Clinical Trials Logo

Clinical Trial Summary

Ambulatory Blood Pressure Monitoring (ABPM) potentially offers a superior way to screen children for entry into antihypertensive trials, assuring that only those with true hypertension are enrolled.10 In addition, ABPM offers a better method to measure response to drug therapy.11-16 The ABPM device most commonly used in children (Spacelabs 90217 - Issaquah, Washington) has not been independently validated for use in this population. In 1993, the British Hypertension Society (BHS) published a protocol for validating ABPM devices, including guidance for validation studies in children.17 More recently, the Working Group on Blood Pressure Monitoring of the European Society of Hypertension published revisions to these guidelines, but did not include children in this update.18 Unfortunately, the original BHS protocol suggests using a smaller group of children than the protocol outlines for adults. Since BP in children is more variable than in adults, this guidance is unlikely to be adequate for children. Hence, a large, stringent validation study needs to be conducted in a cohort of children using the methods similar to those used to validate the device in adults. Performance of the proposed validation study is needed to allow for the incorporation of ABPM into clinical trial designs of anti-hypertensives in children which will ultimately allow for more accurate identification of the hypertensive population and determination of response to therapy along with allowing for assessment of the chronobiologic profile of drug response over the dosing interval.9


Clinical Trial Description

The diagnosis and treatment of hypertension remains a challenge in children and adolescents.1 At present the diagnosis is made during medical encounters and depends on randomly applied auscultatory or oscillometric techniques.2 These measurements are influenced by multiple factors including diurnal variation, stress related effects (most notably the fact that the measurement is being performed in a physician's office or clinic), observer bias and the measurement process itself. In addition, these standard approaches provide little information regarding blood pressure and its variability in the patients' ambient environments.3,4 If and when a diagnosis of hypertension is made, lifestyle changes are often prescribed. In children and adolescents these recommendations meet with mixed results that often frustrate patients and families as well as caregivers. In most cases, where sufficient concern exists regarding the long-term health of end organs such as the heart, kidney, eye and brain, pharmacotherapy is recommended. Unfortunately, in these instances drugs are prescribed with little information to guide proper, age-related dosing or safety assessment. In studies conducted over the last decade more than half of the agents marketed for adults with hypertension failed to demonstrate sufficient activity in children and adolescents to meet regulatory requirements for labeling.5 While a significant amount of this apparent ambiguity appears to be related to the design of the studies assessing the efficacy and safety of these drugs in pediatric patients, perhaps a more significant problem in these studies was the determination of who is actually hypertensive in the first place. This supplement addresses this issue directly by introducing an innovative approach to the diagnosis of hypertension in children and adolescents. Once validated, ambulatory BP monitoring may be used to describe and model the chronobiological patterns of blood pressure among patients who have been recently diagnosed with hypertension using standard clinical criteria. This is a unique opportunity to assess treatment naïve patients and compare an innovative new approach to what is currently the gold standard. The current project is designed specifically to validate the use of ambulatory blood pressure monitoring (ABPM) in children and adolescents so that it may be used as a clinical tool for unambiguously making the diagnosis of hypertension in this patient population and then be used to guide pharmacotherapeutic intervention. The use of ABPM in children was first documented in 19916 and has subsequently been employed in children as young as 2 months of age. Despite its adjunctive use by more than 60% of pediatric nephrologists in North America, the device currently used in the majority of pediatric practices and research centers has never been validated in a pediatric population. In contrast, ABPM has become a world-wide standard for monitoring blood pressure in adults with suspected hypertension. It offers the advantages of multiple measurements of a dynamic process over a protracted period of time and permits the evaluation of diurnal patterns and nocturnal disease. It also offers distinct advantages in monitoring patients in their natural environment without observer bias while permitting objective assessment of apparent drug resistance and hypotensive events that might occur on therapy. Finally, ABPM measurements have been demonstrated to better correlate with cardiovascular morbidity and mortality than casual measurements.7 They also correlate with end organ damage in children.8 Performance of the proposed validation study is needed to allow for incorporation of ABPM into clinical trial designs related to the diagnosis and treatment of hypertension in children. ABPM will ultimately allow for more accurate determination of response to therapy and asses the chronobiologic profile of drug response over the dosing interval. Of the devices currently marketed, the Spacelabs 90217 offers the range of cuff sizes required by the pediatric population. Thus, it is this monitor that will be validated. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT01070342
Study type Observational
Source University Hospitals Cleveland Medical Center
Contact
Status Completed
Phase
Start date February 2010
Completion date February 2011

See also
  Status Clinical Trial Phase
Completed NCT03255187 - Effect of Dietary Supplemental Fish Oil in Alleviating Health Hazards Associated With Air Pollution N/A
Completed NCT05997303 - Continuous Norepinephrine Administration and Blood Pressure Stability During Anesthetic Induction N/A
Recruiting NCT04575194 - Study of the Cardiometabolic Effects of Obesity Pharmacotherapy Phase 4
Completed NCT03918486 - Caretaker vs. Routine Blood Pressure Sphygmomanometer
Completed NCT03410342 - The Effects of Types of Fruits and Vegetables on Vascular Function N/A
Active, not recruiting NCT05062161 - Sleep Duration and Blood Pressure During Sleep N/A
Not yet recruiting NCT04087070 - Blood Pressure Estimation Using Noninvasive Biosignals During Pediatric Anesthesia
Completed NCT03294928 - Arterial Waveform Analysis Applying Different Positive End-Expiratory Pressure (PEEP) Levels in Healthy Volunteers N/A
Completed NCT03859934 - Metabolic Effects of Melatonin Treatment Phase 1
Completed NCT03997461 - Comparison of Arterial Tonometry Sensor With Standard Oscillometric Blood Pressure Monitoring Device N/A
Completed NCT03290716 - Diet, ExerCIse and carDiovascular hEalth (DECIDE) - Salt Reduction Strategies for the Elderly in Nursing Homes in China N/A
Recruiting NCT06460233 - Blood Pressure Changes After Bariatric Surgery
Recruiting NCT05196048 - Blood Pressure Sensor of Watch-type Device With ECG Technology
Terminated NCT03325933 - Resistance Training and Cardiometabolic Health N/A
Not yet recruiting NCT06405880 - Pharmacist Case Finding and Intervention for Vascular Prevention Trial N/A
Completed NCT02924454 - Effects of Lipid Emulsion on the Pharmacokinetic and Pharmacodynamic Properties of Metoprolol. Phase 4
Completed NCT02451059 - Reducing Socioeconomic Disparities in Health at Pediatric Visits N/A
Active, not recruiting NCT02670967 - Effects of Soluble Fiber on Blood Pressure: A Meta-analysis of Randomly-controlled Trials N/A
Completed NCT02239744 - Intervention Study on the Health Impact of Air Filters in Chinese Adults N/A
Completed NCT02271633 - Nitrate Supplementation; Source Phase 4