Blood Pressure Clinical Trial
Official title:
A Comparison of Ketofol (Ketamine and Propofol Admixture) vs. Propofol as Induction Agents on Hemodynamic Parameters
Verified date | March 2013 |
Source | Mayo Clinic |
Contact | n/a |
Is FDA regulated | No |
Health authority | United States: Institutional Review Board |
Study type | Interventional |
This is a pilot study to compare the hemodynamic changes that occur during induction with a novel drug combination known as ketofol (propofol and ketamine admixture with that of propofol alone (prototypic anesthesia induction agent). Propofol and ketamine are widely used as induction agents and their effects on patient hemodynamics are well known. Some of these drug-induced hemodynamic changes are undesirable and lead to deleterious effects on patient hemodynamics. We seek to investigate the hemodynamic changes associated with a novel drug combination known as ketofol (ketamine/propofol admixture) during induction and compare them to propofol. If we determine that the changes produced by ketofol are favorable compared with propofol, we then will seek to test its use in the trauma setting in a subsequent randomized controlled trial.
Status | Completed |
Enrollment | 85 |
Est. completion date | March 2011 |
Est. primary completion date | March 2011 |
Accepts healthy volunteers | No |
Gender | Both |
Age group | 18 Years to 60 Years |
Eligibility |
Inclusion Criteria: - American Society of Anesthesiologists (ASA) physical status I and II who are to undergo elective general, urologic, orthopedic, plastic, or gynecologic surgery. Exclusion Criteria: - patients with age less than 18 yr or over 60 yr, - emergency surgery, - patients undergoing neurosurgical procedures, - any procedure with adjunctive analgesia, - any patient on chronic opiate use, - females who are known to be pregnant, - patients who had ingested psychotropic or sedative medication within one month of investigation, - patients with personality disorders, - weight greater than 20% of ideal, and - any known contraindications to ketamine or propofol. |
Allocation: Randomized, Endpoint Classification: Pharmacokinetics/Dynamics Study, Intervention Model: Parallel Assignment, Masking: Double Blind (Subject, Caregiver, Investigator, Outcomes Assessor), Primary Purpose: Prevention
Country | Name | City | State |
---|---|---|---|
United States | Dartmouth Hitchcock Medical Center | Lebanon | New Hampshire |
Lead Sponsor | Collaborator |
---|---|
Mayo Clinic | Dartmouth-Hitchcock Medical Center |
United States,
Smischney NJ, Beach ML, Loftus RW, Dodds TM, Koff MD. Ketamine/propofol admixture (ketofol) is associated with improved hemodynamics as an induction agent: a randomized, controlled trial. J Trauma Acute Care Surg. 2012 Jul;73(1):94-101. doi: 10.1097/TA.0b — View Citation
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | Percent of Subjects With a Greater Than 20% Decrease in Systolic Blood Pressure (SBP) Following Induction of General Anesthesia | Blood pressure was recorded every minute for a total of 30 minutes after anesthesia was induced and readings were captured via a Non-Invasive Cardiac Output Monitor [NICOM], Cheetah Medical, Israel. The percentage of subjects experiencing decreases in SBP of greater than 20% during the specified time intervals is reported, as compared to the baseline systolic blood pressure reading. There are two numbers in a blood pressure reading, and they are expressed in millimeters of mercury (mm Hg). This tells how high in millimeters the pressure of your blood raises a column of mercury. The numbers usually are expressed in the form of a fraction; an example of a blood pressure reading is 120/80 mm Hg. The first, or top, number (120 in the example) is the systolic pressure. The systolic pressure is the measure of your blood pressure as the heart contracts and pumps blood. | Baseline, 5 minutes, 10 minutes, 30 minutes post induction | Yes |
Secondary | Percent of Subjects With a Greater Than 20% Decrease in Diastolic Blood Pressure (DBP) Following Induction of General Anesthesia | Blood pressure was recorded every minute for a total of 30 minutes after anesthesia was induced and readings were captured via a Non-Invasive Cardiac Output Monitor [NICOM], Cheetah Medical, Israel. The percentage of subjects experiencing decreases in DBP of greater than 20% during the specified time intervals is reported, as compared to the baseline DBP reading. The second or lower number of a blood pressure reading is the DBP and is the measure taken when your heart is at rest. | Baseline, 5 minutes, 10 minutes, 30 minutes post induction | Yes |
Secondary | Percent of Subjects With a Greater Than 20% Decrease in Mean Arterial Pressure (MAP) Following Induction of General Anesthesia | MAP was recorded every minute for a total of 30 minutes after anesthesia was induced and readings were captured via a Non-Invasive Cardiac Output Monitor [NICOM], Cheetah Medical, Israel. The percentage of subjects experiencing decreases in MAP of greater than 20% during the specified time intervals is reported, as compared to the baseline MAP reading. | Baseline, 5 minutes, 10 minutes, 30 minutes post induction | Yes |
Secondary | Average Change in Cardiac Output (CO) | CO was recorded every minute for a total of 30 minutes after anesthesia was induced and readings were captured via a Non-Invasive Cardiac Output Monitor [NICOM], Cheetah Medical, Israel. The average change in CO as compared to baseline CO during the specified time intervals is reported. CO is defined as the quantity of blood ejected per minute by the heart into the systemic circulation. It is the product of the heart rate (HR) (beats per minute) times the stroke volume (SV) (milliliters of blood ejected during each contraction). |
Baseline, 5 minutes, 10 minutes post induction | Yes |
Secondary | Average Change in Cardiac Index (CI) | CI was recorded every minute for a total of 30 minutes after anesthesia was induced and readings were captured via a Non-Invasive Cardiac Output Monitor [NICOM], Cheetah Medical, Israel. The average change in CI as compared to the baseline CI during the specified time intervals is reported. To determine CI, cardiac output is divided by the body surface area in order to account for body size. |
Baseline, 5 minutes, 10 minutes post induction | Yes |
Secondary | Average Change in Heart Rate (HR) | HR was recorded every minute for a total of 30 minutes after anesthesia was induced and readings were captured via a Non-Invasive Cardiac Output Monitor [NICOM], Cheetah Medical, Israel. The average change in HR (as compared to baseline HR) during the specified time intervals is reported. | Baseline, 5 minutes, 10 minutes post induction | Yes |
Secondary | Average Change in Systolic Blood Pressure (SBP) | Blood pressure was recorded every minute for a total of 30 minutes after anesthesia was induced and readings were captured via a Non-Invasive Cardiac Output Monitor [NICOM], Cheetah Medical, Israel. The average change in SBP (as compared to baseline SBP) during the specified time intervals is reported. | Baseline, 5 minutes, 10 minutes post induction | Yes |
Secondary | Average Change in Diastolic Blood Pressure (DBP) | Blood pressure was recorded every minute for a total of 30 minutes after anesthesia was induced and readings were captured via a Non-Invasive Cardiac Output Monitor [NICOM], Cheetah Medical, Israel. The average change in DBP (as compared to baseline DBP) during the specified time intervals is reported. | Baseline, 5 minutes, 10 minutes post induction | Yes |
Secondary | Average Change in Mean Arterial Pressure (MAP) | MAP was recorded every minute for a total of 30 minutes after anesthesia was induced and readings were captured via a Non-Invasive Cardiac Output Monitor [NICOM], Cheetah Medical, Israel. The average change in MAP from baseline during the specified time intervals is reported. MAP is a term used in medicine to describe an average blood pressure in an individual. It is defined as the average arterial pressure during a single cardiac cycle. |
Baseline, 5 minutes, 10 minutes post induction | Yes |
Secondary | Average Change in Total Peripheral Resistance (TPR) | TPR was recorded every minute for a total of 30 minutes after anesthesia was induced and readings were captured via a Non-Invasive Cardiac Output Monitor [NICOM], Cheetah Medical, Israel. The average change in TPR from baseline during the specified time intervals is reported. TPR is the overall resistance to blood flow through the systemic blood vessels. | Baseline, 5 minutes, 10 minutes post induction | Yes |
Secondary | Average Change in Total Peripheral Resistance Index (TPRI) | TPRI was recorded every minute for a total of 30 minutes after anesthesia was induced and results were captured via a Non-Invasive Cardiac Output Monitor [NICOM], Cheetah Medical, Israel. The average change in TPRI from baseline during the specified time intervals is reported. | Baseline, 5 minutes, 10 minutes post induction | Yes |
Secondary | Average Change in Stroke Volume (SV) | SV was recorded every minute for a total of 30 minutes after anesthesia was induced and results were captured via a Non-Invasive Cardiac Output Monitor [NICOM], Cheetah Medical, Israel. The average change in SV from baseline during the specified time intervals is reported. SV is the milliliters of blood ejected during each contraction of the heart. | Baseline, 5 minutes, 10 minutes post induction | Yes |
Secondary | Average Change in Stroke Volume Index (SVI) | SVI was recorded every minute for a total of 30 minutes after anesthesia was induced and results were captured via a Non-Invasive Cardiac Output Monitor [NICOM], Cheetah Medical, Israel. The average change in SVI (as compared to baseline SVI) during the specified time intervals is reported. To determine SVI, stroke volume is divided by the body surface area in order to account for body size. | Baseline, 5 minutes, 10 minutes post induction | Yes |
Secondary | Average Change in Stroke Volume Variation (SVV) | SVV was recorded every minute for a total of 30 minutes after anesthesia was induced and results were captured via a Non-Invasive Cardiac Output Monitor [NICOM], Cheetah Medical, Israel. SVV is a dynamic flow-based parameter and together with cardiac output provides an indication of fluid responsiveness. The average change in SVV (as compared to baseline SVV) during the specified time intervals is reported. SVV is calculated by taking the SVmax - SVmin /*100/ SV mean. | Baseline, 5 minutes, 10 minutes post induction | Yes |
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT03255187 -
Effect of Dietary Supplemental Fish Oil in Alleviating Health Hazards Associated With Air Pollution
|
N/A | |
Completed |
NCT05997303 -
Continuous Norepinephrine Administration and Blood Pressure Stability During Anesthetic Induction
|
N/A | |
Recruiting |
NCT04575194 -
Study of the Cardiometabolic Effects of Obesity Pharmacotherapy
|
Phase 4 | |
Completed |
NCT03918486 -
Caretaker vs. Routine Blood Pressure Sphygmomanometer
|
||
Completed |
NCT03410342 -
The Effects of Types of Fruits and Vegetables on Vascular Function
|
N/A | |
Active, not recruiting |
NCT05062161 -
Sleep Duration and Blood Pressure During Sleep
|
N/A | |
Not yet recruiting |
NCT04087070 -
Blood Pressure Estimation Using Noninvasive Biosignals During Pediatric Anesthesia
|
||
Completed |
NCT03294928 -
Arterial Waveform Analysis Applying Different Positive End-Expiratory Pressure (PEEP) Levels in Healthy Volunteers
|
N/A | |
Completed |
NCT03859934 -
Metabolic Effects of Melatonin Treatment
|
Phase 1 | |
Completed |
NCT03997461 -
Comparison of Arterial Tonometry Sensor With Standard Oscillometric Blood Pressure Monitoring Device
|
N/A | |
Completed |
NCT03290716 -
Diet, ExerCIse and carDiovascular hEalth (DECIDE) - Salt Reduction Strategies for the Elderly in Nursing Homes in China
|
N/A | |
Recruiting |
NCT06460233 -
Blood Pressure Changes After Bariatric Surgery
|
||
Recruiting |
NCT05196048 -
Blood Pressure Sensor of Watch-type Device With ECG Technology
|
||
Terminated |
NCT03325933 -
Resistance Training and Cardiometabolic Health
|
N/A | |
Not yet recruiting |
NCT06405880 -
Pharmacist Case Finding and Intervention for Vascular Prevention Trial
|
N/A | |
Completed |
NCT02924454 -
Effects of Lipid Emulsion on the Pharmacokinetic and Pharmacodynamic Properties of Metoprolol.
|
Phase 4 | |
Completed |
NCT02451059 -
Reducing Socioeconomic Disparities in Health at Pediatric Visits
|
N/A | |
Active, not recruiting |
NCT02670967 -
Effects of Soluble Fiber on Blood Pressure: A Meta-analysis of Randomly-controlled Trials
|
N/A | |
Completed |
NCT02239744 -
Intervention Study on the Health Impact of Air Filters in Chinese Adults
|
N/A | |
Completed |
NCT02271633 -
Nitrate Supplementation; Source
|
Phase 4 |