Clinical Trial Summary

Patients presenting to the emergency department (ED) may require breathing support with machines depending on the condition. Throughout the breathing support, the settings on the breathing machines will be tailored to the patient's requirements. These settings are manually adjusted by trained physicians. Currently, there are machines which can automatically change the settings based on real-time specific information obtained from the patient. This study aims to compare the use of machines which require manual adjustments (open-loop conventional ventilators) and machines which can automatically change the settings (closed-loop automated ventilators). Patients will be carefully selected to ensure no harm is caused whilst delivering the best care. This study will look into the duration when patients are receiving optimum settings and levels of oxygen and carbon dioxide in the blood. The outcomes of this study would allow us to identify methods to improve patient care.


Clinical Trial Description

Invasive mechanical ventilation is a lifesaving intervention for patients with respiratory failure in the emergency department (ED). Recent technological advancements have introduced closed-loop automated ventilators as a potential alternative to open-loop conventional ventilators. However, the efficacy and safety of closed-loop automated ventilators in the emergency setting remains understudied. This research aims to evaluate the efficacy and safety of closed-loop automated ventilator compared to open-loop conventional ventilator in intubated and ventilated patients in the ED. A randomized controlled trial will be conducted in an ED of a tertiary university-affiliated hospital. Eligible patients are 18 years or older, decision made by treating physicians to intubate and mechanically ventilate. Some of exclusion criteria are pregnancy, heart failure, metabolic acidosis, circulatory shock, life-threatening asthma and morbid obesity. The primary measure of efficacy is the duration of ventilation within a predefined range of acceptable respiratory parameters between automated and conventional ventilation. Secondary outcome measures are; number of manual adjustments required to attain targeted settings in automated and conventional ventilators, PaO2/FiO2 ratio (PF ratio), arterial blood gas results, vital signs, breath-by-breath analysis, and rate of ventilator dyssynchrony. The ventilator used in the intervention arm is the closed-loop automated ventilator Hamilton C6s INTELLIVENT-ASV (Hamilton Medical AG, Switzerland). Hamilton C1 ASV is chosen as the open-loop conventional comparator as it is similar to Hamilton C6s INTELLIVENT-ASV, without the INTELLIVENT software. Based on Lellouche et al, the calculated total sample size with a dropout rate of 10% is 132. The data is analysed based on the intention-to-treat (ITT) and per-protocol (PP) principles. The primary endpoint measurements are reported as areas under the curves (AUC) within the predefined range of acceptable respiratory parameters. Between-group differences in continuous variables are analysed using independent t-test or Mann-Whitney U test. Between-group differences in categorical variables are analysed using chi-square test. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT06157073
Study type Interventional
Source University of Malaya
Contact Dr Muhaimin, MMed
Phone +60173600157
Email muhaimin@um.edu.my
Status Not yet recruiting
Phase N/A
Start date January 1, 2024
Completion date December 31, 2025

See also
  Status Clinical Trial Phase
Completed NCT04435613 - Clinical and Physiological Assessment of a Nearly Ultra-protective Lung Ventilation Strategy: A Quasi-experimental Preliminary Study in ARDS Patients N/A
Enrolling by invitation NCT05020210 - Effect of Early Treatment With Sivelestat Sodium in ARDS Patients
Completed NCT04468971 - REgulatory T Cell infuSion fOr Lung Injury Due to COVID-19 PnEumonia Phase 1
Completed NCT04505592 - Tenecteplase in Patients With COVID-19 Phase 2
Completed NCT04493242 - Extracellular Vesicle Infusion Treatment for COVID-19 Associated ARDS Phase 2
Withdrawn NCT04909879 - Study of Allogeneic Adipose-Derived Mesenchymal Stem Cells for Non-COVID-19 Acute Respiratory Distress Syndrome Phase 2
Completed NCT02265198 - Relationship of Pulmonary Contusion to Pulmonary Inflammation and Incidence of Acute Respiratory Distress Syndrome N/A
Completed NCT01949272 - Optimization of PEEP for Alveolar Recruitment in ARDS N/A
Not yet recruiting NCT01668368 - Goal Directed Mechanical Ventilation Aimed at Optimal Lung Compliance N/A
Completed NCT01881061 - Lung Sonography in Patients With Acute Respiratory Distress Syndrome in Intensive Care Unit N/A
Completed NCT00808691 - Microcirculation and Oxidative Stress in Critical Ill Patients in Surgical Intensive Care Unit N/A
Completed NCT05035589 - The Effect of Tocilizumab on Procalcitonin and Other Biochemical and Clinical Markers in the Setting of COVID-19 Pneumonia
Recruiting NCT04764032 - Right Ventricular Dysfunction in Ventilated Patients With COVID-19
Completed NCT04556513 - Functional Recovery From Acute Respiratory Distress Syndrome (ARDS) Due to COVID-19: Influence of Socio-Economic Status
Recruiting NCT06036056 - NMR Based Metabolomics Kinetics in ARDS Patients
Recruiting NCT04503876 - Effects of End-expiratory Positive Pressure Optimization in Intubated Patients With Healthy Lung or Acute Respiratory Distress Syndrome N/A
Recruiting NCT04643691 - Losartan and Spironolactone Treatment for ICU Patients With COVID-19 Suffering From ARDS Phase 2
Completed NCT04395911 - Safety and Efficacy of SCD in AKI or ARDS Patients Associated With COVID-19 Infections N/A
Not yet recruiting NCT05341687 - Prognostic Value of Respiratory System Compliance Under VV-ECMO on 180-day Mortality in COVID-19 ARDS.
Recruiting NCT05056090 - Effect of Prone Positioning on Mortality in Patients With Mild to Moderate Acute Respiratory Distress Syndrome. N/A