Clinical Trial Summary
This study aims to assess whether removing single elements of the standardized office BP
measurement procedure will affect the accuracy towards the mean awake ambulatory BP. Four
arms are planned in a randomized order: 1) full standardized procedure, 2) standardized
procedure but with cuff placed on a sleeve, 3) standardized procedure but arm resting
vertically, 4) standardized procedure but with non-validated device.
This is a pilot study to inform on the sample size required to perform adequately powered
large scale studies.
Description:
Accurate and reliable blood pressure (BP) measurements are key for hypertension management.
To this regard, all hypertension societies recommend using highly standardized automated
oscillometric office BP measurements (AOBP) as a way to minimise measurement biases, enhance
reproducibility and allow comparability. The standardized AOBP procedure emphasizes the need
to measure BP in a controlled environment with optimal body positioning, the use of an
appropriately sized cuff over a bare arm and a clinically validated oscillometric BP devices.
It is also recommended to average >2 measurements at 30-60 seconds intervals after several
minutes of seated rest alone in a quiet room. As such, important barriers exist to implement
standardized AOBP in real-life settings, as this procedure requires time, space and patient
mobility.
A 2017 meta-analysis evaluated the impact of several elements of oscillometric and
auscultatory BP readings on systolic and diastolic BP levels. It showed that while most
components of BP measurements appear to influence BP, the majority of included studies were
of relatively low methodological quality (including unstandardized BP measurements, lack of
randomisation, auscultatory method, absence or differences in rest periods, single readings,
single cuff size) and almost none were compared with th gold-standard BP measurement, i.e
average awake ambulatory BP measurements (ABPM). Since, two meta-analyses specifically
assessing the effect of attendance during AOBP were published and showed conflicting results.
While important components of AOBP (rest period and cuff size) were recently tested using a
rigorous methodology, data is still missing for most elements.
Simplifying the AOBP procedure could result in improvements in acceptability and
implementation. The need to perform this highly standardized procedure exerts pressure on
patients, providers and administrative staff. Indeed, patients need to be properly seated
alone in a quiet dedicated room in a chair with an arm rest that need to be adjustable to
position the upper arm at heart level. This setup is seldom available apart in highly
specialized hypertension clinics. Also, the arm must be bare, which can bring discomfort to
patients with the requirement to remove their clothing or roll up the sleeves, which
introduces another potential source of inaccuracy due to the tourniquet effect or the
inability to completely uncover the upper arm. It can also introduce significant time delays
in a clinical setting for less mobile patients. Furthermore, the BP device must be clinically
validated for its accuracy. The lack of regulation and the ease of online purchase means many
patients may be drawn to purchasing less expensive non-validated devices. While this problem
may be more widespread in the home setting, not all office BP measuring devices are validated
and recommended by Hypertension Canada.
The primary objective of the SIMPLE-AOBP study is to assess whether foregoing, or
simplifying, specific elements of the AOBP procedure affects its accuracy towards the
gold-standard mean awake ABPM. This study will employ a rigorous methodology (highly
standardized measurements, identical settings and rest periods, randomization, blinded
assessment of outcomes, averaged multiple BP measurements) to minimise measurement biases not
related to the studies elements. The study will focus on three easily addressable elements:
1) the need the measure BP on a bare arm, 2) the requirement of supporting the arm at heart
level and 3) the need to use a validated BP device. This trial will provide important pilot
data to help design adequately powered large scale studies.