Cardiac Disease Clinical Trial
Official title:
Safety and Clinical Outcomes of Magnetic Resonance Imaging in Patients With Cardiac Implantable Electrical Devices
This protocol outlines a prospective study evaluating safety and clinical outcomes of magnetic resonance imaging (MRI) examinations performed on patients with cardiac implantable electrical devices (CIEDs) including pacemakers (PMs) and implantable cardioverter-defibrillators (ICDs). This prospective study aims to improve the evidence base regarding this common clinical scenario. Specifically, the investigators aim to address whether results of MRI in PM/ICD patients affect physician decision making related to clinical management strategy and planning treatment interventions. Further, this study will evaluate whether the results of MRI in these patients affects patient outcomes related to survival and adverse events during or after MRI scanning.
MRI is the preferred imaging modality for both acute and elective evaluation of many conditions. For example, for many diseases of the central nervous system, no other imaging modality provides the requisite soft tissue resolution to support critical care elements such as neurosurgical planning or assessment of intracranial malignancies. Historically, MRIs were considered contraindicated for patients with CIEDs including PMs and ICDs. However, studies have demonstrated very high utilization of MRIs among patients eligible for CIEDs. In many cases, alternative imaging is either insufficient or, as with CT-myelography, poses substantial risks or procedural hurdles that may be less favorable than the potential risks of an MRI. In recent years, a growing literature has suggested that MRIs can be performed safely in the setting of CIEDs if certain precautions are taken. Additionally, guidance documents have been released by professional societies including the American Heart Association (AHA) and the American College of Radiology (ACR) outlining recommended safety measures that can be taken to minimize risk and maximize benefit for patients in need of imaging. However, there are fewer data on performing MRIs in pacemaker-dependent patients with ICDs, who were excluded from the largest published study as well as the MagnaSafe Registry. Thus, demonstrating the safety and clinical utility of performing MRIs in this context is of high importance. In response to urgent clinical considerations, Beth Israel Deaconess Medical Center has established a clinical protocol to provide safe MRIs in cases of compelling clinical indications, with close supervision and oversight from Radiology and Cardiac Electrophysiology staff. Thus, the investigators now propose a prospective study to evaluate safety and clinical outcomes for patients treated under this clinical protocol. Specifically, this study proposes to perform a prospective clinical trial in patients with CIEDs that have a clinical need for MRI as outpatients to determine: 1. Safety according to the incidence rates of acute major and minor adverse events according to pre-specified definitions. 2. Clinical outcomes and scan utility affecting patients' survival and quality of life and treatment, including acute and longitudinal changes in device parameters, the need for system revision, and proportion of MRI findings influencing clinical management including medical or surgical interventions, and diagnostic or prognostic changes. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT05490303 -
HeartGuide: Preliminary Study
|
N/A | |
Completed |
NCT05070819 -
Atrial Natriuretic Peptide in Assessing Fluid Status
|
N/A | |
Not yet recruiting |
NCT04538469 -
Absent Visitors: The Wider Implications of COVID-19 on Non-COVID Cardiothoracic ICU Patients, Relatives and Staff
|
||
Not yet recruiting |
NCT04511403 -
Prevalence of Oral Mucosal Alterations In a Sample of Egyptian Patients With Cardiovascular Diseases: A Hospital- Based Cross-Sectional Study
|
||
Completed |
NCT02697760 -
The CZT Dynamic Myocardial Perfusion Imaging
|
||
Terminated |
NCT05157568 -
Pilot Randomized Clinical Trial of Live-streamed Cardiovascular Rehabilitation
|
N/A | |
Not yet recruiting |
NCT04160845 -
Non-invasive Forehead Skin Temperature in Cardiac Surgery
|
||
Completed |
NCT04500912 -
Comparison of the Supraflex Cruz 60 Micron Versus the Ultimaster Tansei 80 Micron in HBR PCI Population
|
N/A | |
Not yet recruiting |
NCT06438159 -
Impact of Mindfulness-Based Stress Reduction Meditation Practice on Patients After Cardiac Rehabilitation.
|
N/A | |
Recruiting |
NCT06154473 -
Assessment of Patients Undergoing Cardiac Surgery and Admitted to the Intensive Care Unit
|
||
Not yet recruiting |
NCT05877755 -
Validation of Multi-contrast, High-resolution Cardiac Magnetic Resonance Imaging
|
N/A | |
Completed |
NCT03394859 -
Electronic Medical Records and Genomics (eMERGE) Phase III
|
||
Recruiting |
NCT05055830 -
Opportunistic PK/PD Trial in Critically Ill Children (OPTIC)
|
||
Recruiting |
NCT04374799 -
Heparin vs Placebo for Cardiac Catheterization
|
Phase 3 | |
Completed |
NCT03174106 -
Longterm Follow-up of Cardiac Patients With an Smartphone-Application
|
N/A | |
Recruiting |
NCT05531253 -
Respired Gases in Patients Post Cardiac Surgery
|
||
Recruiting |
NCT04609228 -
Cardiac Surgery Outcomes in Blood-transfusion Acceptors and no Acceptors
|
||
Recruiting |
NCT06149143 -
Cardiac Performance System Data Collection Study - Minnesota
|
||
Recruiting |
NCT05725655 -
Hot Water Immersion After Myocardial Infarction
|
N/A | |
Recruiting |
NCT06073509 -
Atrial Fibrillation and Other Cardiac Arrhythmias and Diseases After Radiotherapy for Breast Cancer : Watch Your HeaRT
|