Clinical Trials Logo

Clinical Trial Summary

Transesophageal echocardiography (TEE) has become a standard monitoring tool during cardiac surgery. It allows continuous accurate assessment of heart structures and function without interfering with the surgery and the anesthetics. The imaging of cardiac structures is used to direct optimal surgical intervention and assess surgical results. Cardiac output (CO) is the result of stroke volume (SV) multiplied by the heart rate.

Measurement of cardiac output (CO) is used to quantify the performance of the left ventricle. It is commonly achieved using a pulmonary artery catheter (PAC) (also known ad Swann-Ganz catheter). A known amount of saline solution is injected in the proximal part of the catheter and the variation of blood temperature detected at the tip. Cardiac output is measured based on the duration and degree of temperature change. This method remains an accepted gold standard. TEE allows measurement of cardiac output using a number of different 2D and 3D imaging modalities. Although current guidelines identify the Method of the Disks(MOD) as the gold standard other technique could potentially be more precise. In this study, the investigators want to assess the accuracy of four different TEE methods to measure cardiac output compared with Thermodilution as a standard of care.


Clinical Trial Description

The measurement of the LV performance, as reflected by measuring cardiac output (CO), is an important component of hemodynamic assessment during cardiac (and non-cardiac) surgery. It has become standard of care in guiding fluid management and inotropic therapy in both the operating room (OR) and the intensive care unit (ICU) in most centres, and is considered by far the most understood and commonly communicated parameter of cardiac performance, in addition to being consistently shown as a predictor of patients' outcome.

Several methods have been used to measure CO. The most commonly used is via thermodilution (PAC), but its invasive nature and potential for serious complications led to the utilization of the non-invasive methods, such as those based on TEE.

Since the establishment of the role of TEE in the setting of hemodynamic monitoring during cardiac surgery, various ways of quantifying LV function have been utilized. The method recommended by current guidelines is a volumetric calculation via the method of disks (modified Simpson's method, MOD). Recent advances in ultrasound technology and software development allow the utilization three-dimensional (3D) volumetric assessment and speckle tracking for cardiac deformation. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT03349970
Study type Observational
Source University Health Network, Toronto
Contact
Status Active, not recruiting
Phase
Start date August 1, 2017
Completion date December 1, 2019

See also
  Status Clinical Trial Phase
Recruiting NCT05490303 - HeartGuide: Preliminary Study N/A
Completed NCT05070819 - Atrial Natriuretic Peptide in Assessing Fluid Status N/A
Not yet recruiting NCT04538469 - Absent Visitors: The Wider Implications of COVID-19 on Non-COVID Cardiothoracic ICU Patients, Relatives and Staff
Not yet recruiting NCT04511403 - Prevalence of Oral Mucosal Alterations In a Sample of Egyptian Patients With Cardiovascular Diseases: A Hospital- Based Cross-Sectional Study
Completed NCT02697760 - The CZT Dynamic Myocardial Perfusion Imaging
Terminated NCT05157568 - Pilot Randomized Clinical Trial of Live-streamed Cardiovascular Rehabilitation N/A
Not yet recruiting NCT04160845 - Non-invasive Forehead Skin Temperature in Cardiac Surgery
Completed NCT04500912 - Comparison of the Supraflex Cruz 60 Micron Versus the Ultimaster Tansei 80 Micron in HBR PCI Population N/A
Not yet recruiting NCT06438159 - Impact of Mindfulness-Based Stress Reduction Meditation Practice on Patients After Cardiac Rehabilitation. N/A
Recruiting NCT06154473 - Assessment of Patients Undergoing Cardiac Surgery and Admitted to the Intensive Care Unit
Not yet recruiting NCT05877755 - Validation of Multi-contrast, High-resolution Cardiac Magnetic Resonance Imaging N/A
Completed NCT03394859 - Electronic Medical Records and Genomics (eMERGE) Phase III
Recruiting NCT05055830 - Opportunistic PK/PD Trial in Critically Ill Children (OPTIC)
Recruiting NCT04374799 - Heparin vs Placebo for Cardiac Catheterization Phase 3
Completed NCT03174106 - Longterm Follow-up of Cardiac Patients With an Smartphone-Application N/A
Recruiting NCT05531253 - Respired Gases in Patients Post Cardiac Surgery
Recruiting NCT04609228 - Cardiac Surgery Outcomes in Blood-transfusion Acceptors and no Acceptors
Recruiting NCT06149143 - Cardiac Performance System Data Collection Study - Minnesota
Recruiting NCT05725655 - Hot Water Immersion After Myocardial Infarction N/A
Recruiting NCT06073509 - Atrial Fibrillation and Other Cardiac Arrhythmias and Diseases After Radiotherapy for Breast Cancer : Watch Your HeaRT