Rationale: Diligent fluid management is instrumental to improve postoperative outcome, cost and quality of care. Objective: To determine the accuracy of brachial, femoral and carotid blood flow measurement with ultrasound compared to intermittent transpulmonary thermodilution cardiac output measurement, invasive and non-invasive pulse-contour analysis. Study design: Observational study - Prospective clinical non-intervention measurement study. Study population: Adult ASA 1-2 patients, scheduled for open upper GI surgery Intervention (if applicable): Not applicable. We will perform non-invasive ultrasound measurements of the femoral, carotid and brachial blood flow right before induction and under anaesthesia. Main study parameters/endpoints: Femoral, carotid and brachial blood flow determined by ultrasound and blood flow variation and the accuracy compared to transpulmonary thermodilution cardiac output, stroke volume variation, and pulse-contour analysis derived cardiac output (invasive or non-invasive) at the following time points during surgery; (limited for femoral site as it cannot be measured during surgery): (1) before induction of anaesthesia, (2) after induction, (3) 15 minutes after start of surgery, (4) before and (5) after (1-2 minutes) a fluid bolus, (6) before and (7) after start of vasopressors, (8) before and (9) after Trendelenburg position and (10) after surgery before end of anaesthesia (figure 1). A fluid bolus will be performed as part of standard care (goal-directed fluid therapy). The vasopressor and Trendelenburg position time points are optional measurements. We will also measure (continuous) invasive femoral blood pressure (SBP, DBP, MAP), non-invasive blood pressure, SVV, central venous pressure (when available), heart rate, SpO2, PFI, etCO2.


Clinical Trial Description

n/a


Study Design


Related Conditions & MeSH terms


NCT number NCT04593797
Study type Observational
Source Academisch Medisch Centrum - Universiteit van Amsterdam (AMC-UvA)
Contact
Status Completed
Phase
Start date April 19, 2018
Completion date January 9, 2019

See also
  Status Clinical Trial Phase
Completed NCT05070819 - Atrial Natriuretic Peptide in Assessing Fluid Status N/A
Recruiting NCT05492968 - The Effect of Epinephrine, Norepinephrine and Phenylephrine on Intraoperative Hemodynamic Performance Phase 4
Completed NCT03444545 - Continous Cardiac Output - Non-Invasive Evaluation (CONNIE)
Recruiting NCT04064177 - Non-invasive Continuous Cardiac Output Monitoring in Preterm Infants Study
Withdrawn NCT03058653 - Use of a Mini-fluid Bolus to Identify Fluid Responsiveness N/A
Completed NCT02880683 - Cardiac Output Autonomic Stimulation Therapy for Heart Failure (COAST-HF) - Human NeuroCatheter Study N/A
Recruiting NCT00989508 - Myocardial Protection With Perhexiline in Left Ventricular Hypertrophy Phase 2/Phase 3
Completed NCT04955184 - Comparing Cardiac Output Measurements Using a Wearable, Wireless, Non-invasive PPG-Based Device to a Swan Ganz Catheter
Completed NCT02964663 - Comparison of the Ability of the esCCO and the Volume View to Measure Trends in Cardiac Output During Cardiac Surgery N/A
Completed NCT04641949 - Methoxyflurane and Fentanyl in LBNP Phase 4
Recruiting NCT04191408 - Predictive Ability of PEEP Induced Changes in CVP to Predict Volume Responsiveness in Mechanically Ventilated Patients After Major Abdominal Surgery N/A
Completed NCT01892696 - Effects of Inspiratory Flow Waveforms on Preload N/A
Recruiting NCT02728791 - Comparison of Allows Measurement of Cardiac Output Between Clearsight System and Transpulmonary Thermodilution N/A
Completed NCT03930979 - The Effect of Hyperoxia on Cardiac Output
Recruiting NCT04755764 - Effect of Labetalol, Atenolol, and Nifedipine on Maternal Hemodynamics Measured by ICG in Early Pregnancy
Enrolling by invitation NCT02702544 - Effect of Passive Leg Raising for Fluid Responsiveness N/A
Completed NCT01880684 - Validation of Capnography as a Predictor of Cardiac Output Change as Measured by FloTrac Phase 2
Recruiting NCT05035719 - Comparison Studies Comparing Hemodynamic Parameters Provided by the Caretaker Against Respective Gold Standard References
Not yet recruiting NCT04774978 - Real-time Continuous Cardiac Output Measurements N/A
Completed NCT02485782 - Changes in Volumetric Hemodynamic Parameters Induced by Fluid Removal on Hemodialysis N/A