Clinical Trials Logo

Clinical Trial Summary

Comparison of Blood Pressures obtained with the Pulse Decomposition Algorithm and Intra-Arterial Catheters in ICU Patients


Clinical Trial Description

The object of the work presented here was to validate a new approach to tracking blood pressure that is based on the pulse analysis of the peripheral arterial pressure pulse. The approach, referred to as the Pulse Decomposition Analysis (PDA) model, goes beyond traditional pulse analysis by invoking a physical model that comprehensively links the components of the peripheral pressure pulse envelope with two reflection sites in the central arteries.

In these experiments, approved by the University of Virginia Institutional Review Board, the arterial blood pressures of patients (23 m/11 f, mean age: 44.05 y, SD: 13.9 y, mean height: 173.3 cm, SD: 9.4 cm, mean weight: 95.3 kg, SD: 27.4 kg) hospitalized in University of Virginia Medical Intensive Care Units (MICUs) were monitored using radial intra-arterial catheters, while the CareTaker system collected pulse line shapes at the lower phalange of the thumb of the ipsilateral hand.

Systolic and diastolic blood pressures continuously collected from the arterial catheter and CT were compared. Pearson correlation coefficients were calculated between arterial catheter and CT blood pressure measurements and a Bland-Altman analysis was created. Results were within the limits established for the validation of automatic arterial pressure monitoring (AAMI/ANSI/ISO 81060-1:2013). ;


Study Design

Observational Model: Cohort, Time Perspective: Retrospective


Related Conditions & MeSH terms


NCT number NCT02479724
Study type Observational
Source Empirical Technologies Corporation
Contact
Status Completed
Phase N/A
Start date January 2012
Completion date June 2013

See also
  Status Clinical Trial Phase
Completed NCT03255187 - Effect of Dietary Supplemental Fish Oil in Alleviating Health Hazards Associated With Air Pollution N/A
Completed NCT05997303 - Continuous Norepinephrine Administration and Blood Pressure Stability During Anesthetic Induction N/A
Recruiting NCT04575194 - Study of the Cardiometabolic Effects of Obesity Pharmacotherapy Phase 4
Completed NCT03918486 - Caretaker vs. Routine Blood Pressure Sphygmomanometer
Completed NCT03410342 - The Effects of Types of Fruits and Vegetables on Vascular Function N/A
Active, not recruiting NCT05062161 - Sleep Duration and Blood Pressure During Sleep N/A
Not yet recruiting NCT04087070 - Blood Pressure Estimation Using Noninvasive Biosignals During Pediatric Anesthesia
Completed NCT03294928 - Arterial Waveform Analysis Applying Different Positive End-Expiratory Pressure (PEEP) Levels in Healthy Volunteers N/A
Completed NCT03859934 - Metabolic Effects of Melatonin Treatment Phase 1
Completed NCT03997461 - Comparison of Arterial Tonometry Sensor With Standard Oscillometric Blood Pressure Monitoring Device N/A
Completed NCT03290716 - Diet, ExerCIse and carDiovascular hEalth (DECIDE) - Salt Reduction Strategies for the Elderly in Nursing Homes in China N/A
Recruiting NCT05196048 - Blood Pressure Sensor of Watch-type Device With ECG Technology
Recruiting NCT06460233 - Blood Pressure Changes After Bariatric Surgery
Terminated NCT03325933 - Resistance Training and Cardiometabolic Health N/A
Not yet recruiting NCT06405880 - Pharmacist Case Finding and Intervention for Vascular Prevention Trial N/A
Completed NCT02924454 - Effects of Lipid Emulsion on the Pharmacokinetic and Pharmacodynamic Properties of Metoprolol. Phase 4
Completed NCT02451059 - Reducing Socioeconomic Disparities in Health at Pediatric Visits N/A
Active, not recruiting NCT02670967 - Effects of Soluble Fiber on Blood Pressure: A Meta-analysis of Randomly-controlled Trials N/A
Completed NCT02271633 - Nitrate Supplementation; Source Phase 4
Completed NCT02239744 - Intervention Study on the Health Impact of Air Filters in Chinese Adults N/A