Coronary Artery Disease Clinical Trial
Official title:
Isolated Cardiotomy Circuit for Re-infusion of Unwashed Shed Blood During Off-pump Coronary Artery Surgery
To assess the efficacy and side-effects of re-infusion of unwashed shed blood during off-pump coronary artery surgery using a novel cardiotomy circuit.
Introduction Blood transfusion is often required during cardiac surgical operations, and may be associated with known risks and complications. Off-pump coronary artery surgery has been shown to be associated with reduced need for blood transfusion, and cell-savers are widely used as an additional method for reducing blood transfusion demands. Auto-transfusion of unwashed suctioned blood intra-operatively is thought to increase the inflammatory response and infective complications, but data related to this approach are scares. Aims To assess the effects and benefits of using an isolated cardiotomy circuit for re-infusion of unwashed shed blood during off-pump surgery and compare it to the conventional no re-infusion technique. Assessments will focus on: - clinical outcome - transfusion requirements - inflammatory response - alveolar/arterial oxygen pressure gradients - cognitive status - cost-benefit Study design A prospective study involving patients undergoing off-pump coronary artery bypass surgery. Patients will be randomized to two groups; an isolated cardiotomy circuit for re-infusion of unwashed shed blood will be used in group (a) and the conventional no re-infusion technique will be used in group (b). Participants Patients undergoing off-pump coronary artery bypass surgery. Setting Damascus University Cardiac Surgery Hospital ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT06030596 -
SPECT Myocardial Blood Flow Quantification for Diagnosis of Ischemic Heart Disease Determined by Fraction Flow Reserve
|
||
Completed |
NCT04080700 -
Korean Prospective Registry for Evaluating the Safety and Efficacy of Distal Radial Approach (KODRA)
|
||
Recruiting |
NCT03810599 -
Patient-reported Outcomes in the Bergen Early Cardiac Rehabilitation Study
|
N/A | |
Recruiting |
NCT06002932 -
Comparison of PROVISIONal 1-stent Strategy With DEB Versus Planned 2-stent Strategy in Coronary Bifurcation Lesions.
|
N/A | |
Not yet recruiting |
NCT06032572 -
Evaluation of the Safety and Effectiveness of the VRS100 System in PCI (ESSENCE)
|
N/A | |
Recruiting |
NCT04242134 -
Drug-coating Balloon Angioplasties for True Coronary Bifurcation Lesions
|
N/A | |
Recruiting |
NCT05308719 -
Nasal Oxygen Therapy After Cardiac Surgery
|
N/A | |
Completed |
NCT04556994 -
Phase 1 Cardiac Rehabilitation With and Without Lower Limb Paddling Effects in Post CABG Patients.
|
N/A | |
Recruiting |
NCT05846893 -
Drug-Coated Balloon vs. Drug-Eluting Stent for Clinical Outcomes in Patients With Large Coronary Artery Disease
|
N/A | |
Recruiting |
NCT06027788 -
CTSN Embolic Protection Trial
|
N/A | |
Recruiting |
NCT05023629 -
STunning After Balloon Occlusion
|
N/A | |
Completed |
NCT04941560 -
Assessing the Association Between Multi-dimension Facial Characteristics and Coronary Artery Diseases
|
||
Completed |
NCT04006288 -
Switching From DAPT to Dual Pathway Inhibition With Low-dose Rivaroxaban in Adjunct to Aspirin in Patients With Coronary Artery Disease
|
Phase 4 | |
Completed |
NCT01860274 -
Meshed Vein Graft Patency Trial - VEST
|
N/A | |
Recruiting |
NCT06174090 -
The Effect of Video Education on Pain, Anxiety and Knowledge Levels of Coronary Bypass Graft Surgery Patients
|
N/A | |
Completed |
NCT03968809 -
Role of Cardioflux in Predicting Coronary Artery Disease (CAD) Outcomes
|
||
Terminated |
NCT03959072 -
Cardiac Cath Lab Staff Radiation Exposure
|
||
Recruiting |
NCT04566497 -
Assessment of Adverse Outcome in Asymptomatic Patients With Prior Coronary Revascularization Who Have a Systematic Stress Testing Strategy Or a Non-testing Strategy During Long-term Follow-up.
|
N/A | |
Recruiting |
NCT05065073 -
Iso-Osmolar vs. Low-Osmolar Contrast Agents for Optical Coherence Tomography
|
Phase 4 | |
Completed |
NCT05096442 -
Compare the Safety and Efficacy of Genoss® DCB and SeQuent® Please NEO in Korean Patients With Coronary De Novo Lesions
|
N/A |