View clinical trials related to Cardiac Electrophysiology.
Filter by:Perioperative stress may increase the incidence of adverse events in the cardiovascular system and lead to poor prognosis. Dexmedetomidine is a highly selective α2 adrenergic receptor agonist, which can inhibit stress response and reduce hemodynamic fluctuations. In different usage plans, dexmedetomidine can have different effects on hemodynamics, myocardial electrical activity, cardiac function. The main purpose was to observe its effects on myocardial electrophysiology and cardiac function during perioperative period. The secondary purpose was to explore the optimal dose of dexmedetomidine that has the least adverse effects on perioperative electrocardia action and cardiac function
His-Ventricle (HV) measurement is only obtained invasively using transvenous catheters. This kind of procedure is routinely performed but some risks of complication exist. HV interval prolongation is correlated with increased risk of occurrence of complete atrioventricular block which could lead to syncope or cardiac sudden death. A new non invasive, high density and high fidelity system (BioSemi, BioSemi B.V., Amsterdam, Netherlands) can theorically collect such electrophysiological signal using a signal averaging acquisition method. We want to assess the possibility of non invasive HV interval measurement using this new device.
This prospective, multicenter, post-market clinical study was designed to evaluate the outcomes of lead extraction of cardiovascular implantable electronic devices (CIED) using Cook catheter and lead extraction devices for any indication it is used in the commercial setting within the United States and Europe. The purpose of this clinical study is to collect data on the performance of the Cook lead extraction devices for the purpose of supporting publications and presentations
Acute respiratory failure is frequent during rhythmology procedure under light sedation in high risks selected patients. Non invasive ventilation (NIV) is recommended for acute cardiogenic pulmonary oedema and sleep apnea. The investigators will perform a monocentric, prospective, randomized controlled trial to compare the efficacy of NIV which associated pressure support ventilation (PSV: 5 to 15 cmH2O) and positive end expiratory pressure (PEEP: 5 to 10 cmH2O) with standard oxygen therapy in prevention of peroperative respiratory event. Our hypothesis is that peroperative use of NIV should reduce the incidence of apnea and hypoxia during procedure in rhythmology under light sedation.