Outcome
Type |
Measure |
Description |
Time frame |
Safety issue |
Primary |
The change of EMG onset of multifidus, |
investigators will collect the EMG activity of multifidus using bipolar Ag-AgCl disposable surface electrodes (Better signal solution medical supply Co., limited, Zhongshan, China) and eight channels high-resolution wireless bio amplifier (WBA) system (Biomation, Almonte, Canada). |
baseline and six weeks |
|
Primary |
The change of EMG duration of multifidus, |
investigators will collect the EMG activity of multifidus using bipolar Ag-AgCl disposable surface electrodes (Better signal solution medical supply Co., limited, Zhongshan, China) and eight channels high-resolution wireless bio amplifier (WBA) system (Biomation, Almonte, Canada). |
baseline and six weeks |
|
Primary |
The change of EMG onset of transversus abdominus (TrA) muscle |
investigators will collect the EMG activity of TrA using bipolar Ag-AgCl disposable surface electrodes (Better signal solution medical supply Co., limited, Zhongshan, China) and eight channels high-resolution wireless bio amplifier (WBA) system (Biomation, Almonte, Canada). |
baseline and six weeks |
|
Primary |
The change of EMG duration of transversus abdominus (TrA) muscle |
investigators will collect the EMG activity of TrA using bipolar Ag-AgCl disposable surface electrodes (Better signal solution medical supply Co., limited, Zhongshan, China) and eight channels high-resolution wireless bio amplifier (WBA) system (Biomation, Almonte, Canada). |
baseline and six weeks |
|
Primary |
The change of EMG onset of gluteus medius (GM) muscle |
investigators will collect the EMG activity of GM using bipolar Ag-AgCl disposable surface electrodes (Better signal solution medical supply Co., limited, Zhongshan, China) and eight channels high-resolution wireless bio amplifier (WBA) system (Biomation, Almonte, Canada). |
baseline and six weeks |
|
Primary |
The change of EMG duration of gluteus medius (GM) muscle |
investigators will collect the EMG activity of GM using bipolar Ag-AgCl disposable surface electrodes (Better signal solution medical supply Co., limited, Zhongshan, China) and eight channels high-resolution wireless bio amplifier (WBA) system (Biomation, Almonte, Canada). |
baseline and six weeks |
|
Primary |
The change of EMG onset of vastus medialis obliqus (VMO) muscle |
investigators will collect the EMG activity of VMO using bipolar Ag-AgCl disposable surface electrodes (Better signal solution medical supply Co., limited, Zhongshan, China) and eight channels high-resolution wireless bio amplifier (WBA) system (Biomation, Almonte, Canada). |
baseline and six weeks |
|
Primary |
The change of EMG duration of vastus medialis obliqus (VMO) muscle |
investigators will collect the EMG activity of VMO using bipolar Ag-AgCl disposable surface electrodes (Better signal solution medical supply Co., limited, Zhongshan, China) and eight channels high-resolution wireless bio amplifier (WBA) system (Biomation, Almonte, Canada). |
baseline and six weeks |
|
Primary |
The change of EMG onset of vastus lateralis (VL) muscle |
investigators will collect the EMG activity of VL using bipolar Ag-AgCl disposable surface electrodes (Better signal solution medical supply Co., limited, Zhongshan, China) and eight channels high-resolution wireless bio amplifier (WBA) system (Biomation, Almonte, Canada). |
baseline and six weeks |
|
Primary |
The change of EMG duration of vastus lateralis (VL) muscle |
investigators will collect the EMG activity of VL using bipolar Ag-AgCl disposable surface electrodes (Better signal solution medical supply Co., limited, Zhongshan, China) and eight channels high-resolution wireless bio amplifier (WBA) system (Biomation, Almonte, Canada). |
baseline and six weeks |
|
Secondary |
pain intensity |
The eleven-point numerical rating scale will be used to measure pain severity for patients.where the endpoints are the extremes of no pain and pain as bad as it could be or worst pain. increasing the value means more intense pain. |
baseline and six weeks |
|
Secondary |
performance of functional activities |
kujala scale will be used to evaluate the performance of functional activities. This questionnaire includes 13 questions and the scores range from 0 to 100, where 100 indicates the highest efficiency of the knee and 0 indicates the highest disability. |
baseline and six weeks |
|