Cataracts Clinical Trial
Official title:
Clinical Investigation of AcrySof® IQ ReSTOR® Multifocal Toric Intraocular Lens Models SND1T3/ SND1T4/ SND1T5/ SND1T6
NCT number | NCT01424189 |
Other study ID # | C-09-036 |
Secondary ID | |
Status | Completed |
Phase | N/A |
First received | |
Last updated | |
Start date | July 2011 |
Est. completion date | January 2013 |
Verified date | May 2018 |
Source | Alcon Research |
Contact | n/a |
Is FDA regulated | No |
Health authority | |
Study type | Interventional |
The purpose of this study is to evaluate the safety and effectiveness of an investigational multifocal toric intraocular lens (IOL) compared to an FDA-approved multifocal IOL.
Status | Completed |
Enrollment | 677 |
Est. completion date | January 2013 |
Est. primary completion date | January 2013 |
Accepts healthy volunteers | No |
Gender | All |
Age group | 21 Years and older |
Eligibility |
Inclusion Criteria: - Diagnosed with bilateral cataracts; - Able to comprehend and sign a statement of informed consent; - Calculated lens power and astigmatism within the available range; - Willing and able to complete all required postoperative visits; - Planned cataract removal by phacoemulsification; - Potential postoperative visual acuity of 0.2 logMAR or better in both eyes; - Preoperative astigmatism in both operative eyes as described in the clinical protocol; Note: Corneal incisions made to reduce astigmatism will not be allowed during the course of the study. - Clear intraocular media other than cataract in study eyes; - Preoperative Best Corrected Distance Visual Acuity (BCDVA) worse than 0.2 logMAR in each eye; - Pupil size greater than or equal to 6 mm after dilation; - Able to undergo second eye surgery within 30 days of the first eye surgery; - Other protocol-specified inclusion criteria may apply. Exclusion Criteria: - Significant irregular corneal aberration as demonstrated by corneal topography; - Keratopathy/Kerectasia - any corneal abnormality, other than regular corneal astigmatism; - Any inflammation or edema (swelling) of the cornea; - Diagnosed degenerative visual disorders (e.g. macular degeneration or other retinal disorders) that are predicted (by subjective assessment of the retina) to cause future acuity losses to a level worse than 0.2 logMAR; - Reasonably expected to require a secondary surgical intervention at any time during the study (other than YAG capsulotomy); - Previous corneal refractive surgery; - Amblyopia; - Clinically severe corneal dystrophy (e.g., epithelial, stromal, or endothelial dystrophy); - Diabetic retinopathy; - Extremely shallow anterior chamber, not due to swollen cataract; - Microphthalmos; - Previous retinal detachment; - Previous corneal transplant; - Recurrent severe anterior or posterior segment inflammation of unknown etiology; - Rubella or traumatic cataract; - Iris neovascularization; - Glaucoma (uncontrolled or controlled with medication); - Aniridia; - Optic nerve atrophy; - Pregnancy; - Current participation in another investigational drug or device study that may confound the results of this investigation; - Other planned ocular surgery procedures, including, but not limited to LASIK, astigmatic keratotomy and limbal relaxing incisions, for the duration of the study; - Other protocol-specified exclusion criteria may apply. |
Country | Name | City | State |
---|---|---|---|
n/a |
Lead Sponsor | Collaborator |
---|---|
Alcon Research |
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | Mean Monocular Uncorrected Distance Visual Acuity (UCDVA) at Fixed Distance at Visit 5 | Visual acuity (VA) was measured monocularly (each eye separately) without visual correction using a 100% contrast ETDRS (Early Treatment of Diabetic Retinopathy Study) chart positioned 4 meters (m) from the participant under well-lit conditions. +0.25 diopter (D) spherical power was applied to correct for optical infinity. VA was measured in logMAR (logarithm of the minimum angle of resolution), with 0.1 logMAR increment corresponding to 5 letters, or 1 line, on an ETDRS chart. A lower numeric value represents better visual acuity. This analysis was prespecified for the first operative eye. | Month 12 from second eye implantation | |
Primary | Mean Monocular Uncorrected Near Visual Acuity (UCNVA) at Fixed Distance at Visit 5 | VA was measured monocularly without visual correction using a hand-held ETDRS chart at a fixed distance that differed by lens model implanted. The logMAR ETDRS near visual acuity chart was designed for use at 40 cm; results obtained at other distances were converted to reflect the change in apparent letter size that results from the change in distance. VA was measured in logMAR, with 0.1 logMAR increment corresponding to 5 letters, or 1 line, on an ETDRS chart. A lower numeric value represents better visual acuity. This analysis was prespecified for the first operative eye. | Month 12 from second eye implantation | |
Primary | Rate of Actual and Potential Secondary Surgical Interventions (SSIs) Related to the Optical Properties of the IOL for First and Second Operative Eyes Separately at Visit 5 | The rate of actual and potential secondary surgical interventions (SSIs) related to the optical properties of the IOL was estimated. If an ocular surgical intervention was performed, it qualified as an actual SSI; however; if the participant met the protocol-specified criteria that would warrant an SSI, but didn't actually undergo the SSI, it qualified as a potential SSI. Rate is presented as percentage of participants. | Month 12 from second eye implantation | |
Secondary | Rate of Severe Visual Disturbances/Distortions Reported on the Assessment of Photic Phenomena & Lens EffectS (APPLES) Questionnaire at Visit 5 | Visual disturbances/distortions were reported by the participant on the Assessment of Photic Phenomena and Lens EffectS (APPLES) questionnaire, a Patient Reported Outcome (PRO) questionnaire intended to evaluate 10 distinct visual phenomena associated with cataract extraction and IOL implantation. The first 20 questions addressed both the frequency and severity of the phenomena using a 4-point categorical scale ranging from "never" to "always" (frequency) or "none" to "severe" (severity). The final (21st) question indicated whether the participant answered the questions based on experiences with or without glasses. The participant completed the assessment as a retrospective analysis of the previous week. Rate is presented as the percentage of participants with severity score "severe" for the visual phenomenon. | Month 12 from second eye implantation |
Status | Clinical Trial | Phase | |
---|---|---|---|
Active, not recruiting |
NCT06005675 -
User Acceptability Evaluation of Pseudophakic Patients Previously Implanted With the TECNIS Odyssey IOL
|
||
Active, not recruiting |
NCT01382641 -
Show Improved Vision With the HOYA AF-1 Aspheric Intraocular Lens After Cataract Surgery
|
Phase 4 | |
Completed |
NCT01382823 -
Laser Cataract Surgery With the Femtosecond Laser Technology
|
Phase 4 | |
Completed |
NCT05991960 -
Evaluation of Real-World Data on the Performance of the TECNIS Odyssey™ IOL
|
||
Active, not recruiting |
NCT05574959 -
Clinical Investigation of the TECNIS® Next-Generation Intraocular Lens, Model DEN00V
|
N/A | |
Completed |
NCT02492659 -
Clinical Research of Femtosecond Laser-Assisted Cataract Surgery
|
N/A | |
Completed |
NCT01279031 -
Randomized Comparison of the Abbott WHITESTAR Signature System With Ellips Tranversal Ultrasound vs. the Alcon Infiniti With the Ozil Torsional Handpiece in Phacoemulsification: A Contralaterally-Controlled Trial
|
Phase 4 | |
Completed |
NCT01001806 -
A Comparison of Peak Aqueous Penetration of Acuvail (Ketorolac 0.45%), Xibrom (Bromfenac 0.09%), and Nevanac (Nepafenac 0.1%)in Patients Undergoing Phacoemulsification
|
Phase 4 | |
Completed |
NCT01061463 -
Occupational Cataracts and Lens Opacities in Interventional Cardiology : the O'CLOC Study
|
N/A | |
Completed |
NCT01021761 -
A Comparison of Prostaglandin E2 (PGE2) Inhibition of Acuvail(Ketorolac 0.45%), Xibrom (Bromfenac 0.09%)and Nevanac (Nepafenac)in Patients Undergoing Phacoemulsification
|
Phase 4 | |
Completed |
NCT00999492 -
Selection of Aspheric Diffractive Multifocal Intraocular Lens (IOLS) Based on Corneal Wavefront
|
Phase 4 | |
Completed |
NCT00542581 -
Acrysof Toric SN60T3corneal Astigmatism Between 0.75 and 1.00 D.
|
N/A | |
Completed |
NCT03708367 -
A Post-Market Evaluation of LipiFlow Treatment in Cataract Surgery Practice
|
N/A | |
Completed |
NCT05575063 -
Clinical Investigation of Healon EndoCoat Ophthalmic Viscosurgical Device (OVD)
|
N/A | |
Recruiting |
NCT05531292 -
PROOF-OF-CONCEPT STUDY FOR NEW INTRAOCULAR LENS, MODEL C0002
|
N/A | |
Completed |
NCT05058274 -
Clinical Results of a Monofocal Aspheric Bitoric Intraocular Lens With Plate Haptics in Hyperopic Eyes (HIPER-AT-TORBI)
|
||
Completed |
NCT05053399 -
Evaluation of the TECNIS Symfony® Toric Intraocular Lens
|
N/A | |
Recruiting |
NCT02639845 -
Eye Drop Application Monitor, Pilot Study
|
N/A | |
Completed |
NCT01684007 -
A Clinical Outcome Study of Two Multifocal Intraocular Lenses (IOL) in Cataract Patients
|
N/A | |
Completed |
NCT00827073 -
Comparison of Tetracaine 0.5% and Lidocaine 2% Jelly for Topical Phacoemulsification Cataract Surgery
|
N/A |