Clinical Trials Logo

Clinical Trial Summary

Differentiation between malignant and benign biliary strictures can be challenging. Accurate differentiation of malignant biliary strictures from benign ones is crucial to guide management decisions. While conventional tissue acquisition techniques such as brush cytology or intraductal biopsy of the biliary stricture is often performed during ERCP for tissue diagnosis, their sensitivities are suboptimal. The average sensitivities for brush cytology and intraductal biopsy were reported to be ~ 59% and ~ 63% respectively. When the cause of a biliary stricture remains unclear despite conventional ERCP techniques for diagnosis, cholangioscopy is often performed during ERCP to clarify the diagnosis. This allows an endoscopist to obtain a visual impression (VI) and to perform targeted biopsy under direct visualization of the biliary stricture. Recently, a digital SOC system (SpyGlass Digital System (SpyGlass DS), Boston Scientific, USA) has become available and has the potential to further improve the diagnosis of malignant and benign biliary strictures. The utility of this digital SOC in the evaluation of biliary strictures has not been well studied. We propose this study to evaluate the utility of the digital SOC during ERCP in the diagnosis of malignant and benign biliary strictures.


Clinical Trial Description

Differentiation between malignant and benign biliary strictures can be challenging. Accurate differentiation of malignant biliary strictures from benign ones is crucial to guide management decisions. While a mass lesion involving the bile duct may be observed on imaging such as ultrasound (USG), computed tomography (CT), or magnetic resonance imaging (MRI) in patient presenting with obstructive jaundice, early malignancy of the bile duct may often present with a ductal stricture without an obvious mass on imaging. Diagnosis of early stage malignancy of the bile duct is desirable since the lesion may be amenable to surgical resection of curative intent. Endoscopic retrograde cholangiopancreatography (ERCP) is an important diagnostic and therapeutic endoscopic technique in patients with obstructive jaundice and a suspected biliary stricture. While conventional tissue acquisition techniques such as brush cytology or intraductal biopsy of the biliary stricture is often performed during ERCP for tissue diagnosis, their sensitivities are suboptimal. The average sensitivities for brush cytology and intraductal biopsy were reported to be ~ 59% and ~ 63% respectively. When the cause of a biliary stricture remains unclear despite conventional ERCP techniques for diagnosis, cholangioscopy is often performed during ERCP to clarify the diagnosis. Cholangioscopy performed during ERCP involves passing a small scope (~ 10 French in size) through the working channel of the ERCP duodenoscope for direct visualization of the bile duct mucosa. This allows an endoscopist to obtain a visual impression (VI) and to perform targeted biopsy under direct visualization of the biliary stricture. The VI of a malignant biliary stricture is often characterized by the presence of intraductal abnormal tissue growth, and dilated, irregular, tortuous tumor vessels. During standard ERCP, cholangioscopy can be performed using a 2-operator "mother-baby" system, or a single-operator system. While the 2-operator "mother-baby" cholangioscopy technique can provide good image quality of the biliary stricture during ERCP, its use has been limited due to the cumbersome nature of the procedure requiring 2 endoscopists and the relative fragility of the video cholangioscope. Single-operator cholangioscopy (SOC) system, such as the SpyGlass Direct Visualization System, on the other hand allows a single operator to perform cholangioscopy during ERCP. In a recent meta-analysis of the studies using the optical fiber based SOC in the evaluation of indeterminate biliary strictures, the combined sensitivity and specificity of VI were 90% and 87% respectively, and the combined sensitivity and specificity of cholangioscopy directed biopsy were 69% and 98% respectively. The overall incidence of procedure-related adverse event (eg, infection, perforation, pancreatitis, etc) was reported to be 7.5% for diagnostic SOC during ERCP. Despite the promising results of VI using the optical fiber based SOC from prior studies, the actual image quality in daily clinical practice is frequently regarded as fair only due to the use of a small optical fiber for imaging, and gradual loss of resolution over time from optical fiber damage. A SOC with better image quality is needed for better endoscopic diagnosis of a biliary stricture. Recently, a digital SOC system (SpyGlass Digital System (SpyGlass DS), Boston Scientific, USA) has become available and has the potential to further improve the diagnosis of malignant and benign biliary strictures. The utility of this digital SOC in the evaluation of biliary strictures has not been well studied. We propose this study to evaluate the utility of the digital SOC during ERCP in the diagnosis of malignant and benign biliary strictures. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT03307382
Study type Interventional
Source Chinese University of Hong Kong
Contact Thomas Lam, BS
Phone 852-3505-3509
Email thomaslam@cuhk.edu.hk
Status Recruiting
Phase N/A
Start date December 15, 2015
Completion date December 31, 2024

See also
  Status Clinical Trial Phase
Completed NCT03115411 - Prospective Evaluation of Winged Biliary Stent Patency in Patients With Benign Biliary Obstruction N/A
Completed NCT02041390 - Effect of Short Message Service Intervention on Stent Removal/Exchange Adherence in Patients With Benign Pancreaticobiliary Diseases N/A
Recruiting NCT01439698 - Radio Frequency Ablation in the Management of Pancreatico-biliary Disorders: A Multicenter Registry N/A
Terminated NCT01413386 - Efficacy and Safety of the Paclitaxel Eluting Covered Biliary Stent to the Common Covered Metallic Biliary Stent N/A
Completed NCT01543256 - WallFlex Biliary Fully Covered (FC) Chronic Pancreatitis Study N/A
Enrolling by invitation NCT04572711 - Prospective Evaluation of Biliary Tissue Sampling With ERCP
Recruiting NCT03229655 - Evaluation of Sequential Stent Addition vs. Incremental Dilation & Stent Exchange for Management of Anastomotic Biliary Strictures After Liver Transplantation N/A
Completed NCT02916199 - Primary Needle Knife Fistulotomy Versus Conventional Cannulation Method N/A
Recruiting NCT01522573 - T-EUS for Gastrointestinal Disorders: A Multicenter Registry N/A
Recruiting NCT01524146 - Photodynamic Therapy (PDT) Cholangiocarcinoma Registry N/A
Completed NCT02281019 - SpyGlass AMEA Registry
Recruiting NCT04010734 - Primary Cholangioscopy Versus ERCP in the Diagnosis of Biliary Strictures N/A
Not yet recruiting NCT06369896 - Digital Single-operator Cholangioscopy and Intraductal Ultrasound for Nonicteric Biliary Strictures
Recruiting NCT04391153 - FISH in Diagnosis of Biliary Stricture N/A
Active, not recruiting NCT03997994 - DIGEST I Drug Coated Balloon for Biliary Stricture N/A
Enrolling by invitation NCT03951324 - Volumetric Laser Endomicroscopy's (VLE) Diagnostic Accuracy Validation Study: Impact on Clinical Management Study
Unknown status NCT01085747 - Endoscopic Treatment of Biliary Stricture Caused by Chronic Pancreatitis N/A
Completed NCT02105181 - Fully Covered Self-expandable Metal Stents (FCMS) in Benign Biliary Strictures N/A
Recruiting NCT05761483 - Endoscopic Management of Non-anastomotic Biliary Strictures Following Liver Transplantation.
Completed NCT03673033 - Biliary Complications in Live Donor Liver Transplantation