Blood Pressure Clinical Trial
Official title:
Comparison of 3 Techniques for Blood Pressure Measurements During Interventional Neuroradiology Procedures
Some observational studies demonstrated that hypotension was associated with post-operative morbidity. During neuroradiological procedures, cerebral perfusion pressure should be cautiously maintained and hypertension should also be avoided. So, a precise arterial pressure measurement is needed during this procedures. A continuous monitoring of arterial pressure needed the placement of an arterial catheter in radial artery. The placement of this catheter might be long, difficult and incompatible with emergency neuroradiological procedure (such as thrombectomy). Then, this invasive technique is associated with several minor and major side effects such as: pain, infection, thrombosis, hematoma. The Clearsight®, commercialized by Edwards Life Science Company®, is a non invasive device which mesure continuously arterial pressure with Volume-Clamp method. In operating room, some studies found a good accuracy between Clearsight® and other invasive monitoring system. There is no description of the use of Clearsight® during neuroradiological procedures. The investigators hypothesized that Clearsight® measurement of arterial pressure are concordant with arterial pressure measure with the placement of an arterial catheter. The investigators also plan to evaluate accuracy of intermittent non invasive pressure measurement with traditional cuff.
n/a
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT03255187 -
Effect of Dietary Supplemental Fish Oil in Alleviating Health Hazards Associated With Air Pollution
|
N/A | |
Completed |
NCT05997303 -
Continuous Norepinephrine Administration and Blood Pressure Stability During Anesthetic Induction
|
N/A | |
Recruiting |
NCT04575194 -
Study of the Cardiometabolic Effects of Obesity Pharmacotherapy
|
Phase 4 | |
Completed |
NCT03918486 -
Caretaker vs. Routine Blood Pressure Sphygmomanometer
|
||
Completed |
NCT03410342 -
The Effects of Types of Fruits and Vegetables on Vascular Function
|
N/A | |
Active, not recruiting |
NCT05062161 -
Sleep Duration and Blood Pressure During Sleep
|
N/A | |
Not yet recruiting |
NCT04087070 -
Blood Pressure Estimation Using Noninvasive Biosignals During Pediatric Anesthesia
|
||
Completed |
NCT03294928 -
Arterial Waveform Analysis Applying Different Positive End-Expiratory Pressure (PEEP) Levels in Healthy Volunteers
|
N/A | |
Completed |
NCT03859934 -
Metabolic Effects of Melatonin Treatment
|
Phase 1 | |
Completed |
NCT03997461 -
Comparison of Arterial Tonometry Sensor With Standard Oscillometric Blood Pressure Monitoring Device
|
N/A | |
Completed |
NCT03290716 -
Diet, ExerCIse and carDiovascular hEalth (DECIDE) - Salt Reduction Strategies for the Elderly in Nursing Homes in China
|
N/A | |
Recruiting |
NCT06460233 -
Blood Pressure Changes After Bariatric Surgery
|
||
Recruiting |
NCT05196048 -
Blood Pressure Sensor of Watch-type Device With ECG Technology
|
||
Terminated |
NCT03325933 -
Resistance Training and Cardiometabolic Health
|
N/A | |
Not yet recruiting |
NCT06405880 -
Pharmacist Case Finding and Intervention for Vascular Prevention Trial
|
N/A | |
Completed |
NCT02924454 -
Effects of Lipid Emulsion on the Pharmacokinetic and Pharmacodynamic Properties of Metoprolol.
|
Phase 4 | |
Completed |
NCT02451059 -
Reducing Socioeconomic Disparities in Health at Pediatric Visits
|
N/A | |
Active, not recruiting |
NCT02670967 -
Effects of Soluble Fiber on Blood Pressure: A Meta-analysis of Randomly-controlled Trials
|
N/A | |
Completed |
NCT02271633 -
Nitrate Supplementation; Source
|
Phase 4 | |
Completed |
NCT02239744 -
Intervention Study on the Health Impact of Air Filters in Chinese Adults
|
N/A |