On the Intensive Care Unit doctors give a lot of fluid to patients in order to improve their blood pressure, amount of urine made or to let doctors stop drugs that are needed to keep blood pressure up. Doctors normally give patients 500ml of fluid over 25 minutes as standard, however it is very difficult to know if giving those fluids and how much fluid will help (it does in some but not others). If a person gets too much fluid this can also cause problems such as fluid in lungs, poor kidney function, or swelling in the limbs. The LidCo Rapid monitor lets the Intensive Care Unit (ICU) team know the amount of blood the heart pushes out with each beat (Stroke volume). It works by following the tracing off the arterial line (Blood pressure monitor) that has been inserted as part of the standard care of a patient on the ICU. It does not need any other invasive procedures or drug administration to work. This study is using this monitor to see if it can identify a method of improving the administration of intravenous fluids on the Intensive Care Unit. The study is looking to see if it can identify whether giving a small amount of fluid first identifies people who will benefit from more fluid and those that won't.


Clinical Trial Description

Adult patients whom the Consultant Intensivist decides should receive a fluid challenge as part of their standard care in order to improve haemodynamic parameters will be approached. Reasons for fluid administration include evidence of inadequate tissue perfusion such as raised blood lactate or poor urine output, hypotension or attempts to wean vasopressor dose. Patients will be identified as suitable for inclusion by the Consultant Responsible for the Intensive Care Unit on each day. As fluid responsiveness is a transient phenomenon which disappears after significant fluid resuscitation it is proposed that patients will be immediately entered into the study so that the study contains a mix of fluid responsive and non-responsive patients in order to get the time critical data required which may be lost if there is a significant delay before study entry. Informed consent will be sought from the patient, or if they are incapacitated by critical illness, their relative will be approached for assent as soon as possible and within 48 hours of study enrollment. This is in line with recommendations for Research involving emergency treatment. The LiDCOrapid machine will be connected in the same manner as the LiDCOplus machine, currently in use on ICU, in order to obtain the stroke volume measurement. A smartcard is inserted and the patient details entered. Monitoring will continue until fluids are clinically indicated. Patients will be given fluid boluses via either peripheral or central venous catheters. The following data will be collected for each patient: Age, Gender, Height, Weight, diagnosis requiring ICU admission, location of venous and arterial catheters, APACHE II scores, Cumulative fluid balance at time of bolus administration, Ventilation status (self-ventilating, non-invasive ventilation, invasive ventilation and mode if appropriate), tidal volume if measured, drugs being infused (sedatives, inotropes, vasoactive drugs, diuretics, muscle relaxants, etc), presence of renal replacement therapy. Fluid administration protocol: Patients will be monitored just prior to infusion for hemodynamic stability, Standard practice is to administer a bolus of 500ml given via an infusion pump at a rate of 1200mL/hour (25min). For study patients the first 250ml will be given in 50ml boluses using a 50ml syringe. Each bolus will be given over approximately 1 minute and the study measurements will be recorded followed by a wait for response of 1 minute. This will be repeated for each subsequent bolus until 250ml has been given (i.e. 5 boluses). The remaining 250ml will be given via the standard infusion pump method at a rate of 1000ml/hour which will complete in 15 minutes. In total, the 500ml will be given over 25 minutes. At the end of each bolus Stroke volume, cardiac output, heart rate, blood pressure will be determined. Up to 2 sets of data per patient per day will be collected. The majority of patients routinely stay in the ICU for 2 days, while in a smaller group, for much longer. A maximum of 4 data sets will be collected per patient. The fluid boluses will be administered at the discretion of the treating physician who believes that they will improve the clinical condition of the patient. The study team will have no influence on the timing of these. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT03058653
Study type Interventional
Source The Royal Wolverhampton Hospitals NHS Trust
Contact
Status Withdrawn
Phase N/A
Start date October 2021
Completion date October 2022

See also
  Status Clinical Trial Phase
Completed NCT05070819 - Atrial Natriuretic Peptide in Assessing Fluid Status N/A
Recruiting NCT05492968 - The Effect of Epinephrine, Norepinephrine and Phenylephrine on Intraoperative Hemodynamic Performance Phase 4
Completed NCT03444545 - Continous Cardiac Output - Non-Invasive Evaluation (CONNIE)
Recruiting NCT04064177 - Non-invasive Continuous Cardiac Output Monitoring in Preterm Infants Study
Completed NCT02880683 - Cardiac Output Autonomic Stimulation Therapy for Heart Failure (COAST-HF) - Human NeuroCatheter Study N/A
Recruiting NCT00989508 - Myocardial Protection With Perhexiline in Left Ventricular Hypertrophy Phase 2/Phase 3
Completed NCT04955184 - Comparing Cardiac Output Measurements Using a Wearable, Wireless, Non-invasive PPG-Based Device to a Swan Ganz Catheter
Completed NCT02964663 - Comparison of the Ability of the esCCO and the Volume View to Measure Trends in Cardiac Output During Cardiac Surgery N/A
Completed NCT04641949 - Methoxyflurane and Fentanyl in LBNP Phase 4
Recruiting NCT04191408 - Predictive Ability of PEEP Induced Changes in CVP to Predict Volume Responsiveness in Mechanically Ventilated Patients After Major Abdominal Surgery N/A
Completed NCT01892696 - Effects of Inspiratory Flow Waveforms on Preload N/A
Recruiting NCT02728791 - Comparison of Allows Measurement of Cardiac Output Between Clearsight System and Transpulmonary Thermodilution N/A
Completed NCT03930979 - The Effect of Hyperoxia on Cardiac Output
Recruiting NCT04755764 - Effect of Labetalol, Atenolol, and Nifedipine on Maternal Hemodynamics Measured by ICG in Early Pregnancy
Enrolling by invitation NCT02702544 - Effect of Passive Leg Raising for Fluid Responsiveness N/A
Completed NCT01880684 - Validation of Capnography as a Predictor of Cardiac Output Change as Measured by FloTrac Phase 2
Recruiting NCT05035719 - Comparison Studies Comparing Hemodynamic Parameters Provided by the Caretaker Against Respective Gold Standard References
Not yet recruiting NCT04774978 - Real-time Continuous Cardiac Output Measurements N/A
Completed NCT02485782 - Changes in Volumetric Hemodynamic Parameters Induced by Fluid Removal on Hemodialysis N/A
Completed NCT00446017 - The Effects of Adrenaline and Milrinone in Patients With Myocardial Dysfunction After CABG Phase 3