCT04153383 -
Milrinone on Cardiac Performance During Off-pump Coronary Artery Bypass Surgery
|
||
Recruiting |
NCT02982434 -
The New Pharmaceutical Composition Containing Botulinum Toxin to Treat Atrial Fibrillation
|
Phase 2 | |
Recruiting |
NCT02729064 -
Intraoperative Nasal Insulin Effect on Plasma and CSF Insulin Concentration and Blood Glucose
|
Phase 1 | |
Completed |
NCT02468401 -
Prevention of Contrast Induced Nephropathy in Patients With Advanced Renal Dysfunction Undergoing Coronary Interventions
|
N/A | |
Completed |
NCT02759406 -
Evaluation of the Palmaz Mach-5 Grooved Bare Metal Coronary Stent System Versus the Palmaz Bare Metal Coronary Stent System in Patients With Symptomatic Ischemic Heart Disease: A Safety and Performance Study
|
N/A | |
Recruiting |
NCT01681381 -
Evaluate Safety And Effectiveness Of The Tivoli® DES and The Firebird2® DES For Treatment Coronary Revascularization
|
N/A | |
Completed |
NCT01699802 -
Influence of Inhaled Anaesthetics on Rebreathing of Carbon Dioxide When Using an Anaesthesia Gas Reflector (AnaConDa)
|
N/A | |
Completed |
NCT01604213 -
Effects of Vildagliptin/Metformin Combination on Markers of Atherosclerosis, Thrombosis, and Inflammation in Diabetics With Coronary Artery Disease
|
Phase 4 | |
Completed |
NCT01724567 -
Copenhagen Study of Obese Patients With Ischemic Heart Disease Undergoing Low Energy Diet or Interval Training
|
N/A | |
Completed |
NCT01334268 -
RESOLUTE China RCT
|
N/A | |
Completed |
NCT02159235 -
Heavy Metals, Angiogenesis Factors and Osteopontin in Coronary Artery Disease (CAD)
|
N/A |