Cataracts Clinical Trial
Official title:
Evaluation of the Efficacy of a Surface Modified Intraocular Lens in Reducing Post-Operative Inflammatory Signs Following Extracapsular Surgery in Uveitis Patients With Cataracts
This study will test the effectiveness of an intraocular lens treated with heparin in
reducing or preventing inflammation after cataract surgery in patients with uveitis.
Patients with uveitis (inflammatory eye disease) often develop cataracts (clouding of the
lens of the eye) that can impair eyesight. Cataracts can be removed surgically, and this is
usually done when poor vision interferes with adequate daily functioning, or when the lens
becomes too cloudy to evaluate the level of eye inflammation in uveitis-information needed
to adjust medication dosages. After surgery, vision is corrected with special eyeglasses,
contact lenses, or intraocular lenses (IOL). IOLs are small, plastic artificial lenses
permanently placed inside the eye.
Patients with uveitis who require cataract surgery and whose eye inflammation has been
controlled by medicine for at least 3 months may be eligible for this study. Those enrolled
in the study will be randomly assigned to one of two treatment groups: one group will have a
standard IOL implanted during cataract surgery; the other will receive a heparin-treated
IOL.
Before surgery, patients will undergo standard preoperative tests, including chest X-ray,
electrocardiogram, blood tests and urinalysis, as well as an eye examination that includes
photography of the cornea, iris and retina. Additional tests and examinations to be done at
the start of the study and at periodic follow-up visits for about 1 year may include:
fluorescein angiography to evaluate the blood vessels of the retina; specular microscopy to
examine the surface of the IOL; cell and flare measurements to evaluate inflammation, and
ultrasound to examine the back of the eye.
The purpose of this project is to evaluate the ability of a heparin-surface modified intraocular lens to reduce the incidence and severity of post-operative inflammation in patients with uveitis undergoing extracapsular cataract surgery. Patients who have a history of uveitis and have been in remission on steroids and/or cyclosporine or cytotoxic agents for at least three months will be considered for this study. They will be randomized in a masked fashion to either a surface-modified lens or to a non-modified lens of similar design. The intraocular inflammation will be assessed using standardized clinical criteria, and by a laser cell flare meter at those sites using this equipment. The presence of inflammatory cells on the lens surface will be assessed using specular micrography. In an initial period, the study will only be carried out in the Clinical Center of the National Eye Institute (NEI) at the National Institutes of Health (NIH). However, in order to complete the study in a reasonable period of time, it may be expanded to include several outside centers. ;
Endpoint Classification: Safety/Efficacy Study, Primary Purpose: Treatment
Status | Clinical Trial | Phase | |
---|---|---|---|
Active, not recruiting |
NCT06005675 -
User Acceptability Evaluation of Pseudophakic Patients Previously Implanted With the TECNIS Odyssey IOL
|
||
Active, not recruiting |
NCT01382641 -
Show Improved Vision With the HOYA AF-1 Aspheric Intraocular Lens After Cataract Surgery
|
Phase 4 | |
Completed |
NCT01382823 -
Laser Cataract Surgery With the Femtosecond Laser Technology
|
Phase 4 | |
Completed |
NCT05991960 -
Evaluation of Real-World Data on the Performance of the TECNIS Odyssey™ IOL
|
||
Active, not recruiting |
NCT05574959 -
Clinical Investigation of the TECNIS® Next-Generation Intraocular Lens, Model DEN00V
|
N/A | |
Completed |
NCT02492659 -
Clinical Research of Femtosecond Laser-Assisted Cataract Surgery
|
N/A | |
Completed |
NCT01279031 -
Randomized Comparison of the Abbott WHITESTAR Signature System With Ellips Tranversal Ultrasound vs. the Alcon Infiniti With the Ozil Torsional Handpiece in Phacoemulsification: A Contralaterally-Controlled Trial
|
Phase 4 | |
Completed |
NCT01061463 -
Occupational Cataracts and Lens Opacities in Interventional Cardiology : the O'CLOC Study
|
N/A | |
Completed |
NCT01021761 -
A Comparison of Prostaglandin E2 (PGE2) Inhibition of Acuvail(Ketorolac 0.45%), Xibrom (Bromfenac 0.09%)and Nevanac (Nepafenac)in Patients Undergoing Phacoemulsification
|
Phase 4 | |
Completed |
NCT00999492 -
Selection of Aspheric Diffractive Multifocal Intraocular Lens (IOLS) Based on Corneal Wavefront
|
Phase 4 | |
Completed |
NCT01001806 -
A Comparison of Peak Aqueous Penetration of Acuvail (Ketorolac 0.45%), Xibrom (Bromfenac 0.09%), and Nevanac (Nepafenac 0.1%)in Patients Undergoing Phacoemulsification
|
Phase 4 | |
Completed |
NCT00542581 -
Acrysof Toric SN60T3corneal Astigmatism Between 0.75 and 1.00 D.
|
N/A | |
Completed |
NCT03708367 -
A Post-Market Evaluation of LipiFlow Treatment in Cataract Surgery Practice
|
N/A | |
Completed |
NCT05575063 -
Clinical Investigation of Healon EndoCoat Ophthalmic Viscosurgical Device (OVD)
|
N/A | |
Recruiting |
NCT05531292 -
PROOF-OF-CONCEPT STUDY FOR NEW INTRAOCULAR LENS, MODEL C0002
|
N/A | |
Completed |
NCT05058274 -
Clinical Results of a Monofocal Aspheric Bitoric Intraocular Lens With Plate Haptics in Hyperopic Eyes (HIPER-AT-TORBI)
|
||
Completed |
NCT05053399 -
Evaluation of the TECNIS Symfony® Toric Intraocular Lens
|
N/A | |
Recruiting |
NCT02639845 -
Eye Drop Application Monitor, Pilot Study
|
N/A | |
Completed |
NCT01684007 -
A Clinical Outcome Study of Two Multifocal Intraocular Lenses (IOL) in Cataract Patients
|
N/A | |
Completed |
NCT00827073 -
Comparison of Tetracaine 0.5% and Lidocaine 2% Jelly for Topical Phacoemulsification Cataract Surgery
|
N/A |