During general anesthesia, temperature monitoring is critical especially in pediatrics. Recently developed 3M™ Bair Hugger™ skin temperature which is applied on temporal artery is correlated with core temperature measure by esophageal prove in several studies. Conventional skin temperature over carotid artery is also correlated with core temperature in several studies. The purpose of this study is comparing 2 methods of temperature monitoring in pediatrics. First, conventional core temperature measure by esophageal stethoscope. Second, 3M™ Bair Hugger™ applying on carotid artery.


Clinical Trial Description

Core temperature should be monitored under general anesthesia. Because patients are prone to hypothermia during surgery, besides, pediatric patients are more vulnerable in temperature control. Conventional core temperature is monitored at esophagus, rectum, nasopharynx. But some of them are invasive and impossible in sometimes. Recently developed 3M™ Bair Hugger™ skin temperature which is applied on temporal artery is correlated with core temperature measured by esophageal prove in several studies. Its mechanism is making zero heat flux on skin applied. But it also cannot apply in head or facial surgery. Other studies showed conventional skin temperature over carotid artery is also correlated with core temperature. The investigators hypothesized using 3M™ Bair Hugger™ on carotid artery could be alternative method measuring core temperature. The purpose of this study is comparing 2 methods of temperature monitoring in pediatrics. First, conventional core temperature measure by esophageal stethoscope. Second, 3M™ Bair Hugger™ applying on carotid artery. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04057612
Study type Observational
Source Ajou University School of Medicine
Contact
Status Completed
Phase
Start date September 1, 2019
Completion date September 29, 2022

See also
  Status Clinical Trial Phase
Active, not recruiting NCT04279054 - Decreased Neuraxial Morphine After Cesarean Delivery Early Phase 1
Active, not recruiting NCT04580030 - Tricuapid Annular Plane Sistolic Excursion Before General Anesthesia Can Predict Hypotension After Induction
Completed NCT03640442 - Modified Ramped Position for Intubation of Obese Females. N/A
Recruiting NCT04099693 - A Prospective Randomized Study of General Anesthesia Versus Anesthetist Administered Sedation for ERCP
Terminated NCT02481999 - Pre- and Postoperative EEG-Monitoring for Children Aged From 0,5 to 8 Years
Completed NCT04235894 - An Observer Rating Scale of Facial Expression Can Predict Dreaming in Propofol Anesthesia
Recruiting NCT05525104 - The Effect of DSA on Recovery of Anaesthesia in Children (Het Effect Van DSA op Het Herstel na Anesthesie Bij Kinderen). N/A
Recruiting NCT05024084 - Desflurane and Sevoflurane Minimal Flow Anesthesia on Recovery and Anesthetic Depth Phase 4
Completed NCT04204785 - Noise in the OR at Induction: Patient and Anesthesiologists Perceptions N/A
Completed NCT03277872 - NoL, HR and MABP Responses to Tracheal Intubation Performed With MAC Blade Versus Glidescope N/A
Terminated NCT03940651 - Cardiac and Renal Biomarkers in Arthroplasty Surgery Phase 4
Terminated NCT02529696 - Measuring Sedation in the Intensive Care Unit Using Wireless Accelerometers
Completed NCT05346588 - THRIVE Feasibility Trial Phase 3
Terminated NCT03704285 - Development of pk/pd Model of Propofol in Patients With Severe Burns
Recruiting NCT05259787 - EP Intravenous Anesthesia in Hysteroscopy Phase 4
Completed NCT02894996 - Does the Response to a Mini-fluid Challenge of 3ml/kg in 2 Minutes Predict Fluid Responsiveness for Pediatric Patient? N/A
Completed NCT05386082 - Anesthesia Core Quality Metrics Consensus Delphi Study
Terminated NCT03567928 - Laryngeal Mask in Upper Gastrointestinal Procedures N/A
Recruiting NCT06074471 - Motor Sparing Supraclavicular Block N/A
Completed NCT04163848 - CARbon Impact of aNesthesic Gas