Personalization of CM Injection Protocols in Coronary Computed Tomographic Angiography
Cardiac computed tomography (CCT) is one of the standard non-invasive imaging techniques
allowing imaging of the heart and coronary arteries with a high temporal and spatial
resolution. The high sensitivity and negative predictive value (NPV) of coronary CT
angiography (CCTA) make it a valuable tool in the assessment of coronary artery disease (CAD)
in patients with low to intermediate risk for CAD, especially to rule out CAD. This risk
stratification can be done with help of multiple different risk-calculators (e.g. the updated
Diamond-Forrester model by Genders et al. 2012). These calculators take different variables
into account, e.g. advanced age, gender, blood pressure, diabetes mellitus (DM), lipid
profile and smoking.
The aim of CCTA is a high diagnostic accuracy, which depends on both optimal intravascular
enhancement (in Hounsfield Units; minimal 325 HU) and contrast-to-noise ratio (CNR). Optimal
intravascular enhancement and CNR depend on different factors such as scan technique (e.g.
tube voltage, tube potential), parameters of the administered contrast material (CM) and
patient related factors (e.g. cardiac output (CO), body weight (BW)).
Patients with cardiac diseases often have multiple risk factors for developing contrast
induced nephropathy (CIN), e.g. diabetes mellitus, advanced age, hypertension and chronic
kidney disease. Although the relationship between CTA and CIN has recently come to discussion
(AMACING trial; Nijssen et al. 2017), it is still desirable to minimise the CM volume used in
these patients. One method to reduce the CM volume is to personalise the injection protocols.
The personalisation of injection protocols to the individual patient is gaining more
attention in the field of CT imaging. The goal is to individualise the injection protocols to
a level, where the patient only receives the minimal amount of CM needed to acquire a
diagnostic scan, while maintaining a diagnostic image quality. Many techniques are available
and have been studied, e.g. adjustment of CM volume to scan protocol, CO, lean body weight
(LBW) and BW.
However, no data is available on which of these is the most beneficial method for the
personalisation of CM injection protocols. Therefore, the aim of this study is to assess the
performance of three different personalized injection protocols (based on CO, LBW and BW) in
CCTA with regard to image quality in comparison to previously used protocols in our
department. We hypothesize that the personalized injection protocols will be non-inferior,
provide a homogenous coronary enhancement (less non-diagnostic scans) in patients, and will
account for a reduction of CM volume in our department in comparison to the previously used
protocols.
Cardiac diseases still are the leading cause of death in the western world. Besides the high
mortality of the cardiac disease itself, recent studies have shown an increasing evidence of
the prognostic value of cardiac diseases, particularly coronary artery disease (CAD), in a
broad variety of other diseases. Especially in patients with oncological pathologies
undergoing radiotherapy or lung resection surgery [Ambrogi et al. 2003; Kanzaki et al. 2017;
Khakoo et al. 2008; Basacaraju et al. 2002; Fajardo et al. 1972]. Cardiac computed tomography
angiography (CCTA) is one of the standard non-invasive imaging techniques allowing imaging of
the heart and coronary arteries with a high temporal and spatial resolution. The high
sensitivity and negative predictive value (NPV) of CCTA make it a valuable tool in the
assessment of CAD. Especially to rule out CAD in patients with low to intermediate risk for
CAD [Hendel et al. 2006; Goldstein et al. 2011; Budoff et al. 2008; Meijboom et al. 2008;
Roffi et al. 2016].
The aim of CCTA is to achieve a high diagnostic accuracy, which depends on both optimal
intravascular enhancement (in Hounsfield Units (HU); minimal 325 HU) and contrast-to-noise
ratio (CNR). Optimal intravascular enhancement and CNR depend on multiple factors, such as
scan technique (e.g. tube voltage (kV) and tube potential), parameters of the administered
contrast material (CM) (e.g. concentration, flow rate) and patient related factors (e.g. body
weight (BW), heart rate or cardiac output [CO]) [Bae et al. 2004; Awai et al. 2004].
Dedicated CT protocols are necessary to image the heart and the coronary arteries. These
protocols require a correlation to the patient's electrocardiogram (ECG) in order to minimize
cardiac motion and deliver a sharp image of the heart and coronary arteries. Depending on the
heart rate of the patient, the scan can either be a prospectively ECG-triggered high-pitch or
adaptive sequence, or retrospectively ECG-gated helical scan.
Patients with cardiac diseases often have multiple risk factors for developing contrast
induced nephropathy (CIN), e.g. diabetes mellitus (DM), advanced age, hypertension,
cardiovascular disease and chronic kidney disease. Although the relationship between CTA and
CIN has recently come to discussion (AMACING trial; Nijssen et al. 2017), it is still
desirable to minimise the CM volume used in these patients. Multiple strategies have been
studied to reduce CM volume in CTA imaging [Kok et al 2016; Kok et al. 2015; Kok et al. 2016;
Kok et al. 2016, Mihl et al. 2016; Seehofnerova et al. 2015; Hendriks et al. 2016]. For
instance, lowering tube voltage to achieve a higher attenuation, the latter explained by the
fact that mean photon energy of lower tube voltage settings in the x-ray beam moves closer to
the K-edge of iodine (33.2 keV).
The personalisation of injection protocols to the individual patient is gaining more
attention in CT imaging, and the goal is to individualise the injection protocols to a level,
where the patient only receives the minimal amount of CM needed to make a diagnostic scan
with a diagnostic image quality. Besides the techniques mentioned above, other techniques are
possible, e.g. adjustment according to patients CO, lean body weight (LBW), and BW.
Both blood volume and CO increase with an increasing BW. When CO increases, the distribution
of CM is also increased. On one hand this results in a fastened test bolus arrival, on the
other hand in a decreased and shortened intravascular attenuation profile (in comparison to a
decreased CO) [Bae KT 2010]. Therefore, both timing and CM volume can be adjusted to CO in
order to achieve a similar intravascular attenuation profile.
LBW is a measurement for body fat percentage. It is known that fatty tissue is not as well
vascularised in comparison to muscle tissue. Thus with increasing BW due to fatty tissue, the
blood volume does not increase linear to BW. For instance, patients with a high BW due to
increased muscle tissue, need more CM volume compared to patients with a high BW due to fatty
tissue. The concept of LBW accounts for this fact [Bae KT 2010].
When adjusting CM volume to BW, less CM volume is needed with a lower BW in comparison to a
higher BW, due to the decreased blood volume and CO [Bae KT 2010].
The tube voltage, set by automated tube voltage selection (ATVS, CAREkV, Siemens, Berlin,
Germany), needs to be taken into account as well. CAREkV is a software program which chooses
the optimal tube voltage (kV) and tube current (mAs) settings for the individual patient,
based on their topograms, while maintaining a diagnostic image quality. Lower kV settings
result in a higher intravascular enhancement if the same amount of CM is used, thus giving
the potential to decrease CM volume in lower kV settings.
Since no data exist on the optimal method of choice, the aim of this study is to assess the
performance of three personalized injection protocols (CO, LBW and BW) in CCTA, in comparison
to previously used protocols, with regard to image quality. Secondly we want to assess the
presence and severity of CAD in patients undergoing CCTA with help of the coronary artery
disease reporting and data system (CAD-RADS).
A total of 330 patients will be included in this prospectively observer blinded randomized
controlled non-inferiority trial. All patients will be randomised in one of three groups (CO,
LBW and BW) with help of a randomisation software program (ALEA). The control group will
consist of 110 consecutive patients who will be included retrospectively.
;
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT05490303 -
HeartGuide: Preliminary Study
|
N/A | |
Completed |
NCT05070819 -
Atrial Natriuretic Peptide in Assessing Fluid Status
|
N/A | |
Not yet recruiting |
NCT04538469 -
Absent Visitors: The Wider Implications of COVID-19 on Non-COVID Cardiothoracic ICU Patients, Relatives and Staff
|
||
Not yet recruiting |
NCT04511403 -
Prevalence of Oral Mucosal Alterations In a Sample of Egyptian Patients With Cardiovascular Diseases: A Hospital- Based Cross-Sectional Study
|
||
Completed |
NCT02697760 -
The CZT Dynamic Myocardial Perfusion Imaging
|
||
Terminated |
NCT05157568 -
Pilot Randomized Clinical Trial of Live-streamed Cardiovascular Rehabilitation
|
N/A | |
Not yet recruiting |
NCT04160845 -
Non-invasive Forehead Skin Temperature in Cardiac Surgery
|
||
Completed |
NCT04500912 -
Comparison of the Supraflex Cruz 60 Micron Versus the Ultimaster Tansei 80 Micron in HBR PCI Population
|
N/A | |
Not yet recruiting |
NCT06438159 -
Impact of Mindfulness-Based Stress Reduction Meditation Practice on Patients After Cardiac Rehabilitation.
|
N/A | |
Recruiting |
NCT06154473 -
Assessment of Patients Undergoing Cardiac Surgery and Admitted to the Intensive Care Unit
|
||
Not yet recruiting |
NCT05877755 -
Validation of Multi-contrast, High-resolution Cardiac Magnetic Resonance Imaging
|
N/A | |
Completed |
NCT03394859 -
Electronic Medical Records and Genomics (eMERGE) Phase III
|
||
Recruiting |
NCT05055830 -
Opportunistic PK/PD Trial in Critically Ill Children (OPTIC)
|
||
Recruiting |
NCT04374799 -
Heparin vs Placebo for Cardiac Catheterization
|
Phase 3 | |
Completed |
NCT03174106 -
Longterm Follow-up of Cardiac Patients With an Smartphone-Application
|
N/A | |
Recruiting |
NCT05531253 -
Respired Gases in Patients Post Cardiac Surgery
|
||
Recruiting |
NCT04609228 -
Cardiac Surgery Outcomes in Blood-transfusion Acceptors and no Acceptors
|
||
Recruiting |
NCT06149143 -
Cardiac Performance System Data Collection Study - Minnesota
|
||
Recruiting |
NCT05725655 -
Hot Water Immersion After Myocardial Infarction
|
N/A | |
Recruiting |
NCT06073509 -
Atrial Fibrillation and Other Cardiac Arrhythmias and Diseases After Radiotherapy for Breast Cancer : Watch Your HeaRT
|