Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT03886454
Other study ID # IRB # 12489
Secondary ID
Status Completed
Phase
First received
Last updated
Start date June 19, 2017
Est. completion date July 1, 2019

Study information

Verified date August 2019
Source Tufts Medical Center
Contact n/a
Is FDA regulated No
Health authority
Study type Observational

Clinical Trial Summary

This study aims to characterize airflow patterns during bronchoscopy under conscious sedation, and determine the incidence of obstructive and central respiratory events. The investigators also plan to monitor the degree and frequency of oxygen desaturation throughout the procedure. To achieve this, investigators use a physiologic monitoring device (NOX T3, K082113) that has been FDA approved for the screening and diagnosis of sleep disordered breathing [1]. The results from this pilot study will be used to assess the feasibility of a prospective study utilizing continuous external negative pressure (Pneuway). This negative pressure is applied through a neck mask to alleviate upper airway collapsibility and can potentially decrease the number of apneas during bronchoscopy under conscious sedation [2].


Description:

Background and Rationale:

Diagnostic bronchoscopic procedures are commonly performed in patients with various forms of pulmonary disorders associated with abnormal chest imaging. During these procedures, the vocal cords are intubated using a flexible scope. Patients need sedation and analgesia, and conscious sedation is typically administered. Hypoxemia is a potential complication during bronchoscopy. Contributing factors in addition to the underlying lung pathology, include depression of the respiratory center and decreased upper airway muscle tone that occur during conscious sedation [3]. Upper airway obstruction including obstructive apnea is often unrecognized during these procedures till hypoxemia is apparent [4]. Propofol, a common drug used for conscious sedation, is known to cause respiratory depression, and potentially central and/or obstructive apneas with a direct dose-response pattern [5]. Others, including benzodiazepines and opiates, can also cause respiratory depression leading to central or obstructive events. Respiratory depression is potentiated when any of the above medications are combined [6].

Objectives:

The objective of the study is to identify the incidence of airflow limitation during bronchoscopy under conscious sedation, and further characterize it as obstructive or central. The primary endpoint is the incidence of obstructive and central apneic events during bronchoscopic procedures. The secondary outcomes include incidence of oxygen desaturation and need for escalation of care.

Study Design:

After informed consent is obtained, the NOX-T3 monitoring system, a commonly used portable sleep device that detects obstructive and central apneas, is placed prior to starting the procedure, and remains in place up to 30 minutes following the procedure. The NOX-T3 monitoring system includes a nasal cannula that sits over the nares, an elastic band that goes around the chest, and another one that goes around the abdomen, and a finger probe that is placed on the index finger. All subjects undergo bronchoscopy with standard of care including the monitoring of blood pressure, respiratory rate and oxygen saturation. All subjects have the NOX-T3 applied in addition to standard of care monitoring. Data is assessed following the completion of the procedure. Subjects' participation in this study ends at the completion of their standard of care visit. All the NOX-T3 studies are scored and interpreted by study investigators.

Data Management:

This is an observational and descriptive study with an estimated sample size of 30. Data collected will be reviewed with a statistician and investigators will report on patients' demographics. The study investigators will also present the incidence of apneic respiratory events and characterize them as obstructive or centrals. Investigators will further differentiate obstructive respiratory events to either apneas or hypopnea. Data on oxygen desaturations unrelated to apneic events will also be recorded.


Recruitment information / eligibility

Status Completed
Enrollment 33
Est. completion date July 1, 2019
Est. primary completion date June 1, 2019
Accepts healthy volunteers No
Gender All
Age group 18 Years and older
Eligibility Inclusion Criteria:

1. Patients with respiratory pathology that require bronchoscopy for further diagnostic evaluation, as part of standard of care

2. Age of 18 years or older.

3. Our study does not include the recruitment of vulnerable populations such as cognitively impaired adults, pregnant women, pregnant minors, minors, wards of the state, non-viable neonates, neonates of uncertain viability and prisoners.

Exclusion Criteria:

1. Oxygen requirement of more than 4 Liter prior to procedure.

2. Intubation or any airway support.

3. Presence of severe cardiopulmonary or neurologic disease as determined by the investigator.

4. Nasal congestion/obstruction preventing proper placement and monitoring of air flow

5. Inability to provide informed consent.

6. All vulnerable population mentioned above.

Study Design


Locations

Country Name City State
United States Tufts Medical Center Boston Massachusetts

Sponsors (2)

Lead Sponsor Collaborator
Tufts Medical Center Natalie V. Zucker Research Grant

Country where clinical trial is conducted

United States, 

References & Publications (6)

Cairns A, Wickwire E, Schaefer E, Nyanjom D. A pilot validation study for the NOX T3(TM) portable monitor for the detection of OSA. Sleep Breath. 2014 Sep;18(3):609-14. doi: 10.1007/s11325-013-0924-2. Epub 2014 Jan 19. — View Citation

Eastwood PR, Platt PR, Shepherd K, Maddison K, Hillman DR. Collapsibility of the upper airway at different concentrations of propofol anesthesia. Anesthesiology. 2005 Sep;103(3):470-7. — View Citation

Hillman DR, Platt PR, Eastwood PR. The upper airway during anaesthesia. Br J Anaesth. 2003 Jul;91(1):31-9. Review. — View Citation

José RJ, Shaefi S, Navani N. Sedation for flexible bronchoscopy: current and emerging evidence. Eur Respir Rev. 2013 Jun 1;22(128):106-16. doi: 10.1183/09059180.00006412. Review. — View Citation

Kais SS, Klein KB, Rose RM, Endemann S, Coyle WJ. Continuous negative external pressure (cNEP) reduces respiratory impairment during screening colonoscopy: a pilot study. Endoscopy. 2016 Jun;48(6):584-7. doi: 10.1055/s-0042-102533. Epub 2016 Apr 25. — View Citation

Vargo JJ, Zuccaro G Jr, Dumot JA, Conwell DL, Morrow JB, Shay SS. Automated graphic assessment of respiratory activity is superior to pulse oximetry and visual assessment for the detection of early respiratory depression during therapeutic upper endoscopy. Gastrointest Endosc. 2002 Jun;55(7):826-31. — View Citation

Outcome

Type Measure Description Time frame Safety issue
Primary The incidence of obstructive and central apneic events. Obstructive apnea are defined as more than 90% cessation of air-flow that lasts for at least 10 seconds, despite the presence of respiratory and abdominal muscle effort. Obstructive hypopnea is when more than 30% cessation of air-flow occurs that lasts for at least 10 seconds, and is associated with oxygen desaturation of at least 3% from baseline. Central apnea is when cessation of air-flow occurs secondary to absent respiratory and abdominal muscle effort, that lasts for at least 10 seconds. Throughout the bronchoscopic procedure.
Secondary Oxygen desaturation Oxygen desaturation of more than 3% from baseline which are unrelated to apneic events. Throughout the bronchoscopic procedure.
Secondary Need for escalation of care Need for escalation of care, including but not limited to, increasing supplemental oxygen, jaw thrust, patient stimulation or interrupting the administration of conscious sedation drug. Throughout the bronchoscopic procedure.
See also
  Status Clinical Trial Phase
Terminated NCT03581474 - Evaluation of BAL Procedure With Ambu aScope 3 Large in Patients in an ICU Setting N/A
Completed NCT03294213 - Prospective Non-interventional Evaluation of Intubation and Intensive Care Use of the New aScope™ 4 Broncho and aView
Completed NCT06116955 - The Application of Balanced Propofol Sedation in Fiberoptic Bronchoscopy
Withdrawn NCT03613792 - Remifentanil Plus Ketamine for Dynamic Flexible Bronchoscopy Phase 4
Completed NCT04016480 - HFNC During Bronchoscopy for Bronchoalveolar Lavage N/A
Recruiting NCT01100554 - Upper Airway Collapsibility Evaluation in Different Sedative Levels by Sleep Endoscopy N/A
Completed NCT00861835 - Trial of Rapid On-Site Evaluation of Transbronchial Needle Aspirate (TBNA) N/A
Completed NCT05154916 - The Effect of Virtual Reality Based Relaxation Program on Patients to be Performed Bronchoscopy N/A
Completed NCT03086408 - Transnasal Humidified Rapid-Insufflation Ventilatory Exchange (THRIVE) and Diagnostic Bronchoscopy N/A
Active, not recruiting NCT04884061 - Narrow Band Imaging Bronchoscopy During SARS-CoV2 Infection
Completed NCT05875662 - Pulmonary Ventilation After Fiberoptic Bronchoscopy Using EIT
Completed NCT00684684 - Safety and Feasibility Study of the Chartis System Phase 1
Completed NCT03521505 - Dexmedetomidine for Sedation of Endobronchial Ultrasound-guided Transbronchial Needle Aspiration Phase 4
Not yet recruiting NCT03856073 - The Training and Evaluate Effect on Clinical Airway Management for Novices. N/A
Not yet recruiting NCT03854760 - The Training and Evaluate Effect on Clinical Airway Management N/A
Recruiting NCT05912985 - Three Different Oxygenation Strategies in Bronchoscopy Procedures Under Sedation
Enrolling by invitation NCT05692362 - Measure Airway Compliance by Endobronchial Optical Coherence Tomography
Completed NCT03419546 - Clinical Validation Trial of a Single-use Bronchoscope (Ambu® aScope ™ 4)
Not yet recruiting NCT03983889 - Sedation Strategies for Diagnostic Bronchoscopy 2 N/A
Not yet recruiting NCT03983915 - Sedation Strategies for Therapeutic Bronchoscopy 2 N/A