Biliary Stricture Clinical Trial
Official title:
Evaluation of the Utility of Single-operator Digital Cholangioscopy During Endoscopic Retrograde Cholangiopancreatography in the Diagnosis of Malignant and Benign Biliary Strictures
Differentiation between malignant and benign biliary strictures can be challenging. Accurate differentiation of malignant biliary strictures from benign ones is crucial to guide management decisions. While conventional tissue acquisition techniques such as brush cytology or intraductal biopsy of the biliary stricture is often performed during ERCP for tissue diagnosis, their sensitivities are suboptimal. The average sensitivities for brush cytology and intraductal biopsy were reported to be ~ 59% and ~ 63% respectively. When the cause of a biliary stricture remains unclear despite conventional ERCP techniques for diagnosis, cholangioscopy is often performed during ERCP to clarify the diagnosis. This allows an endoscopist to obtain a visual impression (VI) and to perform targeted biopsy under direct visualization of the biliary stricture. Recently, a digital SOC system (SpyGlass Digital System (SpyGlass DS), Boston Scientific, USA) has become available and has the potential to further improve the diagnosis of malignant and benign biliary strictures. The utility of this digital SOC in the evaluation of biliary strictures has not been well studied. We propose this study to evaluate the utility of the digital SOC during ERCP in the diagnosis of malignant and benign biliary strictures.
Status | Recruiting |
Enrollment | 40 |
Est. completion date | December 31, 2024 |
Est. primary completion date | December 31, 2024 |
Accepts healthy volunteers | No |
Gender | All |
Age group | 18 Years and older |
Eligibility | Inclusion Criteria: - Age = 18 years - Patients presenting with obstructive jaundice with clinical suspicion for a biliary stricture based on imaging findings or during ERCP - Written informed consent available Exclusion Criteria: - Contraindications for endoscopy due to comorbidities - Unable to provide written informed consent - Patients with clinical evidence of ongoing cholangitis precluding a safe cholangioscopy procedure - Pregnant patients - Moribund patients from terminal illnesses |
Country | Name | City | State |
---|---|---|---|
Hong Kong | Prince of Wales Hospital, The Chinese University of Hong Kong | Sha Tin | New Territories |
Lead Sponsor | Collaborator |
---|---|
Chinese University of Hong Kong |
Hong Kong,
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | sensitivity, specificity, and accuracy of the digital SOC during ERCP in the diagnosis of malignant and benign biliary strictures. | To assess the sensitivity, specificity, and accuracy of digital SOC in the diagnosis of biliary strictures | Till a diagnosis of a malignant stricture is made, or follow up period of at least 6 months for presumed benign stricture |
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT03115411 -
Prospective Evaluation of Winged Biliary Stent Patency in Patients With Benign Biliary Obstruction
|
N/A | |
Completed |
NCT02041390 -
Effect of Short Message Service Intervention on Stent Removal/Exchange Adherence in Patients With Benign Pancreaticobiliary Diseases
|
N/A | |
Recruiting |
NCT01439698 -
Radio Frequency Ablation in the Management of Pancreatico-biliary Disorders: A Multicenter Registry
|
N/A | |
Terminated |
NCT01413386 -
Efficacy and Safety of the Paclitaxel Eluting Covered Biliary Stent to the Common Covered Metallic Biliary Stent
|
N/A | |
Completed |
NCT01543256 -
WallFlex Biliary Fully Covered (FC) Chronic Pancreatitis Study
|
N/A | |
Enrolling by invitation |
NCT04572711 -
Prospective Evaluation of Biliary Tissue Sampling With ERCP
|
||
Recruiting |
NCT03229655 -
Evaluation of Sequential Stent Addition vs. Incremental Dilation & Stent Exchange for Management of Anastomotic Biliary Strictures After Liver Transplantation
|
N/A | |
Completed |
NCT02916199 -
Primary Needle Knife Fistulotomy Versus Conventional Cannulation Method
|
N/A | |
Recruiting |
NCT01522573 -
T-EUS for Gastrointestinal Disorders: A Multicenter Registry
|
N/A | |
Recruiting |
NCT01524146 -
Photodynamic Therapy (PDT) Cholangiocarcinoma Registry
|
N/A | |
Completed |
NCT02281019 -
SpyGlass AMEA Registry
|
||
Recruiting |
NCT04010734 -
Primary Cholangioscopy Versus ERCP in the Diagnosis of Biliary Strictures
|
N/A | |
Not yet recruiting |
NCT06369896 -
Digital Single-operator Cholangioscopy and Intraductal Ultrasound for Nonicteric Biliary Strictures
|
||
Recruiting |
NCT04391153 -
FISH in Diagnosis of Biliary Stricture
|
N/A | |
Active, not recruiting |
NCT03997994 -
DIGEST I Drug Coated Balloon for Biliary Stricture
|
N/A | |
Enrolling by invitation |
NCT03951324 -
Volumetric Laser Endomicroscopy's (VLE) Diagnostic Accuracy Validation Study: Impact on Clinical Management Study
|
||
Unknown status |
NCT01085747 -
Endoscopic Treatment of Biliary Stricture Caused by Chronic Pancreatitis
|
N/A | |
Completed |
NCT02105181 -
Fully Covered Self-expandable Metal Stents (FCMS) in Benign Biliary Strictures
|
N/A | |
Recruiting |
NCT05761483 -
Endoscopic Management of Non-anastomotic Biliary Strictures Following Liver Transplantation.
|
||
Completed |
NCT03673033 -
Biliary Complications in Live Donor Liver Transplantation
|